NC505ES Remote LCD Receiver
Installation & Operating Instructions
Contents
Chapter 1-Introduction ..................................................... 1
About This Manual .........................................................1
Theory of Operation ........................................................1
What's in the Box ............................................................3
Features ...........................................................................3
Chapter 2-Installation ...................................................... 3
Mounting ........................................................................3
Connections ....................................................................3
Chapter 3-Programming & Operation ............................ 4
Receiver Menus ...............................................................4
Program Relay Outputs ...................................................4
Change Password ............................................................5
Monitor Signal Strength ..................................................5
Set up Transmitter Points 1-16 ........................................5
Point Status .....................................................................6
Event Log ........................................................................6
Alarms and Faults ............................................................6
Appendix-Device Specifications ..................................... 6
Illustrations
Figure 2-Inside the NC505ES ........................................2
Figure 3-Wiring Examples .............................................2

Figure 1-NC505ES Remote LCD Receiver

ALPHA COMMUNICATIONS
Toll-Free Technical Line: 1-800-666-4800
Website: www.AlphaCommunications.com
The NC505ES Remote LCD Receiver allows users of the
Tek-CARE
external dome lamps and dialers to the system. This provides an
alternate annunciation path, in addition to the normal Tek-
®
CARE
500 screen. The NC505ES is not dependent upon the Tek-
®
CARE
500's master station computer. It features 6 separate, dry-
contact outputs that can be programmed for activation of up to 16
unit addresses (transmitters) on the Tek-CARE
The NC505ES is programmed using its buttons and display, and
has an access code to safeguard completed programming. The
case has built-in tamper detection outputs for connection to an
external alarm system. All dry contact outputs are individually
configurable for latching, follower or momentary activation. The
NC505ES is designed for indoor use only, and cable access and
connections are hidden. The face of the unit features a clean
appearance with visual indication of the status of all 6 outputs.
This manual is designed to assist with installation of this
TekTone product. Each component of the system is described
with step-by-step instructions to facilitate hardware installation
and software configuration.
1. Although this is a low voltage unit, take care on wire
2. Remove power when installing cabling.
3. Use ESD wrist strap when installing cables.
1. Use proper splicing techniques.
2. Verify proper polarity of wires.
3. Use protective eyewear when clipping leads.
In a facility with a Tek-CARE
the NC505ES Remote LCD Receiver may be used to activate a
local dialer or turn on a corridor dome light in response to a call.
Note: Central Monitoring is a feature of the Tek-CARE
The NC505ES is configured locally to an area covering up to 16
transmitters and 6 relay outputs. Multiple units are used to
provide full coverage of a floor or building. The NC505ES
accepts transmissions only from transmitters, and does not
accept signals that are rebroadcast. Therefore the NC505ES
must be near the devices that it is to receive signals from.
®
• 42 Central Drive • Farmingdale, NY 11735-1202
Phone: (631) 777-5500
Email: info@alphacommunications.com

Chapter 1-Introduction

®
500 Wireless Emergency Call System to connect

About This Manual

termination at transformer and mains line outlet.

Theory of Operation

®
500 wireless emergency call system,
Fax: (631) 777-5599
IL882
Section E
Rev. 2 - 06 /2011
®
500 system.
®
500 system.

Advertisement

loading

Summary of Contents for Alpha Communications TekTone NC505ES

  • Page 1: Table Of Contents

    Therefore the NC505ES must be near the devices that it is to receive signals from. ALPHA COMMUNICATIONS ® • 42 Central Drive • Farmingdale, NY 11735-1202 •...
  • Page 2: Figure 2-Inside The Nc505Es

    Figure 2—Inside the NC505ES A - HOUSING RELEASE TAB B - POWER C - GND D - POWER LOSS OUTPUT E - RESET INPUT COM 1 F - TAMPER OUTPUT G - JAM OUTPUT H - OUTPUT TERMINALS I - FREQUENCY SELECT COM 2 COM 3 POWER...
  • Page 3: What's In The Box

    Select the Frequency Band What’s in the Box The NC505ES Remote LCD Receiver can use a range of • 2 pan head screws radio frequencies, and must be configured for your • 2 plastic anchors geographic area. To configure the receiver: •...
  • Page 4: Chapter 3-Programming & Operation

    Toggle—The relay output changes state each time the device Chapter 3—Programming & Operation sends a new activation. A minimum of five seconds must elapse before the relay output can send a new activation. Receiver Menus • Press the button to select this option. The ENTER There are three main menus (see Figure 5): display shows INACTIVE.
  • Page 5: Change Password

    Change Password Set up Transmitter Points 1–16 Passwords can be up to eight digits long. The default password Caution: When programming points, be careful not to map is 3446. To change the password: faults to the same output as alarms. 1.
  • Page 6: Point Status

    Low Bat Out—Maps transmitter/repeater low battery fault Event Log output. 1. From the READY, ALARM or FAULT prompts, press the • Use the buttons to scroll through the output DOWN button. ENTER numbers. Choose - - to disable low battery output. •...