Page 1
However, it is not possible to guarantee its accuracy and all liability is excluded. Cited companies and/ or product names are trademarks belonging to the respective companies. 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
Page 2
Ge n er al c a u t io nary notes a nd wa r nings • Never use the JJ-CCR Rebreather without receiving specific equipment training (basic course or crossover). It is essential receiving training from a factory ap- proved instructor and from a factory approved training agency.
Risks against which the PPE is intended to protect The JJ-CCR rebreather is a respiratory protective device intended for diving purposes only. The JJ-CCR rebreather make it possible to supply the user with a breathable gaseous mixture under foreseeable con- ditions of use and taking account in particular of the maximum depth of immersion.
Congratulations on purchasing the JJ-CCR Rebreather. We are certain that you will experience many un- forgettable dives using this equipment. The development and testing of the JJ-CCR Rebreather started back in 2006. During this period the equip- ment was able to demonstrate exceptional reliability over more than 1500 diving hours at a wide range of locations around the world prior the first public release.
• Independent HUD (Head Up Display) with real-time display of PPO2 for all three oxygen sensors. • Reliable controller with an integrated multi-gas decompression computer (based on the Shearwater Petrel 2). 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
Dives exceeding a depth of 100 m are associated with numerous additional risks Air: DIN EN 12021 Purity of the gases Oxygen: >99.5% (medicinal oxygen) Helium: >99.996 Atmospheric pressure range 800 – 1050mbar 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
Therefore it is not possible to specify exact numbers. 3.2.4 High-pressure oxygen The JJ-CCR uses high pressure oxygen as one of its supply gas mixtures. The related parts has been cleaned and prepared specifically for use with high-pressure oxygen. The diver must taken special care. Especially when filling the oxygen cylinder.
3.2.5 Expected inspired gas concentrations The oxygen setpoint range of the JJ-CCR is from 0.4 to 1.5 bar (low and high). The setpoint range cre- ates breathing gas mixture representing an inspired oxygen partial pressure between 0.4 bar and 1.5 bar.
Assembly of the JJ-CCR This chapter deals with the basic assembly of the JJ-CCR Rebreather. The equipment is fully assembled at the time of delivery. This chapter is primarily intended to show how the basic assembly takes place. At the same time, it acts as a guideline for correctly reassembling the equipment if it proves necessary to disassemble it for any reason (e.g.
The heavy duty stand is secured to the base plate of the base unit with 4 lock screws. The stand prevents the JJ-CCR from falling and can also be used as a fastening point for stages, wheels, buoys, etc. whilst diving.
The following im- age shows the stand correctly attached. All parts are shown once again here in overview. 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
The next assembly step concerns the 1st stages and hoses (low pressure and high pressure). When de- veloping the JJ-CCR, extensive value was placed on clear and simple hose guidance. A further primary objective was to ensure that the equipment was fitted with the minimum possible number of hoses.
ATTENTION: Never attempt to lift the equip- ment using the ADV or T-piece. This can cause serious damage to the counter lungs! 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
A washer and wing nut are attached to the backplate. From time to time it is necessary to check whether the wing nut requires tightening, or if it has loosened at all. 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
The harness is supplied fully assembled together with the back plate. However, it is essential that the harness is adjusted to the physical dimensions of the diver. The JJ-CCR Rebreather must always sit as high as possible on the diver’s back. It is also necessary to ensure that the equipment sits as tight to the back as possible.
Connecting the supplemental valves The JJ-CCR comes with two suplemental valves. The oxygen valve enables the manual supply of oxygen via the t-piece into the breathing circuit. The diluent valve enables the supply of diluent via a second con- nection on the ADV into the breathing circuit.
4.11 Soda lime canister (axial) The JJ-CCR Rebreather is supplied with an axial soda lime canister. 1. Take a water-resistant dust filter 2. Fill the soda lime canister until and place it in the base of the soda approx.
