Download Print this page

V-Count Ultima Go Quick Installation Manual

Advertisement

Quick Links

Ultima Go Quick Installation Guide
What is included in the box:
Ultima AI Sensor
4 screws
Labels for cables
7 cm bracket
Important Notes!
1.
2.
Requirements
1.
A Laptop to connect and configure the sensor.
2. A POE Injector or an adaptor to power the sensor during configuration. (Not included in the box, you will
need to purchase it separately).
3.
A laser meter to measure the ceiling height.
4.
Ethernet cable to install between the switch/modem and the sensor location.
5.
Ethernet crimp tool and a cable tester to test the cable health.
6.
A ladder to climb the ceiling.
Credential request
1.
Upon receiving the sensor, please request your credentials for the sensor
immediately.
2.
Send an email to your authorized reseller.
3.
If you are a direct customer of V-Count, please email help@v-count.com with the
following format.
To: help@v-count.com
Subject: Sensor Credentials Request for (Company Name) (Serial No)
Content: Provide a contact e-mail and a phone number.
Serial No is on the back of the sensor or on the box under the name MAC ID. It's
a 12 digit hexadecimal number starting with OO:15: FD...
Only use 9V 3A adaptors
Use a UPS for
if you want to power the
uninterrupted power.
sensor with an adapter.
Frequent power cuts
3.
Any other equipment
may damage the
may damage the
sensor board.
sensor.
Installation Steps
Step 1 - Determine the sensor location (Do not mount the sensor yet)
V-Count people counting sensors are usually installed at the location entrances near the doors. Sensor
location should be selected carefully, or doors may block the sensor view and may decrease counting quality.
Here are 3 different types of scenarios you may have:
Sliding Door
There's no chance for
door(s) to block the
sensor view. You may
determine the position
60cm away from the
door (on the inside of
the building).
Door Opening Inside
There's a chance the
door(s) may block
the sensor view.
Open the door(s)
and measure 60cm
away from door
endings.
Step 2 – Ethernet & Power Cabling
V-Count sensors will need an internet connection to send counting statistics to V-Count
servers so that you can browse them through our analytics platform on the web. Please
install ethernet cables from the location switch to the sensor location.
If your switch is a POE switch, you will need a splitter on
the sensor side. You can split the data and power and
use it with the sensor. Please remember to send the
voltage to 9V.
Door Opening Outside
There's no chance for
doors to block the
sensor view. You may
determine the position
60 cm away from the
door (through inside of
the building)
Alignment
Sensor location should
be aligned centrally in
the entrance. For more
complex entrances,
please see the "Need
Support" section of this
document.
If your switch is not a POE switch, you should also
install power cables and power the sensor with an
adapter.

Advertisement

loading

Summary of Contents for V-Count Ultima Go

  • Page 1 Installation Steps Step 1 - Determine the sensor location (Do not mount the sensor yet) V-Count people counting sensors are usually installed at the location entrances near the doors. Sensor What is included in the box: location should be selected carefully, or doors may block the sensor view and may decrease counting quality.
  • Page 2 Step 6 - Request Sensor Activation After you see the cloud online sign, send an e-mail to V-Count reseller or V-Count to get your sensor activated. If you are a direct V-Count customer you may write to help@v-count.com to request the activation of your sensor. Please use the following format: To: help@v-count.com...