Page 1
MAINTENANCE MANUAL Read this manual BEFORE using this product and retain it in case it is needed Version 1 Edition – August 2022 Stamp and signature of dealer Label Serial no. 7 Rue du Pont, 21450 Billy-Lès-Chanceaux, France | +33 (0)3 80 96 54 65 | export@benoitsystemes.com WWW.BENOITSYSTEMES.COM...
Page 2
Serial number In some situations, the required conditions must take into account all the factors for which the Mobili Kit motor unit provides a Indoor use relevant response. A PM&R physician (Physical Medicine and Rehabilitation), assisted by an occupational therapist or physiotherapist,...
PLATFORM Safety information about modifications made to the equipment ......16 Mobili Kit can be adjusted in three directions: front, back and depth. In this way, the Safety information about using the battery and charger ..........17 equipment's dimensions can be altered to adapt and adjust it to different sized chairs (a chair with 4 separate legs must be chosen).
Page 4
The Mobili Kit control unit controls direction, speed and jack of the motorised chair. It Mobili Kit is fitted with two independent motors, one on each front wheel, managed electronically by connection to a control unit can be fitted on the right or left and is height-adjustable.
To move, just push the joystick in the direction you want to go. The joystick's distance from its neutral position determines the Never wash your Mobili Kit using a hose or pressure washer. speed and radius of curvature of movement.
TROUBLESHOOTING The control unit dashboard is not lit or flashes Maintenance and inspection programme Daily* Monthly Quarterly Annually Possible causes Solutions If necessary, check the battery charge indicator and the Battery incorrectly locked in place Slightly remove the battery and re-engage it, then position the elastic charger Cable of the control unit poorly connected Check that the joystick on the control unit is neither...
TRANSPORT AND STORAGE JOYSTICK FAULT CODE INDICATOR CONTROL UNIT Follow these instructions: TRANSPORT • We recommend storing the motor unit at a temperature of There follows a reminder so that you can keep the adjustment 15°C and avoid extreme temperatures in order to extend the VR2 joystick fault code indicator procedures for each chair used, in which you'll find the service life of the motor unit and batteries.
SAFETY AND HAZARD INSTRUCTIONS SAFETY INFORMATION ABOUT THE ELECTRICAL SYSTEM WARNING SAFETY RECOMMENDATIONS ABOUT ELECTROMAGNETIC Risk of damage to the equipment or serious, even fatal, injury General safety instructions COMPATIBILITY WARNING Inappropriate use of the motorised chair can result in smoke or sparks being emitted, and heat may be given off.
• Do not exceed the maximum total permitted load (refer to users/carers or by unqualified technicians are liable to result in above 40°C. Mobili Kit with the battery unit fitted to moisture (water, the Technical Specifications section). damage to the equipment or serious, even fatal, injuries.
Risk of corrosion and burns from a leak of acid if the batteries are damaged. • Immediately take off any clothing soiled by the acid. MODEL MOBILI KIT • In the event of contact with the skin, immediately wash the affected area thoroughly with water. SERIAL NUMBER •...
Page 11
This medical device is a regulated healthcare product that bears CE marking under these regulations. As manufacturer, Benoît Systèmes declares that this product is a Class I device complying with the safety and performance requirements or European Regulation (EU) No 2017/745 on medical devices. 7 Rue du Pont, 21450 Billy-Lès-Chanceaux, France | +33 (0)3 80 96 54 65 | export@benoitsystemes.com WWW.BENOITSYSTEMES.COM...
Need help?
Do you have a question about the Mobili Kit and is the answer not in the manual?
Questions and answers