The soda lime canister is correctly filled if shaking it does not result in noise being heard from the soda lime. 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
Page 25
(T-piece) is anti clockwise. to the ADV! ATTENTION: Never attempt to lift the equipment using the ADV or T-piece. This can cause serious damage to the counter lungs! 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
O-rings on the breathing hose. Then push it into the retainer on the DSV. The JJ-CCR Rebreather is now fully assembled and the assembly chapter is hereby complete. For detailed information on the individual main components of the JJ-CCR Rebreather refer to the respective chapters.
Main components This chapter provides descriptions of some of the main components of the JJ-CCR Rebreather and also includes a few essential maintenance and care instructions. The lid with the three oxygen sensors, solenoid, battery com- partment, and connectors for controller and HUD is effec- tively the brain of the JJ-CCR Rebreather.
5.1.2 Oxygen sensors The JJ-CCR Rebreather uses three JJ-CCR oxygen sensors. The sensors can be exchanged in seconds with- out the use of a tool. The three cells are numbered (1, 2 and 3). These numbers can be found adjacent to the connection on the lid and above each cell.
5.1.3 Solenoid The JJ-CCR Rebreather uses a special solenoid, which is characterised in particular by its extremely low power consumption. With this solenoid the defective operating state is always in the closed position – this dramatically reduces the potential for oxygen poison- ing in the event of a malfunction.
For a detailed description of the controller refer to the chapter 6. HUD (Head Up Display) The JJ-CCR Rebreather is supplied as standard with an HUD (Head Up Display). The HUD functions fully independently of the controller. This means that it uses its own DiveCAN® bus, electronic and power supply.
A blinking LED is drawn with lines emanating from it. An LED that is on-steady is drawn solid. An off LED is not drawn. Red LED is blinking Green LED is on solid All other LEDs are off 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
If the buddy warning light comes on, check your PPO2, consult your handset, and deal with the problem. 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
When the wet contacts detect water, the button inputs are disabled. This is to prevent entering com- mands while diving. • If the button is not working, try rinsing in fresh water and then ensuring that the wet contacts are dry. 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
The HUD only calibrates at a PPO2 of 1.0 ata. This means it assumes pure oxygen is used for the calibra- tion, and it is performed at sea-level. 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
Battery is low and should be Replace the 3.6v Lithium Batterie (SAFT LS replaced 14500). Refer to chapter: 5.1.1 After turn on, the yellow row stays on for 30 seconds 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
HUD holder on the DSV is on the right side. This function is only useable, when some- body connects another DSV oder BOV to the JJ-CCR which allows to attach the HUD to the left side. 1. Turn the HUD on by pressing the button once.
HUD holder on the DSV is on the right side. This function is only useable, when some- body connects another DSV oder BOV to the JJ-CCR which allows to attach the HUD to the left side. The first image shows the standard HUD orientation on the JJ-CCR rebreather.
ADV (Automatic Diluent Valve) The JJ-CCR Rebreather is supplied with an ADV. The ADV works in a similar way to a 2nd stage and supplies additional diluent to the breathing circuit if necessary. This is the case for exam- ple if considerable negative pressure exists in the breathing cir- cuit.
Controller The JJ-CCR Rebreather is supplied with a controller, which contains a multigas (nitrox, trimix, heliox) and multimode (Open and Closed Circuit) dec (Open and Closed Circuit) decompression computer. The firmware installed on the controller is optimised for the JJ-CCR Rebreather and contains capabilities and functions developed specially for the equipment.
• Tilt compensated digital compass with multiple display options • Display can be rotated through 180 degrees • Bluetooth Dive log uploading to Shearwater Cloud • Bluetooth Firmware Updates 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
DiveCAN® Architecture DiveCAN® is a digital communications standard developed specifically for rebreathers. The JJ-CCR uses two independent DiveCAN® busses. The handset (controller) is connected via the control bus to the SOLO board (Solenoid and Oxygen controller). The HUD uses the monitor bus and is connected to the Oxygen board (OBOE).
To turn the controller on, press both the MENU (left) and the SELECT (right) buttons at the same time. The JJ-CCR logo appears for a brief time, following by the controller’s main display. JJ-CCR logo appears for a brief time, following by the controller’s main display.
