Sylvania Wide Vapor Tight 1A Installation Manual
Sylvania Wide Vapor Tight 1A Installation Manual

Sylvania Wide Vapor Tight 1A Installation Manual

Luminaires

Advertisement

Available languages

Available languages

www.sylvania.com
SYLVANIA Luminaires
Installation Guide – Wide Vapor Tight 1A
For warranty coverage, please register at www.sylvania.com/warrantyregistration.
PLEASE READ ALL INSTRUCTIONS BEFORE ATTEMPTING INSTALLATION
THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODES BY
A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS
INVOLVED. THIS PRODUCT MUST BE WIRED IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE AND
ALL APPLICABLE LOCAL CODES.
• TO PREVENT PERSONAL INJURY OR PRODUCT DAMAGE ONLY LICENSED ELECTRICIANS SHOULD
PROVIDE ALL INSTALLATION SERVICES.
• TO AVOID ELECTRIC SHOCK OR COMPONENT DAMAGE DISCONNECT POWER BEFORE ATTEMPTING
INSTALLATION OR SERVICING.
• USE CAUTION WHEN HANDLING THIS PRODUCT DURING OR AFTER OPERATION AS IT MAY BECOME HOT
AND CAUSE BURNS. DISCONNECT PRODUCT AND ALLOW COOLING PRIOR TO SERVICING.
• ANY ALTERATION OR MODIFICATION OF THIS PRODUCT IS EXPRESSLY FORBIDDEN AS IT MAY CAUSE
SERIOUS PERSONAL INJURY, DEATH, PROPERTY DAMAGE AND/OR PRODUCT MALFUNCTION.
• TO PREVENT PRODUCT MALFUNCTION AND / OR ELECTRICAL SHOCK THIS PRODUCT MUST BE
PROPERLY GROUNDED.
• THIS LUMINAIRE IS DESIGNED TO OPERATE IN AMBIENT TEMPERATURES RANGING FROM -4°F TO +104°F
(-20°C TO +40°C). EMERGENCY BACK UP TEMPERATURE RANGE IS +32°F TO +104°F (0°C TO +40°C).
• THIS LUMINAIRE IS DESIGNED TO OPERATE IN DRY, DAMP, OR WET LOCATIONS
• MIN 90°C SUPPLY CONDUCTORS
• TO PREVENT WIRING DAMAGE OR ABRASION, DO NOT EXPOSE WIRING TO EDGES OF SHEET METAL OR
OTHER SHARP OBJECTS.
NOTE!
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:(1) this device
may not cause harmful interference, and (2) this device must accept any interference received, including interference
that may cause undesired operation.
Please visit
www.sylvania.com\fccpart15B
CAN ICES-005(B) \ NMB5(B)
Cet appareil est conforme aux dispositions de la partie 15 du règlement de la FCC. Son utilisation est assujettie aux
deux conditions suivantes : (1) ce dispositif ne doit pas causer d'interférence nuisible; et 2) ce dispositif doit accepter
toute interférence reçue, y compris celle qui pourrait causer un fonctionnement non désiré.
Veuillez visiter le site Web:
CAN ICES-005(B) \ NMB5(B)
49.84"
CAUTION – RISK OF FIRE
www.sylvania.com\fccpart15B
4.9"

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Wide Vapor Tight 1A and is the answer not in the manual?

Questions and answers

Summary of Contents for Sylvania Wide Vapor Tight 1A

  • Page 1 SYLVANIA Luminaires Installation Guide – Wide Vapor Tight 1A 4.9” 49.84” For warranty coverage, please register at www.sylvania.com/warrantyregistration. PLEASE READ ALL INSTRUCTIONS BEFORE ATTEMPTING INSTALLATION CAUTION – RISK OF FIRE THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODES BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
  • Page 2 Confidential – for internal use only Competitor Product Comparison SAFETY PRECAUTIONS: IMPORTANT: READ CAREFULLY BEFORE INSTALLING THE FIXTURE. RETAIN FOR FUTURE REFERENCE. GENERAL: Upon receipt of the fixture, thoroughly inspect for any freight damage which should be brought to the attention of the delivery carrier. TO AVOID ELECTRIC SHOCK OR COMPONENT DAMAGE DISCONNECT POWER BEFORE ATTEMPTING INSTALLATION OR SERVICING INSTALLATION: 1.
  • Page 3 Wiring Diagrams This fixture is compatible with 0-10V output dimming controls (please reference Dimmable Compatibility List LEDLUM012). To get to 0% light output (OFF) it is necessary to switch the input power to the LED drivers. Connect wall dimmer to dimming wires on driver. (See Wiring Diagram) Wiring Diagram CLEANING AND MAINTENANCE •...
  • Page 4 Guide d’installation – Luminaire étanche à la vapeur large 1A 4,9 po 49,84 po Pour la garantie, veuillez-vous enregistrer à www.sylvania.com/warrantyregistration. VEUILLEZ LIRE TOUTES LES DIRECTIVES AVANT DE DÉBUTER L’INSTALLATION ATTENTION – RISQUE D’INCENDIE CE PRODUIT DOIT ÊTRE INSTALLÉ EN RESPECTANT LES EXIGENCES DES CODES D’INSTALLATION APPLICABLES PAR UNE PERSONNE FAMILIÈRE AVEC LA CONSTRUCTION ET L’OPÉRATION DU PRODUIT AINSI...
  • Page 5 Confidential – for internal use only Competitor Product Comparison CONSIGNES DE SÉCURITÉ : IMPORTANT : BIEN LIRE LES DIRECTIVES AVANT D’INSTALLER LE LUMINAIRE. GARDER POUR RÉFÉRENCES FUTURES. GÉNÉRAL : lors de la réception du luminaire, bien inspecter pour s’assurer qu’aucun dommage n’est survenu pendant le transport et si c’est le cas, aviser le transporteur.
  • Page 6 Dessins de câblage Ce luminaire est compatible avec des contrôles de gradation 0-10V (veuillez consulter la liste de compatibilité de gradation LEDLUM012). Pour obtenir un flux lumineux à 0% (ARRÊT) il est nécessaire de transférer la puissance à l’entrée aux pilotes DEL. Connecter le gradateur mural aux fils de gradation du pilote (Voir le dessin de câblage) (+)ALIMENTATION NOIR...

Table of Contents