1. Box content Included in the fi nal package with the DFI-150 are: • 1x DFI-150 water circulation pump (incl. 3,5m power cable) • 1x Inlet and outlet Fitting Ø63mm • 1x Quick Guide...
2. About the DFI-150 The Dura Flow inverter circulation pump, DFI-150 is a self-priming centrifugal pump for recirculation and filtration of the water in small and medium sized pools with prefilter integrated. The DFI-150 is part of the full DuraLink solution. Communication is done using power line communication.
3.2. DFI-150 overview 3.2.1 Spare parts list Diagram reference number Description Spare part number SP_DFI-001 Filter-basket 1, 2, 3 SP_DFI-002 The fi lter cover + sealing SP_DFI-003 Filter cover sealing SP_DFI-004 Mechanical sealing 63 mm fi tting (pipe fi tting + nut 5, 6, 7 SP_DFI-005 fi tting) with sealing...
3.3. Wiring diagram and terminal blocks See LINK Master manual for further details regarding the wiring diagram and terminal blocks for connecting the power cable.
4. Installation instructions 4.1. Warnings Before installation and use of the pump, the basic safety warnings need to be understood. Specific contents include the following warnings: 1. Be careful of electric shock. The pump can only be installed in combination with the LINK Master.
6. Special function description and application 6.1. Internal protection functions See addendum 8.1 for corresponding error codes. In case of error, the error code will be displayed on the LinkTouch or can also be retrieved in the DuraCloud application. 6.1.1. Overvoltage and undervoltage protection •...
6.1.5. Dry pumping protection (no water protection) • The dry pumping protection is controller by the LINK Master • This feature only works from and above 2100 RPMs...
7. Attention points 7.1. High-speed running at start-up Every time the pump will be activated, the motor will start running at high speed to remove the air in the pipe. This is controlled by the LINK Master. 7.2. Filter cleaning The filter basket must be cleaned on a regular basis to guarantee the waterflow and to avoid any damage of the pump due to a blocked filter.
8. Addendum 8.1 Error code Display Fault Name Failure Cause Description Code - Overloaded At this time: - Use of a special motor or a motor with a 1) Please check whether the motor and the driver match Overcurrent during power greater than the applicable power.
Page 14
Propulsion Systems bvba Dooren 72 1785 Merchtem, Belgium Tel +32 2 461 02 53 Fax +32 2 706 59 60 www.duratech.be info@propulsionsystems.be DURAFLOW We reserve the rights to change all or part of the contents of this document without prior notice...
Need help?
Do you have a question about the DURAFLOW DFI-150 and is the answer not in the manual?