xpr PXP-CL-MF Operating And Assembly Manual

Electronic cabinet lock

Advertisement

Quick Links

PXP-CL-MF
OPERATING AND ASSEMBLY MANUAL

Table of Contents

1
About this document .................................................................................................................. 2
1.1 Warnings ....................................................................................................................................... 2
2
Safety ........................................................................................................................................... 2
2.1 Proper use ..................................................................................................................................... 2
2.2 Improper use ................................................................................................................................ 2
2.3 General safety instructions .......................................................................................................... 2
3 Product description .................................................................................................................... 3
3.1 Functional description .................................................................................................................. 3
3.2 Design ........................................................................................................................................... 4
3.3 Versions ........................................................................................................................................ 4
3.4 Technical data .............................................................................................................................. 5
3.5 Management accessories ............................................................................................................ 7
4 Assembly ..................................................................................................................................... 8
4.1 Assembly instructions .................................................................................................................. 8
4.2 Assembly ...................................................................................................................................... 8
5
Operation ..................................................................................................................................... 9
5.1 Automatic wake up ...................................................................................................................... 9
5.2 Opening the door ......................................................................................................................... 9
5.3 Toggling the cabinet lock ........................................................................................................... 10
5.4 Indications .................................................................................................................................. 10
6 Cleaning and maintenance ....................................................................................................... 11
6.1 Maintenance ................................................................................................................................ 11
7
Faults during operation ............................................................................................................. 13
7.1 Fault indications .......................................................................................................................... 13
8 Disassembly and Disposal ........................................................................................................ 14
8.1 Disassembly ................................................................................................................................ 14
8.2 Disposal ....................................................................................................................................... 14
9 Key Manager Software ............................................................................................................. 15
9.1 Initialization of PXP-CL-MF .......................................................................................................... 15
9.2 Clear PXP-CL-MF ......................................................................................................................... 16
9.3 Configure PXP-CY-MF.................................................................................................................. 16
9.4 Adding Card holders.................................................................................................................... 17
9.5 Downloading events and report viewing ................................................................................... 17
Electronic cabinet lock
www.xprgroup.com
EN
Rev. 1.01 - 03.11.2021
1

Advertisement

Table of Contents
loading

Summary of Contents for xpr PXP-CL-MF

  • Page 1: Table Of Contents

    8 Disassembly and Disposal ......................14 8.1 Disassembly ..........................14 8.2 Disposal ............................14 9 Key Manager Software ......................15 9.1 Initialization of PXP-CL-MF ......................15 9.2 Clear PXP-CL-MF ......................... 16 9.3 Configure PXP-CY-MF........................16 9.4 Adding Card holders........................17 9.5 Downloading events and report viewing ...................
  • Page 2: About This Document

    1 ABOUT THIS DOCUMENT This operation and assembly manual describes the electronic cabinet lock . It is part of the product and PXP-CL-MF con- tains important information that is necessary for proper operation and maintenance. This operating and assembly manual is valid for all versions of PXP-CL-MF and is intended for technicians responsible for assembling and disassembling, as well as for end customers.
  • Page 3: Product Description

    The reading unit, the communication electronics, the mechanical system and power supply, are integrated within the cabinet lock. Different transponder carriers can be used as key in the PXP-CL-MF, for example, ISO card or key fob. The PXP-CL-MF has the following system properties: •Up to 16,000 key/locking authorizations can be stored...
  • Page 4: Design

    3.2 Design 1. Mounting nut (Cabinetinet lock) 6. Mounting screw 2. Locking lever (has to be ordered separately) 7. Button for manual activation 3. Lock washer 8. Battery 4. Mounting nut (locking lever) 9. Battery compartment 5. Operating lever 3.3 Versions Different versions of the electronic locking cylinder are available for selection: - 3 versions of the locking lever Locking lever option 2...
  • Page 5: Technical Data

    3.4 Technical data 3.4.1 General technical data Description Value Dimensions 148.5 mm x 44.7 mm x 35 mm (H x W x D) (when installed) Door thickness up to 20 mm MIFARE® Classic Transponder MIFARE® DESFire ® Power supply Battery CR2 3V (2 units) Battery life up to 74,500 operations or 10 years 3.4.2 Ambient conditions...
  • Page 6: Management Accessories

