Hide thumbs Also See for BLEPHASTEAM:

Advertisement

Quick Links

Instructions for use |
EYELID WARMING DEVICE, MOIST HEAT TECHNOLOGY

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BLEPHASTEAM and is the answer not in the manual?

Questions and answers

Summary of Contents for Théa BLEPHASTEAM

  • Page 1 Instructions for use | EYELID WARMING DEVICE, MOIST HEAT TECHNOLOGY...
  • Page 2 EYELID WARMING DEVICE, MOIST HEAT TECHNOLOGY INSTRUCTIONS FOR USE Please read these instructions before use Version: 2.6 - Release date 02/23/2021...
  • Page 3: Table Of Contents

    3.2. AFTER USING YOUR BLEPHASTEAM ..........................10 ® 7.3.2. Cleaning the mask (PN: T2422M) ......................... 21 3.3. LONG TERM STORAGE OF YOUR BLEPHASTEAM (longer than 2 months) ............... 10 ® 7.3.3. Cleaning the water carrier or face seal (PN: T2422FSA or FSC) ................22 DEVICE DESCRIPTION AND EXAM ENVIRONMENT .......................
  • Page 4 BLEPHASTEAM ® TABLE 7: ELECTROMAGNETIC EMISSIONS ........................... 24 While using BLEPHASTEAM , Meibomian glands are unblocked, tear quality is improved enhancing ocular surface health and comfort, ® leading to clear vision. TABLE 8: ELECTROMAGNETIC IMMUNITY .............................
  • Page 5: General Information

    ® facilitates its clearance though the application of pressure on the eyelids or massage. As shown in a number of clinical studies assessing For users of contact lenses or glasses, always remove them before using BLEPHASTEAM ® this device (in patients with MGD and/or dry eye related to MGD), this results in improving gland function, tear fi lm thickness and stability...
  • Page 6 ® 3 beeps and with green light pulsing. If the BLEPHASTEAM is left waiting for more than 10 minutes, the device will switch off and all the steps of the ® process will need to be restarted. Once preheating is complete, remove the device from its Massage your eyelids, and then clean them with a compress such as BLEPHACLEAN ®...
  • Page 7: After Using Your Blephasteam

    189 x 29 mm • Water tray (PN: T2422WT) Base station 0.291 kg 147 x 54 mm • Power supply (PN: T2422PS) Total weight and size of the BLEPHASTEAM 0.542 kg 189 x 102 x 141 mm ® • Screwdriver (PN: T2422SD) Table 1: Weight and size of the main elements • Set of rechargeable batteries (PN: T2422BAT) •...
  • Page 8: Safety

    Disconnect the device from power supply Caution ISO 15223-1 Serial number before servicing/cleaning Note Important information for operation ISO 15223-1 Product reference Pre-heat step of the BLEPHASTEAM ® (2-3 mins) light will Orange light pulse orange and give a short intermittent beep Patient information web site Green Light ashing and 3 beeps...
  • Page 9: Electrical Safety

    Table 3: Symbols on this device or deterioration 5.1.3 Disclaimer • Do not allow terminal to come into contact with water as this may cause failure of the device. If BLEPHASTEAM ® is dirty, wipe it with a soft cloth containing no water The warranty is valid eighteen months from the manufacturing date.
  • Page 10: Blephasteam ® Description

    Head strap (PN: T2422HS) Applied Part base station BLEPHASTEAM ® (PN: T2422BS) Figure 6: Bottom view Figure 2: Front view 5.6.2 Interior side of BLEPHASTEAM ® Water tray (PN: T2422WT) Base station DC in Figure 3: Rear view WARNINGS Water tray This symbol indicates that the surface temperature is high. DO NOT TOUCH.
  • Page 11: Screwdriver

    10 minutes (corresponding to the treatment time) . ® The battery power allows the user to operate the BLEPHASTEAM green Low Battery LED (See fi gure in 5.1) on the BLEPHASTEAM mask will illuminate continuously prior to the external batteries ®...
  • Page 12 CAUTION • Do not allow BLEPHASTEAM ® to come into contact with water as this may cause failure of the device. If BLEPHASTEAM ® (interior) is dirty, wipe a soft cloth containing no water Remove and store the batteries if the main unit will not be used for extended periods. Failure to do so may result in dead batteries.
  • Page 13 The spare batteries (PN: T2422BAT) and water carrier (PN: T2422FSA or FSC) must be ordered from Order new batteries (PN: T2422BAT) from green batteries light fl ashing. Laboratoires THÉA or from www.blephasteam.com. Batteries are becoming tired stockist. Replace batteries when convenient. (Should this occur, it will normally be * Batteries life and values mentioned above might vary depending on usage mode, connectivity and settings.
  • Page 14 RF compliance ® Flicker emissions acc. to IEC 61000-3-3 level above, additional measures may be necessary, such as reorientation or relocating the BLEPHASTEAM . In case ® unusual performance is witnessed, additional measures may be required such as change of orientation or location of the BLEPHASTEAM ®...
  • Page 15 Guidance and manufacturer declaration - electromagnetic immunity Recommended separation distances between portable and mobile RF communications equipment and the BLEPHASTEAM ® The BLEPHASTEAM is intended for use in the electromagnetic environment speci ed below. ® The BLEPHASTEAM is intended for use in an electromagnetic environment in which the radiated RF disturbances are ®...
  • Page 16 10. CONTACT If you have technical problems with our product, please contact the BLEPHASTEAM service line. We require the following information in ® order to provide you with the necessary assistance: • Serial number of your BLEPHASTEAM ® unit Laboratoires THEA France www.laboratoires-thea.com...

Table of Contents