Motor Operator Instruction Manual
(Types): TPMC16S
TPMC25S
This device motorizes the breaker
RESET operation. It also allows you to operate the
breaker manually.
Please retain this manual for future reference. The Manufacturer assumes no responsibility for
damages resulting from non-application or incorrect application of the instructions provided herein.
6-13-47 Kamihigashi, Hiranoku, Osaka
〒547-0002
547-0002, Japan
大阪市平野区加美東6–13–47
TEL 06–6791–2756
TEL +81-6-6791-2763
FAX 06–6791–2732
FAX +81-6-6791-2732
http://www.terasaki.co.jp
http://www.terasaki.co.jp
kiki-info@terasaki.co.jp
int-sales@terasaki.co.jp
2G1463SAA KRB-0925
85% 110%
10
3
E
AC1500V 1
DC24V
AC500V 1
ON
SHT / UVT
TRIP
ON
ON
Applicable Breaker Types
Motor operator type
Applicable breaker types(3Pole, 4Pole only)
TPMC16S
PS50-
, PS125-
, P160
TPMC25S
PS250-
, P250
ON /
OFF ,
Packaged Items
Motor operator
Connector lever
Caution
Operation Precautions
Permissible ranges of operating voltage are as follow:
85 to 110% of the rated voltage
Undervoltage or overvoltage may cause burnout.
The motor is rated for short-time duty. Repeated
10
should not exceed 10 times. Otherwise, burnout could result.
Turn off the power immediately if motorized operation does not complete within 3
seconds. Otherwise, burnout could result.
The dielectric withstand voltage of the Motor Operator is 1500 VAC for one minute
between the control circuit group and terminal E. (For control voltage of 24 VDC, the
dielectric withstand voltage is 500 VAC for one minute.) Overvoltage may result in
damage to the Device.
Avoid actuating the Motor Operator while not yet installed to the breaker. Repeated
actuations of the Operator alone could cause malfunction.
Maintainance Precautions
Actuate the Motor Operator periodically (a few times a year). No actuation for a long time
could cause malfunction.
Other Precautions
The motorized operation is possible only at the time of the illumination of the power
indicator. Light up the power indicator, by draw the operation knob at first and pushing in
once again, when the power indicator is turning off.
Be sure to pull out the operating knob when performing manual operation.
The auto reset feature (optional) incorporated into the Motor Operator changes the position
in which the operating handle is when the breaker tripped, as shown in the following table.
Cause of trip
OFF
Manual trip operation in the
ON state
Trip operation by SHT / UVT
Overcurrent trip
The Motor Operator provides RESET operation to the breaker.
When the thermal-magnetic circuit breaker is tripped by the thermal overcurrent trip device,
wait for several minites before performing
ON operation.
Connector plug
E
ON
2.2×L9.5
Tapping Screw
- 2pcs.
Key optional
Mounting
For detailed mounting dimensions, refer to the catalogue.
ON /
OFF , RESET operation
Complete breaker installation and wiring before mounting the Motor Operator. Otherwise,
complete installation and wiring is not possible.
power indicator
operating
knob
Handle position in tripped state
OFF
Standard
with Automatic reset
TRIP
OFF
Align positions of handle catch at a position of a handle of breaker before mounting the Motor
Operator.
After mounting, verify the function of the Motor Operator.
Safety Notices
Be sure to read these Instructions and other associated documents accompanying the product
thoroughly to be familiarize yourself with the product handling, safety information, and all other
precautions before mounting, using, servicing, or inspecting the product. In these Instructions,
safety notices are divided into " Warning" and " Caution" according to the hazard level:
Warning : A warning notice with this symbol indicates that neglecting the suggested procedure
or practice could be fatal or result in serious personal injury.
Caution : A caution notice with this symbol indicates that neglecting the suggested procedure or
practice could result in moderate or slight personal injury and/or property damage.
Note that failing to observe caution notices could result in serious injury/damage in some situations.
Because safety notices contain important information, be sure to read and observe them.
Operation Precautions
Never touch live terminals. Doing so may result in electric shock.
Installation Precautions
Electrical work should only be undertaken by suitably qualified persons.
OFF
Prior to commencing any work on the product, open an upstream circuit breaker or
isolator to ensure that no voltage is applied to the product. Otherwise, electrical shock
may result.
Do not touch the handle catch on the back of the Motor Operator. Doing so may cause
personal injury.
Be sure to connect terminal E to ground. Otherwise, electric shock may result.
Do not take the Motor Operator to pieces. Doing so may cause personal injury.
Operation Precautions
When the breaker trips open automatically, remove the cause, then do (ON) operation.
Should a fault be interrupted, the breaker must be inspected. Otherwise, a fire may result.
Do not apply excessive force to the operating part. Otherwise, damage may occur.
Wiring 1
2
0.8-2mm
Control Switch rating
OFF
Power source capacity
(back view)
Supply voltage specification (Uc) is shown on the nameplate. Supply voltage type is as follows.
handle catch
100/110V AC
230/240V AC
48V DC
200/220V DC
Polarity symbols "+" and "–" apply to DC power supply.
Warning
Caution
(AWG18-14)
100V, 0.1A
TPMC16S
300VA
Uc
Supply voltage type
200/220V AC
24V DC
100/110V DC