SELECT (Right) button From main screen Steps through info screens In a menu Performs command or starts editing Editing a setting Save the setting’s value 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
The seconds display as a bar drawn below the word “Time.” It takes 15 sec- onds to underline each character in the word. Does not display the seconds bar when not diving. 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
Page 46
When deco clears the STOP DEPTH and TIME are replaced by a counter that OC 21/00 begins counting up from 0. GasPO2 O2/HE OC 21/00 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
If this occurs, follow the training guidelines from your training agency. When voting fails the decompression calculations use the PPO2 from the lowest sensor (most conservative value), down to a minimum PPO2 of 0.16. 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
NDL (see Dive Setup -> NDL Display). The options are: • Ceiling • @+5 • Delta+5 • GF99 • SurGF Each of these values is discussed further in the next section. 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
Page 49
1.23 1.25 1.27 1.23 1.25 1.27 1.23 1.25 1.27 Brightness Med AvgATM Error CONFIRM 6.76 MISSED DECO STOP Change Save Sample Info Screen Sample Menu Sample Warning 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
Pressing the MENU (left) button will return to the home screen at any time. The next section gives descriptions of the data elements shown on the info screens. 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
Page 51
Maximum Depth: The maximum depth of the current dive. When not diving, displays the maximum depth of the last dive. 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
Page 53
GF99 is displayed in when the current gradient factor modi- fied M-Value (GF High) is exceeded. GF99 is displayed in when 100% (un-modified M-Value) is ex- ceeded. 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
Page 54
For VPM-B, higher values are more conservative. If the deco model is VPM-B/GFS, also displays the gradient factor for VPM-BG +3/90 surfacing. For the gradient factor, higher values are less conservative. 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
Page 55
Each controller has a unique serial number. SERIAL NO VERSION The version number indicates the available features. The last two 9F1F0432 4800392 numbers are the firmware version (V92 in this image). 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
Page 56
Bühlmann’s original super-saturation lim- its). Also, this scale changes with depth, since the M-Value line also changes with depth 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
Page 57
(21% O , or Air) TISSUES After descent TISSUES On-gassing TISSUES Deep stop TISSUES Last deco stop Note: Gas is now 50% O and 50% N 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
PPO2 and gas values are highlighted and flash. High PPO2 1.62 These persistent notifications will clear automatically once a safe O2/HE PPO2 is restored. 21/40 0 56 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
Clear that notification by pressing any button to see the next notification. Contact Shearwater: The subsequent list of notifications is not exhaustive. Please contact Shearwater if you experience any unexpected errors: info@shearwater.com 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
Page 60
No Comms ---- ---- Alternates See the Transmitter Connection No communications for 90+ seconds Issues section for more informa- Warning Confirm tion. AI LOST COMMS 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
Page 61
Try the firmware upgrade again. Firmware update failed, possibly Error Confirm UPGRADE FAIL due to a communications error or Contact Shearwater if problem persists. corrupted file. 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
The compass automatically compensates for this angle. However, near the poles, the inclination angle can exceed 80° (i.e. the magnetic field points almost directly up or down), in which case the specified accuracy may not be met. 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
“Air Integration” features and functions. NOT SUPPORTED: The AI function is currently not supported by JJ-CCR ApS. The JJ-CCR rebreather is fully certified to a depth of 100 meters. Were as the controllers air integration system is under EN 250 certified for use with air only to a maximum depth of 50 meters.
If no buttons are pushed for 1 minute, the menu system will time-out, returning to the main screen. Any- thing that had been previously saved will be retained. Anything that was in the middle of editing will be discarded. 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
AI Setup BO Gases CC Gases O2 Setup only Surface Bus Devices Auto SP Switch Alerts Setup Display Setup Compass only System Setup Advanced Config 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
Important: The calibration gas must be set to 100% oxygen (see system setup – option ”Calibrate O2”) • In countries in which 100% oxygen is not available it is naturally necessary to use the respective oxygen content. 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
Page 67
7. After confirming the ”O2 Cal. Report” it switches back to the main display. O2 Cal. Report MILLIVOLTS 46.1 47.2 45.2 SUCCESS 1.00 .84 .84 .84 0.98(0.991mb) PPO2 = 0.98 Auto-calibration mV = 55, in progress Confirm 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
Page 68
• The oxygen sensors should be calibrated regularly. This should ideally take place prior to every dive and at least once daily with multiple dives. 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
6 metres with oxygen (= oxygen flush). The PPO2 should lie above 1.5 after this. If this is not the case, the oxygen sensors should be replaced. 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
During a dive the “Switch Setpoint” menu item will be the first item displayed, since the “Turn Off” and “Calibrate” displays are disabled when diving. 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
The separation of the two gas lists enables a simple open circuit (BO) bailout: The diver dives with the JJ-CCR Rebreather and has various stages throughout, at which he can switch to this in the event of a JJ-CCR Rebreather and has various stages throughout, at which he can switch to this in the event of a rebreather failure.
