Table of Contents

Advertisement

Quick Links

LocControl100
General operating instructions
(customer-specific aspects are described in a separate document)
Document no. 10.0296.6600.02
Version N
Author: Gerhard Jordi
The contents of this manual are the intellectual property of Schweizer Electronic AG. No user rights to
patents or other property rights are granted to third parties through its acquisition. All rights remain with
Schweizer Electronic. Except with our express permission, this manual may not be copied or duplicated,
either completely or partially, and it may not be communicated or made accessible to third parties.
LocControl100
Page 1 of 28
General operating instructions
10.0296.6600.01 Version N

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LocControl100 and is the answer not in the manual?

Questions and answers

Summary of Contents for Schweizer LocControl100

  • Page 1 Version N Author: Gerhard Jordi The contents of this manual are the intellectual property of Schweizer Electronic AG. No user rights to patents or other property rights are granted to third parties through its acquisition. All rights remain with Schweizer Electronic. Except with our express permission, this manual may not be copied or duplicated, either completely or partially, and it may not be communicated or made accessible to third parties.
  • Page 2: Table Of Contents

    ERSION CONTROL INTRODUCTION ............................5 ............................ 5 ENERAL REMARKS ISED RSP-100 N : ..........................6 OTICE PICTOGRAMS ............................7 LOCCONTROL100 COMMISSIONING AND MAINTENANCE CONCEPT ..........8 ............................8 NTRODUCTION ’ : ..................... 8 OMMISSIONING ENGINEERS ACTIVITIES ’ : ......................8...
  • Page 3 ATA ACQUISITION 16.2 ........................22 PERATING DATA READOUT OPENING THE LOCCONTROL100 TRANSMITTER AND RECEIVER ..........22 MAINTENANCE OF THE LOCCONTROL100 SYSTEM ..............23 LOCCONTROL100 SAFETY TEST EVERY THREE YEARS .............. 23 SERIAL NUMBER MANAGEMENT AND TRACEABILITY ..............24 DISPOSAL ............................. 24 LIMITED MANUFACTURERS GUARANTEE ..................
  • Page 4: Document Information

    0 Document information Document objective This document describes the general operation of the LocControl100 radio remote control for railways and railway vehicles. This manual does not cover customer-specific aspects, which are covered in separate documents. Version control Status When Changes to the previous version Replaced PEK 16.03.2008...
  • Page 5: Introduction

    The illustrations in the user handbook are sample photographs. Customer-specific executions may appear different. The LocControl100 radio remote control for shunting locomotives, railway vehicles and similar vehicles has been developed according to both the latest technical knowledge and the latest version of European standard EN 50239.
  • Page 6: Ised Rsp-100 Notice

    L’exploitation est autorisée aux deux conditions suivantes : 1) l’appareil ne doit pas produire de brouillage; 2) l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.” LocControl100 Page 6 of 28 General operating instructions 10.0296.6600.01 Version N...
  • Page 7: Pictograms

    This advice draws attention to dangers in the fields of electrical engineering and electronics. Work on electrical and electronic assemblies and LocControl100 components should only be carried out by a fully-qualified electrical engineer having a training certificate from the Schweizer Electronic Group.
  • Page 8: Loccontrol100 Commissioning And Maintenance Concept

    I) and adhere to Schweizer Electronic’s standards and directives. Training of their project planners and assembly mechanics. Personnel competence Commissioning and maintenance work on LocControl100 system components should only be carried out by qualified and trained personnel. LocControl100...
  • Page 9: Qualification Overview

    “Maintenance II” training stage The service organization As the manufacturer of the LocControl100, Schweizer Electronic possesses the necessary prerequisites for supporting LocControl100 RS partners. A service organization is available for authorized partners and supports these in both technical and logistics areas.
  • Page 10: Device Description

    (locomotive computer) in the form of electrical signals. With the LocControl100, it is also possible to send return messages from the technical unit via the receiver to the transmitter. This is called bidirectional radio traffic.
  • Page 11: System Security

    All the requirements of EN 50239, in particular safety-relevant functions, have been fulfilled for all safety-relevant order issuance possibilities. The LocControl100 is suitable for uses of software security performance level 3 (EN 50128) and SIL3 (EN 50129). Addressing Every installation is assigned a unique built-in address. This address is allocated by Schweizer Electronic once worldwide.
  • Page 12 Execution with open RFID slot Addressing ensures the unique assignment of transmitter remote controls to receiver remote controls when operating several radio remote controls at the same frequency. LocControl100 Page 12 of 28 General operating instructions 10.0296.6600.01 Version N...
  • Page 13: Transmission Security On The Radio Channel

