Dimensions, weights, performance
Figure 6 and Table 3 contain data on the important dimen-
sions of the RP Ex fans.
Figure 6 – dimensional drawing of RP Ex fans
Table 4 - RP Ex fan basic parameters and nominal values
V
max
Fan type
m
3
RP EX – SINgLE-PHASE MOTORS
RP 40-20/20-4D Ex
1306
RP 50-25/22-4D Ex
1813
RP 60-30/28-4D Ex
3195
RP 60-35/31-4D Ex
3950
RP 70-40/35-6D Ex
4108
RP 80-50/40-6D Ex
5829
V
– maximum air flow at minimum permitted pressure loss
max.
∆p
– the maximum total fan pressure is the maximum of the sum ∆p
t max.
∆p
– the minimum allowed static pressure (pressure loss of the connected pipeline) indicates the lowest value at which the fan must be set
s min.
choked (at nominal voltage at point 5c) to prevent overloading and protection activation
n
– fan speed measured at the operating point with the highest efficiency (5b), rounded to tens
U
– nominal supply voltage of the motor without regulation (all values in the table refer to this voltage)
P
– maximum power of the electric motor at the highest load, i.e. at flow rate V
max.
I
– maximum phase current at voltage U and the highest permitted load, i.e. at flow rate V
max.
(after connection, it is necessary to check this value and mark the measured current in the warranty card)
t
– the highest permitted temperature of the transported air during flow V
max.
controller
– prescribed voltage regulator for fan regulation
m*
– fan weight (±10%)
6
∆p
∆p
t max
s min
/h
Pa
W
260
0
320
60
480
0
603
220
360
150
496
238
Table 3 – RP Ex Fan Dimensions
Fan type
RP 40-20/20-4D Ex
RP 50-25/22-4D Ex
RP 60-30/28-4D Ex
RP 60-35/31-4D Ex
RP 70-40/35-6D Ex
RP 80-50/40-6D Ex
n
U
P
nom
nom
max
min
V
W
-1
1400
400
281
1430
400
545
1440
400
1300
1440
400
2044
900
400
1100
930
400
1950
and ∆p
+ ∆p
(∆p
)
s
d
s
d
max.
max.
max.
Dimensions in mm
A
B
C
D
E
400
200
420
220
440
500
250
520
270
540
600
300
620
320
640
600
350
620
370
640
390
700
400
720
420
740
800
500
820
520
840
I
t
Control.
max
max
A
°C
type
0,5
40
TRN 2
0,93
40
TRN 2
2,32
40
TRN 4
3,9
40
TRN 4
2
40
TRN 2
3,7
40
TRN 4
in point 5c
max.
F
G
H
240
277
500
290
349
530
340
399
642
427
720
440
477
780
540
577
885
m
kg
13
18
33
47
44
68

Advertisement