AG GFC400 Operating Instructions Manual

Gas countertop fryer

Advertisement

Quick Links

Gas Countertop Fryer
Operating Instructions
Before you begin, please read these instructions carefully to
use this product correctly, to make the product perform ideally, and
to avoid hazards.
Models: GFC400

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GFC400 and is the answer not in the manual?

Questions and answers

Summary of Contents for AG GFC400

  • Page 1 Gas Countertop Fryer Operating Instructions Before you begin, please read these instructions carefully to use this product correctly, to make the product perform ideally, and to avoid hazards. Models: GFC400...
  • Page 2 Dear customers and users: Thank you for purchasing our products. In order to be able to better use this product, please read these instructions carefully before any operation, and follow the guide, to avoid any unnecessary trouble during using. Please keep this instruction manual in a safe place for convenient reference and operation.
  • Page 3: Table Of Contents

    Gas Countertop Fryer The Installation, Operation and Maintenance Guide Contents 1. Safety Protection ........- 3 - 2. Brief Introduction ........- 3 - 3. Manufacturer's Authority and Responsibility ..... - 3 - 4. Parameter Specifications ........ - 4 - 5.
  • Page 4: Safety Protection

    1. Safety Protection Please make sure that the operator is an authorized and licensed technician before you allow him/her to install and operate the products. Be sure to strictly follow this instruction guide during installation and using. The manufacturer is not responsible for any danger or accidents caused by improper operation or maintenance.
  • Page 5: Parameter Specifications

    4. Parameter Specifications 4.1、Outline Dimensions(mm) 4.2:Size and package parameter information <Table 1> Overall Packing size Model dimensions L x W x H L x W x H AT65G4F-C 400*650*485 490*740*620 Gas Connection: NOTE: ALL GAS FITTING MUST ONLY BE CARRIED OUT BY AN AUTHORISED PERSON. The product do not require an electrical connection, as they function totally on the gas supply only.
  • Page 6 Gas Type required for the appliance is shown in the rating label. Check that this is correct for the gas supply the appliance is being installed for. The gas conversion procedure is detailed in this manual. Supply Pressure required for this appliance is shown in the ‘Gas supply requirements’ section of this manual.
  • Page 7: Transport And Storage

    5. Transport and Storage In the process of transportation, handle carefully and keep upright to prevent damage of the product packing. Wrapped equipment should not be in open air for a long time, and shall be placed in a well-ventilated and non-corrosive gases warehouse.
  • Page 8: Safety Notices And Precautions

    same level with other series of the same stove; Please lift the equipment rather than drag if you need to move it. Supplied gas pressure regulator is factory set at 1.0kPa for Natural Gas and 2.5kPa for L.P. Gas; The equipment can only be placed on the noncombustible floor,and keep a distance of at least 6 inches(152mm) to equipment’s both sides 、...
  • Page 9: Operating Instructions

    Warning! Operation instruction must be placed in a conspicuous location. When customers smell gas in the process of using, should take safety precautions immediately. Immediately turn off the main gas valve, extinguish all heat and flames. Safety information can be obtained from your local gas suppliers.
  • Page 10 1、Turn ignition control knob anticlockwise from “●” to near “ ”, as shown in Fig.1. 2、Then press ignition control knob to the bottom and keep pressing it about 10-15 seconds, then turn it anticlockwise till it rings and reaches“ ”. Release the knob and observe stability of fire, the pilot is ignited and the equipment is under standby mode.
  • Page 11 Do not ignite the main fire without any oil in hydro-cylinder to damage equipment, even cause severe accidents; 8.3、Turn off the fryer 1、Turn ignition control knob clockwise from “ ” to “ ”, as shown in Fig. 2. Then, the main burner is extinct, the pilot is igniting and the equipment is under standby mode.
  • Page 12: Cleaning And Maintenance

    prevent a fire caused by continuous rise of oil temperature. If the thermal circuit breaker is activated, follow these steps: ●Wait for about 15 minutes for the oil to cool down. ●Press the button on the thermal cut out. If the thermal cut out cannot be manually reset, Please wait a moment, it may be that the oil temperature has not dropped to a certain temperature, or call your service agent.
  • Page 13: 10.Service (Authorized Technicians Only)

    Strictly follow the lighting instructions to work again after cleaning! Warning: Wait for the equipment to cool down after the unit has been turned off before you cleaning! Cut off the gas source as not using; If the equipment is not used for a long time, clean the surface by wiping it with a soft cloth and place it in a well-ventilated area;...
  • Page 14: Troubleshooting

    11. Troubleshooting <Table 4> Possible causes Problem solving Problems 1.Insufficient 1.Contact the local pressure in pipe gas supply dept. Not lighting 2.Nozzle occlusion 2.Dredge nozzle 1.Insufficient 1.Contact the local pressure in pipe gas supply dept. 2.The main fire nozzle 2.Dredge nozzle occlusion 3.Gas control valves 3.Change...
  • Page 15 Notice: 1、Pressure maintaining valve connects with air intake, must be installed by authorized and licensed technicians, to ensure interface tightness. 2、When the regulator is connected, the maximum load value of natural gas can not exceed 1.13kPa, the maximum value of liquefied gas can not exceed 2.75kPa. 3、Screw the hex nut (Fig.5) before connect air intake, ensure gas mark (Fig.6) on the plastic core match with connected gas source, if not, then pull out the plastic core and change another head, insert it again.