PPO2 less than 1.61). This reduces button presses in most cases. • On the surface or when no deco stops are needed, the first gas pointed to will be the active gas. 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
External PPO2 sensors readings will continue to be displayed so the user can monitor their loop PPO2 in case they need to return to the loop. 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
0.4. Press the right (Save) button to lock in new low setpoint. 6.20.2 Edit High SP (High Setpoint) Edit High SP Works in exactly the same way as the Edit Low Setpoint function above. Next Edit 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
The computer will display all 5 gas entries available to allow you to enter new gases. Pressing MENU one more time when the fifth gas is displayed will return you to the “Define Gas” menu item. 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
If you often use other gases, you can enter the gas and turn it off. You can turn gases on and off during a dive and you can also add or remove a gas during the dive if needed. 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
• The planner will use the configured last stop depth. • The RMV is the same during the bottom phase of the dive as it is while traveling and during deco 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
Page 78
Indicates the gas quantity in litres or cuft. This info is only displayed in the OC or BO plan. The CC plan does not display this information! Bottom Time Ascent Time 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
Page 79
(bailout in CC) will be reported. Depth Time RMV PO2 No Deco Stops. Total NDL at 24m is 30 minutes Bailout gas quantity is 73 Liters. Quit Done 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
Shows on the right side of the bottom row two additional pieces of custom information. It can be MINI configured from the “Setup Setup > Deco” configured from the “Setup Setup > Deco” 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
Next Regularly test vibration alerts with the Test Vibration tool to ensure they are working and you can hear/feel them through your exposure suit. 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
Scrolling past all screens of an individual log brings up the Edit Log page where Dive number, Date, and Time can be changed, or the dive log can be deleted. 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
“O2 Cal. History” sub-menus. While in restore mode, these records can be restored. The Delete All Logs option is also changed to Restore All Logs when Restore mode is enabled. 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
Fresh water setting. • The setting only has an impact for the displayed depth. It has no impact on the decompression calculation. 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
It is possible to set the last decompression stop at either 3 Buhlmann GF ZHL- 16C or 6 metres. Conserv 30/70 Last Stop NDL Display Clear Cntr Next Edit 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
When turned on, the counter will count up from zero in the deco area starting when decompression obligations are cleared. Conserv 30/70 Last Stop NDL Display Clear Cntr Next Edit 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
Set AI Mode to OFF when AI not in use! NOT SUPPORTED: The AI function is currently not supported by JJ-CCR ApS. The JJ-CCR rebreather is fully certified to a depth of 100 meters. Were as the controllers air integration system is under EN 250 certified for use with air only to a maximum depth of 50 meters.
