Fixing Template for: 9943N5&N6, 9944N5&N6, 
9945N5L&R, 9945N6L&R, 9946N5L&R, 9946N6L&R
(suffix 'F' included to above denotes radiused forend)
FT9943N
Issue 01‐08/20
Reversing the latchbolt
Trigger
 32 
Recess for 
radiused forends
T: 020 7387 9951                                                                                                                                                                                                                      1                                                                                                                                                                                                                         www.allgood.co.uk
IMPORTANT NOTES:
To ensure lock functions correctly and that the warranty conditions are met:
The lock must be supported at the back of the case, the spindle must be 
                square to the face of door and installed in accordance with the fitting instructions.
Bolts should be checked frequently for easy action, and if required, lubricated 
                with light oil.
Some lock functions require certain holes to be cut one side only, check before cutting.
 22 
 19 
 28 
 4 
 72 
 20 
A
PILOT HOLES ONLY
FOR No.6 SCREWS
 
 105 
 114 
Door Gap:
 maintain nominal 3mm gap
                   between door and frame
Wiring diagram WD9943N
 19 
supplied with the lock
 2 
38 CRS
17 
 16 
 10 
Suitable for timber fire doors 30, 60 Min. and 
metal fire doors upto 240 Min. 
Timber door installation:
2812 ‐ CPR ‐ ABB035
When installing this product to an EN 1634 
3
EN 179:2008
compliant timber fire door, intumescent pack ref: 
9945N5L&R, 9945N6L&R, 9946N5L&R, 9946N6L&R
XX9943NFP for 30 & 60 Min. rating must be used.
(suffix 'F' included to above denotes radiused forend)
(see over page for instructions)
Important
Before fitting the lock, carefully read the instructions below:
Instructions:
1.
Before cutting the door, check whether lever & cylinder holes are required 
              on one or both sides of the door.
2.          Reversing the latchbolt
a.   Remove the retaining screw 'A' from the latchbolt assembly.
b.   Pull the latchbolt free.
c.   Turn the latchbolt around and twist it back into place in the lockcase, 
                    ensuring that the trigger is hooked behind the forend. (see drg. top left)
d.   Replace retaining screw 'A' ensuring it is fully tightenerd.
3.          When using half set of lever, use XX9052NT spindle (supplied C/W Fix. Inst.)
4.          Lever rose Assy. must be fitted back to back together using screws provided.
Note: Screws supplied with Lever Furn. should be fitted through the vertical slots of
the lock case, and additionally No. 6 self tapping screws supplied with lock case fitted 
horizontal. (see Fig. A overleaf)
Dimensions shown are guidance only, and for preperation of door, 
refer to actual lockcase to make allowances for cutting tolerances .
MAKE ALLOWANCES FOR WHEN FIRE PACK USED.      
 25* 
 32 
* MORTAR GUARD
    DIMENSIONS
Allgood plc, 63‐83 Brearley Street
Birmingham B19 3NT
15
7
6
B
1
3
4
2
A
B/D
CF 623
 3.0 
 17 
MORTAR
GUARD
 27 
Recycle responsibly

Advertisement

loading
Need help?

Need help?

Do you have a question about the 9943N5 and is the answer not in the manual?

Questions and answers

Summary of Contents for allgood 9943N5

  • Page 1 IMPORTANT NOTES: Suitable for timber fire doors 30, 60 Min. and  Fixing Template for: 9943N5&N6, 9944N5&N6,  Allgood plc, 63‐83 Brearley Street To ensure lock functions correctly and that the warranty conditions are met: metal fire doors upto 240 Min.  Birmingham B19 3NT • The lock must be supported at the back of the case, the spindle must be  Timber door installation: 9945N5L&R, 9945N6L&R, 9946N5L&R, 9946N6L&R 2812 ‐ CPR ‐ ABB035                 square to the face of door and installed in accordance with the fitting instructions. When installing this product to an EN 1634  EN 179:2008 (suffix 'F' included to above denotes radiused forend) • Bolts should be checked frequently for easy action, and if required, lubricated  compliant timber fire door, intumescent pack ref:  9945N5L&R, 9945N6L&R, 9946N5L&R, 9946N6L&R                 with light oil. XX9943NFP for 30 & 60 Min. rating must be used. FT9943N (suffix 'F' included to above denotes radiused forend) Issue 01‐08/20 • Some lock functions require certain holes to be cut one side only, check before cutting. (see over page for instructions) CF 623  22   19  Reversing the latchbolt Door Gap:  maintain nominal 3mm gap Important                    between door and frame Before fitting the lock, carefully read the instructions below: Instructions: Wiring diagram WD9943N Before cutting the door, check whether lever & cylinder holes are required ...
  • Page 2 Fixing Template for: 9943N5&N6, 9944N5&N6,  9945N5L&R, 9945N6L&R, 9946N5L&R, 9946N6L&R (suffix 'F' included to above denotes radiused forend) FT9943N Issue 01‐08/20 Dimensions shown are guidance only, and for preperation of door,  Q =  8 Through holes for Quadaxial Furn. FRAME PREP DETAILS refer to actual lockcase to make allowances for cutting tolerances.    * =  25 Bore ‐ use drilling jig provided   32   30           with Quadaxial lever furniture. *WITHOUT  27*   28  DOOR PREP DETAILS  =   Pilot holes for No. 6 self tapping screws   FIREPACK  5   26*   6   25   3*  *WITHOUT  19*   4*    FIREPACK  31  DOOR  38 CRS  FRAME   18  SQUARE FOREND FRAME FRAME MATING RECESS SHOWN SECTION PLAN VIEW...

This manual is also suitable for:

9943n69944n5944n69945n5l9945n5r9945n6l ... Show all