Haier GE NS16AS Service Manual page 5

Single stage split system air conditioner up to 16 seer
Hide thumbs Also See for GE NS16AS:
Table of Contents

Advertisement

REFRIGERATION DATA
Refrig. Charge
Model
(oz.) *
NS16A18SA4
73
NS16A24SA4
73
NS16A30SA4
88
NS16A36SA4
113
NS16A42SA4
140
NS16A48SA4
156
NS16A60SA4
192
*Factory charged for 15 feet of line set
** Field supplied adapter required
COOLING PERFORMANCE WITH DTC
Outdoor Model
NS16A18SA4
NS16A24SA4
NS16A30SA4
NS16A36SA4
NS16A42SA4
NS16A48SA4
NS16A60SA4
1 DTC = Designated Tested Combination
31-5000749 Rev. 0
Refrigerant Line Size
TXV
Suction
H4TXV01
3/4
H4TXV01
3/4
H4TXV01
3/4
H4TXV02
7/8
H4TXV02
7/8
H4TXV02
7/8
H4TXV03
1 1/8
1
Capacity
Indoor Model
(BTUH)
NCUC24B
18,000
NCUC24B
24,000
NCUC30B
28,400
NCUC36B
34,000
NCUC49C
40,000
NCUC60C
46,000
NCUC60C
58,000
Page 5
Outdoor Unit Connection Indoor Unit Connection
Liquid
Suction
Liquid
3/8
3/4
3/8
3/8
3/4
3/8
3/8
3/4
3/8
3/8
7/8
3/8
3/8
7/8
3/8
3/8
7/8
3/8
3/8
1-1/8
3/8
EER
SEER
12.20
14.00
12.20
14.25
12.20
14.00
12.20
14.25
12.20
14.00
12.20
14.00
11.70
14.00
Suction
Liquid
3/4
3/8
3/4
3/8
3/4
3/8
7/8
3/8
7/8
3/8
7/8
3/8
7/8**
3/8

Advertisement

Table of Contents
loading

Table of Contents