”FAIL” appears on the display in place of a num- ber for all three sensors. PPO2 values are only displayed once again after Next Edit successful calibration! 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
The values 0.7 and 1.3 are shown as examples only. Other values for the low and high setpoint can be adjusted in the Dive Setup or Mode Setup menu. 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
Via this menu item it is possible to switch the temperature between ” ” ” °C °C Display Setup and ”°F”. and ”°F”. Depth Units Meters Temp. Units °C Brightness Auto Altitude Auto Flip Screen Next Edit 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
60°, so this may seem the most natu- ral. The 90° or 120° setting can be used to see a wider range. 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
+ 0° If matching an uncompensated compass, or navigation is based on relative 222° 222° directions, then this setting can be left at 0° Next Edit 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
Battery Info Regulatory Info Note: This will not affect other computer settings, delete dive logs, or Next Edit reset dive log numbers. 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
This section is where a user can find the specific model number of their Advanced Config computer as well as additional regulatory information. Edit Adv. Config Reset Adv. Config System Info Battery Info Regulatory Info Next View 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
Edit The battery icon displays always when on the surface. During Surf + Warn dive it displays only if there is a low battery warning. 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
This menu allows some fine tuning of button sensitivity. This can be useful Adv. Config 3 to adjust downward if you often experience accidental button presses. Button Sensivity Left Right Next Edit 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
.71 .73 .74 SRI Solo 2 example, on the SOLO board (solenoid and oxygen controller) the Solenoid Speed set- ting can be adjusted. Bus Devices Exit View 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
Solenoid speed setting can be set to either the 1 second or 5 second PID control algorithm. This feature is comparable with the “slow” and “fast” solenoid setting, which was available on the classic JJ-CCR is comparable with the “slow” and “fast” solenoid setting, which was available on the classic JJ-CCR (Shearwater Predator based controller).
Battery types that support the fuel gauge feature will give more warning before the computer dies. • Some battery types perform better in cold water. 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
The clock is also updated every time the dive computer is connected to Shearwater Cloud Desktop or The clock is also updated every time the dive computer is connected to Shearwater Cloud Desktop or Shearwater Cloud Mobile. Shearwater Cloud Mobile. 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
1. Click the connect icon to open the connect tab. 2. Scan for Dive Computer 3. Once you’ve connected the computer once, use the Petrel 3 tab to connect faster next time 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
Page 105
Update Start-up Image: Here you can also change the startup image that appears when the con- troller turns on to help better differentiate your dive computer. 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
In Shearwater Cloud Mobile: 1. Press the connect icon at the bottom of the screen 2. Select your Petrel 3 from the list of Bluetooth devices 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
Page 107
The controller screen will give percentile updates of receiving the firm- ware, and then the mobile app will read “Firmware successfully sent to the computer” on completion. 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
Checklist prior to diving This chapter contains a complete checklist for the JJ-CCR Rebreather prior to a dive. It is essential that the diver run through this checklist prior to every dive. • If the diver does not run through the checklist then there is a possibility of entering the water with equipment that is not suitable for diving, which can result in severe risks to health.
Check the display on the controller and HUD. Check that the equipment is correctly positioned and that everything is stored in the right place. 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
Diving The most important rule when diving is: Always know your PPO2 at all times! With the JJ-CCR this can be read out from the HUD and/or the controller. In order to be certain that both systems are working correct- ly, the diver should also check regularly to ensure that both instruments are displaying the same values.
Leave the lid and the soda lime canister to dry. Remove the counter lung with the breathing hose. Spray a little disinfectant (e.g. JJ-CCR Clean) into the T-pieces. Fill the counter lung and breathing hose with water and wait a few minutes (in accordance with the specifica- tions for the disinfectant).
Maintenance 12.1 General Care As with all technical equipment, the JJ-CCR Rebreather should always be treated with care. General care also includes observing the maintenance intervals and regularly checking the general condition of the equipment. For example, the O-ring grease.
If used within chlorinated water (swimming pool), it has to be cleaned with fresh water right away. 12.5 Maintenance Intervals The JJ-CCR Rebreather must be maintained in accordance with the maintenance intervals specified. • The user is permitted to replace the O-rings for the breathing circuit, the lid, base plate, shutter valves, oxygen sensors and membrane for the ADV.
Part or Assembly Maintenance Task Return the equipment to the manufacturer or an approved service centre JJ-CCR Rebreather for a general service. ALWAYS KNOW YOUR PO2 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
Page 115
WE ARE PROUD OF BEEING THE REBREATHER MANUFACTURER OF YOUR CHOICE! OUR TEAM INTEND TO SUPPORT YOU AS MUCH AS THEY CAN IN ORDER TO EXCEED YOUR EXPECTATIONS • • • 2022 JJ-CCR ApS – 3.00 / Revision 00 J J -CCR A pS 20 22...
Need help?
Do you have a question about the Rebreather DiveCAN and is the answer not in the manual?
Questions and answers