    Telegram security according to EN 60870-5-1 → Telegram transmission according to EN50159-2 → Software security performance level 3 according to EN 50128 and SIL 3 according to EN 50129 → Radio standard EN 300-113 LocControl100 Page 13 of 28 General operating instructions 10.0296.6600.01 Version N...
  • Page 14: Radio Module „Msy" Notifications

    19.01.2010 Belgium BIPT none 24.02.2010 France Agence Nationale des Fréquences ANFR/DTCS/RTTE/17601-10/LL 29.01.2010 LocControl100 RS notifications Overview-table for placing on the market of LocControl100 RS according to article 6(4) to the directive 1999/5/EG. Country Organisation Register-Number issued Austria Office broadcasting BMVIT-640.825/0817-III/BFT/2009 10.12.2009...
  • Page 15: Safety Information

    LocControl100 is a technically sophisticated product. Nevertheless, danger can arise from the product if it is operated or repaired by insufficiently trained persons, or if it is not used as intended. Schweizer Electronic therefore strongly urges you to familiarize yourself with the operating manual as well as the instructions provided with the product, and to adhere strictly with the provisions provided therein.
  • Page 16: Safety Information For Operation

    Do not stand under high masts or trees → Do not stand close to open water No work should be carried out using the LocControl100 in the centre of storms where there is severe danger of lightning. This means →...
  • Page 17: Transmitter

    10 Transmitter 10.1 Technical Data - Transmitter The general technical data and characteristics of the transmitter can be found in the attached LocControl100 data sheet. This data is subject to modification at any time. Project-specific parameters and transmitter characteristics can be found in the project documentation.
  • Page 18: Se Of Operators Own Carrying Harness

    Schweizer Electronic cannot give its approval. If the purchaser or the operator uses a carrying harness that has not been approved by the Schweizer Electronic Group in writing, then all claims under the guarantee as well as claims for compensation against the Schweizer Electronic Group lapse.
  • Page 19: Lithium-Ion Batteries

    Lithium-ion batteries should be appropriately disposed of according to applicable local guidelines. If the operator is not in a position to dispose of batteries in a proper manner, he must return them to Schweizer Electronic at his own cost. LocControl100 Page 19 of 28 General operating instructions 10.0296.6600.01 Version N...
  • Page 20: Receiver

    12 Receiver 12.1 Technical Data - Receiver The general technical data and characteristics of the receiver can be found in the attached LocControl100 data sheet. This data is subject to modification at any time. Project-specific parameters and receiver characteristics can be found in the project documentation.
  • Page 21: Malfunctions

    If a locomotive is working with a radio module in the toll-free ISM band, it is possible that radio traffic can occasionally be disturbed by other radio devices, such as crane operating equipment. LocControl100 Page 21 of 28 General operating instructions...
  • Page 22: Operating Data

    16 Operating data 16.1 Data acquisition The LocControl100 memorizes operating data both in the transmitter and in the receiver. Both the transmitter and the receiver have a memory space where 6000 actions can be memorized. This corresponds to approximately 24 hours of operating time.
  • Page 23: Maintenance Of The Loccontrol100 System

    Every hardware or software exchange, as well as all test reports, must be filed by the implementing office in such a way that it can be traced again at any time. If necessary, Schweizer Electronic must be given access to these documents.
  • Page 24: Serial Number Management And Traceability

    Serial number management allows complete component traceability. In case of a systematic malfunction or an accumulation of failures, Schweizer Electronic can target its search for faulty or vulnerable parts or software and remedy the malfunction.
  • Page 25: Limited Manufacturers Guarantee

    This manufacturer’s guarantee is only valid and enforceable in the country where the product was bought, and also assumes that the product from Schweizer Electronic was destined for sale in that country. If the customer bought the product in a member country of the European Union, Iceland, Norway or Switzerland and if it was originally destined for sale in one of them by Schweizer Electronic, this manufacturer’s...
  • Page 26: Guarantee Claims

    The repaired or replaced product will be returned to the customer within a reasonable time. Schweizer Electronic will assume the shipping costs for repaired or replaced products and, if possible, will choose the same method of transport as the customer used for returning the faulty product.
  • Page 27: Limitation Of Liability

    International Sale of Goods of 11 April 1980. The court of law at the recorded place of business of Schweizer Electronic in Reiden, Switzerland, is responsible. At its own discretion, Schweizer Electronic also reserves the right to appeal to the court of law at the customer’s place of business or domicile.
  • Page 28: Further User Information

    2dBi. Afin de respecter les exigences de la FCC/ISED concernant l’exposition aux fréquences radio, ce système doit être installé pour assurer une séparation d’au moins 30 cm du corps humain à tout instant pour les antennes 6dBi max et 15cm pour les antennes 2dBi max. LocControl100 Page 28 of 28 General operating instructions...