    3.5 Management accessories 3.5.1 Key Manager The Key Manager management software helps easy management of the electronic locking system via the PC. The communication between the locking units and the management software takes place via programming cards or via USB radio stick. 3.5.2 PXP-RS-USB radio stick (optional) The USB Radio Stick is required for firmware upgrade.
  • Page 7: Assembly

    - Carry out the assembly necessarily with the door open. - Ensure that the latches or seals fitted to the door do not hinder the proper operation of the PXP-CL-MF. - Ensure that the cabinet lock does not protrude and prevent the door from swinging freely.
  • Page 8: Assembly

    4.1.3 Determining the opening direction The direction of rotation of the operating lever is determined by the position of the small screw on the mounting thread. - Opening by turning the operating lever to the left: - Opening by turning the operating lever to the right: 4.2 Assembly - Insert the cabinet lock through the holes in the door.
  • Page 9 - Mount the cabinet lock using the mounting nut and mounting screw. - Secure the locking lever and lock washer with the mounting nut (locking lever). - Check if the cabinet lock is functioning. www.xprgroup.com...
  • Page 10: Operation

    5 OPERATION 5.1 Waking up Automatic wake-up is disabled for the cabinet lock in the delivered condition. To check the authorisation of a key, it needs to be woken up from the sleep mode. - To wake-up the reading unit, press the button on the front of the cabinet lock until the LED glows. - Hold up the key in front of the reading unit only after this.
  • Page 11: Indications

    5.4 Indications Operation Signal (audible and visible) and explanation Rest mode No audible or visible signal Start of service mode Long audible signal followed by a short audible signal End of service mode Short audible signal followed by a long audible signal Read mode (after waking) Red LEDs are flashing...
  • Page 12 6 REPLACING THE BATTERY AND CLEANING 6.1 Replacing the battery - Open the battery compartment of the cabinet lock with the battery replacement tool. For this purpose, press the tool into the opening below the cabinet lock until the battery compartment can be removed. - Remove the used battery and insert the new battery, paying attention to the polarity.
  • Page 13: Faults During Operation

    7 FAULTS DURING OPERATION 7.1 Fault indications Operation Audible signal Explanation Memory fault / 5 long audible configuration fault signals, 1 brief audible signal Coupling error 5 long audible signals, 2 brief audible signals RTC fault (clock) 5 long audible signals, 3 brief audible signals...
  • Page 14: Key Manager Software

    5. Put the Initialization card on the USB Desktop Reader and click on “Initialization Card”. Wait for confirmation message - Initialization Card created. 6. Hold the card in front of PXP-CL-MF. If the initialization is good, you will hear 3 long beeps and 3 short beeps. The LED will be green long and red short in the end.
  • Page 15: Clear Pxp-Cl-Mf

    2. Configuration card tab. Click on “Clear Card”. Wait for confirmation message - Clear Card created. 3. Hold the card in front of PXP-CL-MF. If the clear procedure is good, you will hear 3 long beeps and 3 short beeps. The LED will be green long and red short in the end.
  • Page 16: Adding Card Holders

    2. Put the card on the USB desktop reader. Click on Create Collect events card (PXP). Wait for confirmation message - Card created. 3. Hold the card in front of PXP-CL-MF. Hold it longer than 5 seconds, until you will hear 3 long beeps and 3 short beeps. 4. Put the card back on the USB desktop reader.
  • Page 17 To obtain of the events already downloaded, go to Reports/ Event Report. Select the period and click on Load. Additional filtering can be done by time, door, event type, card holder... The reports can be exported in PDF or XLS. www.xprgroup.com...
  • Page 18 This product herewith complies with requirements of EMC directive 2014/30/EU, Radio Equipment Directive 2014/53/EU. In addition it complies with RoHS2 directive EN50581:2012 and RoHS3 Directive 2015/863/EU. www.xprgroup.com...

Table of Contents