Page 1
OPERATION MANUAL TYPE: AP3001 Please read this manual carefully, and follow this manual strictly. Please keep it properly after reading for future reference...
operation manual 1 Security note 2 Product Introduction Control panel Other items in the package 3 Before use Record the beginning use date in the label Learning air quality indicator Method of dismounting and installation Placement sites of Air Purifier Install filters Filters and functions 4 How to use...
operation manual 1 Security Note In order to avoid possible damage to you or others or financial damages, please be sure to pay attention to the following safety precautions. If the machine's power supply cord is damaged, you must entrust the manufacturers of the machine, maintenance service center or qualified technicians will change for you, in case of any danger.
Page 5
operation manual Attention Attention This appliance contains a UV-C emitter. Any situation as below , please turn off Do not stare at the light source. the power of the machine. Unintended use of the appliance or damage to the housing may result in the escape of dangerous UV-C radiation.
operation manual 2 Product Introduction Air outlet Handle Air quality indicator Air Quality Sensor Back cover Air inlet (two sides) Power cord hole UV tube Efficiency HEPA filter The front panel Photoresistance Activated carbon filter Pre-filter Photo-catalyst filter...
operation manual Control panel Restoration button Wind speed adjustment Function button Power button Model button Timing button Other items in packing Air quality indicator (PM2.5 = 0 ~ 50) Blue Perfect (PM2.5 = 50 ~ 100) Green Good (PM2.5 = 100 ~ 150) Purple Normal (PM2.5 = 150 ~ )
operation manual 3 Before Use Record the beginning use date in the label In order to replace the filter on time, before using air purifier, please keep the date recorded in the back of the nameplate, thus to achieve the best performance. Nameplate and notes Tips...
operation manual Method of dismounting and Placement sites of air purifier installing the front panel In order to make your room air to achieve good 1 Method of removing the front Panel. effect on both sides of the cycle, to ensure the Hold on to the groove at both sides of the front gap between the air inlet and the wall at least panel, then gently pull it up.
operation manual 2.Hold on the grooves at both sides of the front Install Filter panel, then gently pull it up. Information Please remove all the package of all the filters in the machine before using the air purifier, according to the below instruction. Attention Please make sure the power plugs have been put off before installation, maintenance and transportation.
Page 11
operation manual 5.Please pull out the transparent tape from 7.Install the front panel again. Align and insert UV lights. it to the fixed grooves, then gently push it. 6.Install the pre-filter as the instruction. Tips Please be carefully when install the front panel.
operation manual Filters and function One: Pre-filter Use micron mesh filter, effectively block 2.5mm fibrous particulate matter, Blocking rate > 99.9%. It can be cleaned easily by tens of thousands times. Preventing larger particles such as pet fur, dander and coarse dust, etc. Can increase the life of the following filters.
Page 13
operation manual Five: Anion The allergens Produce large amounts of negative ions, physical adsorption, eliminate odors, has a strong adsorption. Coarse dust Hair Harmful Particles Dander Six: UV light, effective sterilization Dust Pollen Pet fur Smoke Effectively kill a variety of common bacteria Dust mites Odor Chemical substances...
operation manual 4 How To Use Control panel Plug in the power Starting air purifier Press the power switch to enter into auto mode with the lights on. When the machine start, the air quality indicator light will be slow flashing on, it begins to detect the air quality after preheating for 30s.
operation manual Air quality indicator Silent mode (PM2.5 = 0 ~ 50) Blue Perfect (PM2.5 = 50 ~ 100) Green Good (PM2.5 = 100 ~ 150) Purple Normal (PM2.5 = 150 ~ ) Notice: Please press the restoration button, if you want to turn off the air quality indicator light.
operation manual Anion Air quality indicator Flip this button to open/close air quality indicator. (light and data both for Ultraviolet AP3001B Style) Reset Timing function Reset the machine by pressing the button for at least five seconds, (This function is only available after the replacement remind of filter).
operation manual 5 Cleaning and 1 .Using a soft brush to clean the inlet/outlet of air quality sensor. Maintenance Be sure to pull out plug before cleaning. Do not put the product into water or any other liquid. Do not use corrosive or flammable gas (e.g.
operation manual Clean the pre-filter Operation steps 1. Turn off the power to stop the air purifier. Information In order to achieve the best performance, clean and maintain the Pre-filter every two months (about 480 hours) from the beginning to use. Based on the average 8 hours a day, 7 days a week frequency, keep the machine working under the household environment.
Page 19
operation manual 4.Removed the protruding part of the gauze 7.Re-install the front plate, align and insert into filter before cleaning it. the fixed groove, then gently pushed it up. 5.Use a soft brush or a vacuum cleaner to 8.Plug in. remove particles, please use water or soap water to clean the filter, then place it into the machine when it is completely dry...
operation manual Replace filters Operation 1.Reminding to replace the filter. 2.Turn off the power, then pull out the A reminding of filter replacement comes power plug. when machine in normal working for more than 1600 hours, and the power lights flash slowly (the red lights flashing when standby, the blue lights flashing when it is working).
Page 21
operation manual 4.Take off all filters inside. 7.Re-install the front panel, keep alignment and inserted into the fixed groove, then gently push it up 5.Remove all the plastic package of the filters, put back into the purifier. 8.After replacing the filter, plug in power, hold on the reset button for 5 seconds, then machine resets.
operation manual Unused for a long time Replace filter reference time When the total machine work time reach to Pull out the power plug. (because the power 1600hours, the machine will notice to change consumption happened when it is standby.) the filter.
operation manual 6 Fault Handling This chapter list the possible problems when using this product. If you can't solve the problems based on the below information, please contact with our customer center or dealers. Condition Possible reasons Possible solutions To remove the front panel, then install the panel The front panel may not be installed.
operation manual 7 Additional recycling Place the product, please don't put together with the general life garbage. Please check the local regulations on classified collection of electronic and electrical products. Right place old product helps to avoid the potential negative effects on the environment and human health.
operation manual 8 Warranty Description According to the stipulations of the "new three guarantees", the machine warranty period is one year (from the date of invoice) (warranty range only used for family). 1. During the warranty period. All that is the quality of the product itself caused by fault, please service with complete product warranty certificate and upgrade free maintenance order of invoice in my company branch.
operation manual 9 Warranty Card Product name/item No. Fuselage number Purchase Date Shop name Phone number Dealer stamp Name Address Mobile Phone Zip Code Maintenance record...