  • Page 1 PurePlace Building Pro USER MANUAL...
  • Page 2 OCTO PurePlace uses the advanced AFLPCO®* Photocatalytic Oxidation method to sanitise surfaces and clean the air. Both effective and harmless, OCTO PurePlace is derived from enhanced aerospace technology (NASA patent released on public domain) and can eliminate viruses, bacteria, fun- gi as well as odours and volatile organic compounds.
  • Page 3 PUREPLACE BUILDING PRO USER MANUAL Thank You For Choosing OCTO PurePlace Building PRO Congratulations, you own the most advanced photocatalytic air purification sy- stem available! Before operating the AFL system please read this manual in its entirety. Doing so will give you important information to keep you safe from harm and ensure you get the most benefit from your AFL air purification system.
  • Page 4: Table Of Contents

    PUREPLACE BUILDING PRO USER MANUAL Table of Contents Important safety instructions ..............Features and Benefits ..................Technology ........................Controls and Status Panel ................Air Inlet and Outlet ....................Power Adapter ......................Outer Housing ......................Base Plate ........................Green AFLPCO™ Cell Access Panel ..........
  • Page 5: Important Safety Instructions

    PUREPLACE BUILDING PRO USER MANUAL For your safety and to ensure proper use carefully read the entire contents of this manual before operating the AFL unit. IMPORTANT SAFETY INSTRUCTIONS When operating any electrical appliance basic, precautions should always be followed for safety.
  • Page 6 PUREPLACE BUILDING PRO USER MANUAL Store and transport -20˚ C ~ 80˚ C, humidity 10% ~ 90% (Non Con- densing). Do not operate unit in ambient temperatures above 40˚ C. KEEP OUT OF REACH OF CHILDREN Only use the power adapters included with the AFL purification sy- stem.
  • Page 7 PUREPLACE BUILDING PRO USER MANUAL...
  • Page 8 PUREPLACE BUILDING PRO USER MANUAL...
  • Page 9: Features And Benefits

    Features and Benefits EASY OPERATION OCTO PurePlace Building Pro gives you the option of both a high or low setting, placing you in control of yourunique situation. The unit is designed to operate continuously and should remain in operation 24 hours a day, 7 days a week for best results.
  • Page 10 MADE IN USA QUALITY OCTO PurePlace Building Pro is made in America with quality American engineered parts. From durable light weight anodized aluminum plates down to the small stainless steel washable dust guards, every part of the OCTO PurePlace Building Pro is made with pristine quality and assembled by hand in the USA.
  • Page 11: Technology

    VOCs, ethylene and odors, but also sanitize surfaces. The OCTO PurePlace Building Pro utilizes our proprietary catalyst superior to any catalyst currently on the market. It contains nine rare catalyst metals and nano size particles to increase the kinetic rate of reaction creating millions of redundant oxidizers.
  • Page 12: Controls And Status Panel

    Controls and Status Panel The OCTO PurePlace Building Pro unit is controlled via the HIGH/LOW rocker switch located on the bottom panel, as illustrated below. Depending on contamination levels and area of coverage the switch should be rocked to either the HIGH or LOW setting and remain on 24 hours a day 7 days a week.
  • Page 13 PUREPLACE BUILDING PRO USER MANUAL The Status Panel is located on the front of your OCTO PurePlace Building Pro. The indicator lights on this panel will pro-vide you with important in- formation about the operating status of your unit. Each ballast and UVC lamp utilize a separate set of indicator lights to give you detailed status in- formation and ensure individual components are working properly.
  • Page 14: Air Inlet And Outlet

    Power Adapter The OCTO PurePlace Building Pro is powered using a 24 VDC power adap- ter with a rated input voltage of 100 - 240 VAC and 6 foot supply cord. The adapter connects to a 110 or 230 VAC 3 amp power cord that is 5 feet in length.
  • Page 15: Outer Housing

