1) Introduction
The GNExL2 and GNExL1 are second generation flameproof
loudspeakers which are certified to meet the requirements of
the ATEX directive 94/9/EC and the IECEx scheme. The
loudspeakers can be used in hazardous areas where
potentially flammable atmospheres may be present. There are
four versions of each loudspeaker, 8 ohm or 16 ohm and
70V/100V Line transformer. On 70V/100V line transformer
units there are four output tappings for each size of
loudspeaker. The GNExL2 unit produces output levels in the
117dB(A) range and the GNExL1 unit produces output levels
in the 112dB(A) range.
The loudspeakers are Group II, EPL (equipment protection
level) Gb. Dependant on unit type and ambient temperature
the equipment is certified 'Ex d IIC Gb' and as such may be
used in Zones 1 and 2 with flammable gases and vapours with
apparatus groups IIA, IIB & IIC and temperature Classifications
of T1, T2, T3 and T4 dependant on ambient temperature, see
marking codes in section 2.
The equipment is also certified 'Ex d IIB Gb' and as such may
be used in Zones 1 and 2 with flammable gases and vapours
with
apparatus
groups
Classifications of T1, T2, T3, T4, T5 and T6 dependant on
ambient temperature, see marking codes in section 2.
2)
Marking
All units have a rating label, which carries the following
important information:-
ExL2 or
Unit Type No.
GN
Impedance:
8 ohm or 16 ohm
70V Line or 100V Line
Codes: GNExL1
Ex d IIC T4 Gb for Ta –60°C to +50°C
Ex d IIC T3 Gb for Ta –60°C to +70°C
Ex d IIB T6 Gb for Ta –60°C to +50°C
Ex d IIB T5 Gb for Ta –60°C to +65°C
Ex d IIB T4 Gb for Ta –60°C to +70°C
Codes: GNExL2
Ex d IIC T4 Gb for Ta –60°C to +50°C
Ex d IIC T3 Gb for Ta –60°C to +65°C
Ex d IIB T6 Gb for Ta –60°C to +50°C
Ex d IIB T5 Gb for Ta –60°C to +65°C
SIRA 13ATEX1139X
Certificate No.
IECEx SIR 13.0029X
Epsilon x:
Equipment Group
and Category:
INSTRUCTION MANUAL (ATEX)
GNExL2 and GNExL1
IIA
&
IIB
and
temperature
ExL1
GN
II 2G
Flameproof Loudspeakers
SIRA 13ATEXXXXXXX
Certificate No.
CE Marking:
Notified Body No.
"Warnings"
DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE MAY BE
PRESENT
ELECTROSTATIC HAZARD - CLEAN ONLY WITH A DAMP CLOTH
IF TEMPERATURE EXCEEDS 70ºC
BRANCHING POINT USE SUITABLY RATED CABLE AND CABLE
GLANDS
Year of Construction /
Serial No.
3)
Type Approval Standards
The loudspeakers have an EC Type examination certificate
issued by SIRA and have been approved to the following
standards:-
EN60079-0:2012 IEC60079-0:2011 (Ed6)
EN60079-1:2007 IEC60079-1:2007 (Ed6)
4)
Installation Requirements
The loudspeakers must be installed in accordance with the
latest issues of the relevant parts of the EN60079 standards or
the equivalent IEC standards – Selection, Installation and
maintenance of electrical apparatus for use in potentially
explosive atmospheres (other than mining applications or
explosive processing and manufacture):-
EN60079-14:2008
IEC60079-14:2007 (Ed4)
EN60079-10-1:2009
IEC60079-10:2008 (Ed1)
The installation of the units must also be in accordance with
any local codes that may apply and should only be carried out
by a competent electrical engineer who has had the necessary
training.
5)
Zones, Gas Group, Category and Temperature
Classification
The GNExL2 and GNExL1 sounders have been certified Ex d
IIC T4 , T3 and Ex d IIB T6 , T5 ,T4 dependant on ambient
temperature for full marking see section 2. This means that the
units can be installed in locations with the following conditions:-
0518
AT ENTRY OR 80ºC AT
i.e. 13 / 1GL25000001
General Requirements
Flameproof Enclosure 'd'
Electrical Installations in Hazardous
Areas (other than mines)
Classification of Areas, Gas
Atmosphere

Advertisement

loading

Summary of Contents for E2S GNE L2 Series

  • Page 1 INSTRUCTION MANUAL (ATEX) GNExL2 and GNExL1 Flameproof Loudspeakers 1) Introduction SIRA 13ATEXXXXXXX Certificate No. The GNExL2 and GNExL1 are second generation flameproof CE Marking: loudspeakers which are certified to meet the requirements of 0518 Notified Body No. the ATEX directive 94/9/EC and the IECEx scheme. The loudspeakers can be used in hazardous areas where “Warnings”...
  • Page 2 Area Classification: Safety Warning (Electrostatic Hazard) Zone 1 Explosive gas air mixture likely to occur in The acoustic horn section is made of ABS Plastic, therefore to normal operation. avoid a possible ELECTROSTACTIC CHARGE the unit must Zone 2 Explosive gas air mixture not likely to occur, only be cleaned with a damp cloth.
  • Page 3 SAFETY WARNING: If temperature exceeds 70ºC at entry or 80ºC at branching point use suitably rated cable and cable The above table also shows the maximum AC signal voltages glands. at which the loudspeakers can be operated. If a high IP (Ingress Protection) rating is required then a The current levels taken by the each loudspeaker will depend suitable sealing washer must be fitted under the cable gland.
  • Page 4 GNExL2 and GNExL1 8 ohm and 16 ohm Loudspeakers Link - - + + Figure 5 GNExL2 and GNExL1 8 ohm and 16 ohm low impedance loudspeakers have dual input terminals on the pcb assembly for input and output wiring. A cable of up to 2.5mm² can be connected to each terminal.

This manual is also suitable for:

Gne l1 series