shawmut Protex SR9520 User Instructions

Advertisement

User Instructions
SR9520/SR9520S/SR9525/SR9525S/SR9530/SR9530S
Models SR9520/SR9520S/SR9525/SR9525S/SR9530/SR9530S
IMPORTANT: Keep these User Instructions for reference.
Read User Instructions before use. Misuse of this product may result in sickness or death. For questions about use,
consult supervisor or reach out to Shawmut LLC at service@shawmutcorp.com or 1-800-448-3457, ext. 1252.
PLEASE READ: IMPORTANT Before use, wearer must fully read and understand these User Instructions. Keep
these instructions for reference.

Fitting Instructions

Follow these instructions each time N95 respirator is worn.
Fig 1.
Position the respirator in your hands with the nose piece at your fingertips. Cup the respirator in your hand
allowing the headbands to hang below your hand. Hold the respirator under your chin with the nosepiece up.
Fig 2.
The top strap goes over and rests at the top back of your head. The bottom strap is positioned around the neck
and below the ears. Do not crisscross straps.
Fig 3.
Place your fingertips from both hands at the top of the metal nose clip. Slide fingertips down both sides of the
metal strip to mold the nose area to the shape of your nose.
Additionally, check your seal each time N95 respirator is worn as follows:
Fig 4.
Place both hands over the respirator, take a quick breath in to check whether the respirator seals tightly to the
face. Place both hands completely over the respirator and exhale. If you feel leakage, there is not a proper seal.
Particulate Respirator N95

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Protex SR9520 and is the answer not in the manual?

Questions and answers

Summary of Contents for shawmut Protex SR9520

  • Page 1 Read User Instructions before use. Misuse of this product may result in sickness or death. For questions about use, consult supervisor or reach out to Shawmut LLC at service@shawmutcorp.com or 1-800-448-3457, ext. 1252. PLEASE READ: IMPORTANT Before use, wearer must fully read and understand these User Instructions. Keep these instructions for reference.
  • Page 2 If air leaks around the nose, readjust the nosepiece as described in Fig 3. If air leaks at the respirator edges, re- adjust the straps along the sides of your head until a proper seal is achieved. If you cannot achieve a proper seal due to air leakage, do not enter contaminated areas.
  • Page 3 -4 °F (-20 °C) to +86 °F (+30 °C). Use respirators before the “use by” date specified on this container. FOR MORE INFORMATION In North America, contact: Shawmut LLC, 208 Manley Street, West Bridgewater, MA 02379 Website: www.shawmutcorp.com/safety Technical Assistance: 1-800-448-3457, ext. 1252. ©2020 Shawmut LLC. All Rights Reserved.

This manual is also suitable for:

Protex sr9520sProtex sr9525Protex sr9525sProtex sr9530Protex sr9530s

Table of Contents