1
VB40a 40amp Voltage Booster Installation Guide
4-VB40aX1 and 4-VB40aX2
Single and Dual Fuel Pump Voltage Booster
Installation Guide

Advertisement

loading

Summary of Contents for DeatschWerks 4-VB40aX1

  • Page 1 DeatschWerks VB40a 40amp Voltage Booster Installation Guide 4-VB40aX1 and 4-VB40aX2 Single and Dual Fuel Pump Voltage Booster Installation Guide...
  • Page 2: Included Parts

    DeatschWerks VB40a 40amp Voltage Booster Installation Guide Table of Contents Included Parts ……………………………………………………………………….. Page 2 Important Notes …………………..……………………………………………….. Page 3 Suggested Tools …………………….………………………………………………. Page 3 Booster Wiring …………..…………...……….…………….……………………… Page 4 Menu and Opperations ………………..……………………...……………….. Page 6 Included Parts: • DW VB40a Voltage Booster •...
  • Page 3: Please Read

    Brushless fuel pump controller. The factory manual should supersede any contradiction. Note: The Deatschwerks VB40a voltage booster is limited to 40amps. Increased flow results will stop when total pump(s) amperage hits 40amps.
  • Page 4 DeatschWerks VB40a 40amp Voltage Booster Installation Guide Wiring the Voltage Booster 1a – Follow the picture below for wiring your VB40aX1 single fuel pump booster. The Red wire should go to a switched 12v source that is key on power capable of handling 50amps. The Black wire should be grounded to the chassis or another suitable ground location.
  • Page 5 DeatschWerks VB40a 40amp Voltage Booster Installation Guide 1b – Follow the picture below for wiring your VB40aX2 Dual fuel pump booster. Each Red wire should go to a switched 12v source that is key on power capable of handling 25amps. The Black wire should be grounded to the chassis or another suitable ground location.
  • Page 6 Menu and Operations 3 – When powered on you will be greeted by a Deatschwerks splash screen. To access, navigate and change settings use the roller wheel on the top of the VB40a. To select items, click the roller wheel in.
  • Page 7 DeatschWerks VB40a 40amp Voltage Booster Installation Guide 4 – Click the roller wheel to access the menu. If there is a lock set you will be shown the lock screen, enter the lock code if you have it. The default lock code is “4849” if it is present on a new booster. This will move you to the Status menu, this shows the current settings and the current voltage being output by the VB40a.
  • Page 8 DeatschWerks VB40a 40amp Voltage Booster Installation Guide For additional technical support please contact us at: TechSupport@Deatschwerks.com or 405.233.3991...