Download Print this page

Toro 132-4162 Installation Instructions page 3

Elevator pressure relief and console wire harness protection kit

Advertisement

Installing the Fittings and
Routing the Hydraulic Hoses
1. Remove the bolts securing the side panel of the
machine as shown in
2. Disconnect the hydraulic hose connected to the
90-degree fitting on the lower valve
1. Small-tee valve
3. Install the small-tee fitting and O-rings to the 90-degree
fitting and connect the hydraulic hose as shown in
Figure
6.
4. Torque the fitting to 36 to 44 N-m (27 to 33 ft-lbs).
5. Disconnect the hydraulic hose connected to the tee
fitting on the top of the 9 section valve block
Figure
5.
Figure 5
(Figure
6).
Figure 6
(Figure
1. Large-tee valve
6. Install the large-tee fitting and O-rings to the existing
tee valve and connect the hydraulic hose as shown in
Figure
7.
7. Torque the fitting to 50 to 63 N-m (37 to 47 ft-lbs).
8. Install the short hose from the small-tee fitting to the
valve and bracket assembly previously installed, as
shown in
Figure
1. Valve and bracket
assembly
9. Torque the fitting on the valve and bracket assembly to
20 to 25 N-m (15 to 19 ft-lbs).
10. Torque the fitting on the short hose to 46 to 56 N-m
(34 to 42 ft-lbs).
7).
3
Figure 7
8.
Figure 8
2. Short hose

Advertisement

loading