Camplux JK-5320 Instructions For Installation And Use Manual

Camping stove

Advertisement

Quick Links

CAMPING STOVE
Instruction For Installation And Use
Model: JK-5320
IMPORTANT: Read these instructions for use carefully. Familiarize yourself with the appliance before
connecting it to its gas container. Keep these instructions for future reference.
(844) 538-7475
support@camplux.com
3330-A Marathon Ct Charleston, SC 29418
Visit Us: Camplux.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the JK-5320 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Camplux JK-5320

  • Page 1 CAMPING STOVE Instruction For Installation And Use Model: JK-5320 IMPORTANT: Read these instructions for use carefully. Familiarize yourself with the appliance before connecting it to its gas container. Keep these instructions for future reference. (844) 538-7475 support@camplux.com 3330-A Marathon Ct Charleston, SC 29418...
  • Page 2: For Your Safety

    ● During stove set-up, check all fittings for leaks appliance. using soapy water. Never use a flame. (844) 538-7475 support@camplux.com 3330-A Marathon Ct Charleston, SC 29418 Visit Us: Camplux.com...
  • Page 3 (CO). Do not use in unventilated or tip. Some yellow tips on flames are acceptable enclosed areas to avoid endangering your life. as long as no carbon or soot deposits appear. (844) 538-7475 support@camplux.com 3330-A Marathon Ct Charleston, SC 29418 Visit Us: Camplux.com...
  • Page 4: Parts List

    Part No. Description KGZ-5430 Regulator Assembly Technical Characteristics Fig. 1 Model No. : JK-5320 ● Close both burner valves firmly. (Fig. 2) Item No. : SG-208-CM Gas consumption: 7.38MJ/Hr x2 Max output: 7,000BTU/Hr x2 Injector: 0.013inch x2 Category: Pressure regulated propane Fuel: 16.4 oz disposable propane cylinders...
  • Page 5: Leak Check

    ● Adjust flame with burner valve knob. Fig. 6 ● Never operate stove with propane cylinder in an Fig. 8 inverted position. (Fig. 7) OFF/SMALL flame ON/MAX flame Fig. 7 Fig. 9 (844) 538-7475 support@camplux.com 3330-A Marathon Ct Charleston, SC 29418 Visit Us: Camplux.com...
  • Page 6: Abnormal Operation

    Try to load the cylinder again correctly Clogged burner holes Use a metal brush to clean it Bent or rusty electrode Clean electrode No gas Replace fuel cylinder (844) 538-7475 support@camplux.com 3330-A Marathon Ct Charleston, SC 29418 Visit Us: Camplux.com...
  • Page 7: Things You Should Know

    24. When the normal flame starts to getting weak and finally distinguishes, it means the gas in the gas cylinder is used up. You will have to use a new gas cylinder with gas. (844) 538-7475 support@camplux.com 3330-A Marathon Ct Charleston, SC 29418 Visit Us: Camplux.com...
  • Page 8 (844) 538-7475 support@camplux.com 3330-A Marathon Ct Charleston, SC 29418 Visit Us: Camplux.com...

Table of Contents