INSTALLATION/OPERATION
OPERATING INSTRUCTIONS
The Remote Keypad Unit (RKU) is a portable, hand
held accessory for use with the York Variable Speed
Oil Pump Drive (VSOP). When connected to a VSOP
Drive it provides the ability to view the different con-
trols within the VSOP Drive. Typically, the RKU will
be used to determine what condition is causing the VSOP
Drive to fault. The RKU is powered by a 9 volt alkaline
battery (supplied). Auto Power-Down and backlight con-
trol features conserve battery life by automatically turn-
ing the RKU off after a specified time period and by
allowing selected use of the display backlight.
The Remote Keypad Unit has the abil-
ity to program many different controls
within the VSOP Drive. DO NOT
change any of these controls, they are
programmed at the factory and do not
require any adjustment. Problems as-
sociated with modifying any of these
controls WILL NOT be covered by war-
ranty.
VARIABLE SPEED OIL PUMP DRIVE
REMOTE KEYPAD UNIT
Supersedes: Nothing
INITIAL INSPECTION
Upon receipt, unpack and carefully inspect for any dam-
age sustained in transit (depression in the enclosure,
damage to parts, missing parts). If damage is apparent,
the shipping agent should be notified. If there are parts
missing, consult the Baltimore Parts Center.
The Remote Keypad Unit option consists of the follow-
ing components:
QTY
1
1
1
Form 160.00-NO7 (599)
00102VIP
DESCRIPTION
Remote Keypad Unit
4-conductor modular interconnection cable
9-volt alkaline battery

Advertisement

loading

Summary of Contents for York WAEXRK01

  • Page 1 The Remote Keypad Unit (RKU) is a portable, hand Upon receipt, unpack and carefully inspect for any dam- held accessory for use with the York Variable Speed age sustained in transit (depression in the enclosure, Oil Pump Drive (VSOP). When connected to a VSOP damage to parts, missing parts).
  • Page 2: Specifications

    SPECIFICATIONS Part Number WAEXRK01 Applicable Variable Speed Oil Pump Drive on Mod D (and later) YK chillers Controls with software revision 12.1 or higher Communication 4-conductor telephone modular type (RJll) Cable (6 position, 4 contact standard extension cable) Max Communication Distance...
  • Page 3 Not compatible with these drives 1. Normal operation. 12.1 2. STATUS indicator on RKU remains on at all times. 1. Normal operation. 12.3 2. STATUS indicator on RKU remains on at all times. 1. Normal operation. 13.1 2. STATUS indicator operates normally. YORK INTERNATIONAL...
  • Page 4: Power On And Off

    1. Check for excessive overload. Heatsink Over Temperature 2. Locate the VSOP drive in a cooler location. Timed Overload Check for overload on the oil pump motor. DC Undervoltage Verify line voltage. For any other fault codes, contact the factory for assistance. YORK INTERNATIONAL...
  • Page 5: Fault Codes

    The backlight is on whenever the RKU is powered The backlight turns on whenever a key is pressed and turns off 1 minute after the last key is pressed. The backlight is always off Note: For maximum battery life select data code = 2. YORK INTERNATIONAL...
  • Page 6: Low Battery Power

    RKU automatically turned off. Proud Sponsor of the 2000 U.S. Olympic Team 36USC380 P .O. Box 1592, York, Pennsylvania USA 17405-1592 Subject to change without notice. Printed in USA Copyright © by York International Corporation 1999 ALL RIGHTS RESERVED Form 160.00-NO7 (599)