    Placement and Installation PLACEMENT SUGGESTIONS The OCTO PurePlace Building Pro is designed to be wall mounted. In cer- tain applications , it may be desirable to mount the unit to a ceiling . We recommend consulting an engineer or certified/ licensed contractor to determine the suitability of the desired mounting surface to sustain the weight of the OCTO PurePlace Building Pro securely and safely.
  • Page 16 Air Inlet or Air Outlet. The following are general placement guidelines: • Clearance - To ensure efficient use of your OCTO PurePlace Building Pro the unit should be placed at least 2 feet from any obstructions. •...
  • Page 17 Pro weighs 12 lbs. AFL and its affiliates are not responsible for any damage to the unit or injury to yourself or others if you elect to install the OCTO PurePlace Buil- ding Pro without utilizing qualified technicians. Use the suggestions on page 15 to determine the optimal mounting loca-...
  • Page 18 PUREPLACE BUILDING PRO USER MANUAL VERTICAL MOUNTING 1. Locate the (A) #10 pan head wood screws and (B) screw plug included with the products. 2. Using a Phillips head screw driver, drive the first screw into a wall stud for secure mounting, lea- ving the screw head approximately 1/8”...
  • Page 19 PUREPLACE BUILDING PRO USER MANUAL 6.Locate the (C) #10 flat head wood screws and drive them into the two mounting holes under the Gre- en AFLPCO™ Cell. The included screw plugs may be needed in hol- low walls to secure the unit effecti- vely in the absence of a stud.
  • Page 20 MOUNTING SLOTS from the wall. This screw will slide into the center mounting slot on your OCTO PurePlace Building Pro in step 4. The included screw plug may be needed in hollow walls to secure the unit effectively in the ab- sence of a stud.
  • Page 21: Initial Start Up

    24 hours a day, 7 days a week. To start up the unit, press the switch to the HIGH or LOW position. The OCTO PurePlace Buil- ding Pro will start, with the green lights, blue lights and OCTO PurePlace...
  • Page 22: Maintenance

    PUREPLACE BUILDING PRO USER MANUAL Maintenance The OCTO PurePlace Building Pro was engineered to be virtually mainte- nance free. The Dust Guards and AFL Plasma Ionisers should be cleaned of any debris periodically and the Green AFLPCO™ Cell should be replaced every two years.
  • Page 23 PUREPLACE BUILDING PRO USER MANUAL the unit. The Dust Guard should be cleared of any debris every six months or sooner in areas with higher particulate levels. Maintai- ning the Dust Guard is simple. The Dust Guard is held in place with magnets requiring no tools to remove it.
  • Page 24 Cell will decrease the effectiveness of the unit. After two years of use the blue Lamp Replacement light will begin to blink as a reminder that it’s time to replace the Green AFLPCO™ Cell. The OCTO PurePlace Building Pro utilises proprietary UVC lamps that can only be purchased from and authorized AFL dealer.
  • Page 25 While grasping the removal tab, located at the front of the Green AFLPCO™ Cell, push the retaining clip to release the Green AFL- PCO™ Cell. Then pull up on the Cell to remove it from the OCTO PurePlace Building Pro.
  • Page 26 PUREPLACE BUILDING PRO USER MANUAL Insert the new Green AFLPCO™ Cell by inserting the lamp pins into the four pin connectors first and then lower the back of the Green AFLPCO™ Cell until you hear the retaining clip activate FOUR PIN CONNECTORS Use a small flat head screw driver or other flat object to depress the Lamp Reset switches for 3 seconds each.
  • Page 27 PUREPLACE BUILDING PRO USER MANUAL Reverse the directions for removing the Green AFLPCO™ Cell Ac- cess Panel to return it to the original position and fasten securely using the four Torx screws. Be careful not to overtighten the screws to prevent them from stripping.
  • Page 28: Standard Warranty Declaration

    PUREPLACE BUILDING PRO USER MANUAL Standard Warranty Declaration New equipment, components and spare parts supplied by Air For Life UK Limited (“Air For Life”) are warranted to be free from defects in materials and workmanship at the time of delivery and to conform to the Company’s written specifications for a period of 2 (“Two”) Years from date of delivery...
  • Page 29 PUREPLACE BUILDING PRO USER MANUAL ce equipment, parts or components or effect such repairs as recommended by the manufacturer or by Air For Life. 4) Air For Life’s liability, with respect to equipment, components or parts proved, to Air For Life’s satisfaction, to be defective within the warranty period, shall be...
  • Page 30: Trouble Shooting Guide

    Check to make sure the power adapter is Building Pro won’t turn on? firmly plugged into the wall outlet and The indicator lights and OCTO the OCTO PurePlace Building Pro. PurePlace Building Pro letters are not illuminated and there is no air flow.
  • Page 31: Product Specifications

    Blowers 30 CFM Environmental Protection The OCTO PurePlace Building Pro Wall Mount, according to Directive 2012/19/EU, is subject to selective waste collection & cannot be thrown away with other household waste after the period of use. The user is obli- ged to transfer it to an entity that collects electrical waste &...