Steffes ThermElect Hydronic 9100 Series Technical Data Sheet

Steffes ThermElect Hydronic 9100 Series Technical Data Sheet

Advertisement

Quick Links

Technical Data Sheet
9100 ThermElect Hydronic
2-Year Limited Manufacturer's Warranty
Clearances and Dimensions
Placement
The minimum area required for the installation of the system is 100 square feet per unit. This area must remain free of
debris and room air should be maintained at less than 85
and system designer to provide appropriate ventilation to control temperature in area where unit is placed.
Steffes | 3050 Highway 22 North | Dickinson, North Dakota 58601-9413 | 701-483-5400
Models 9150 and 9180
51"
80KW
STORAGE
MODULE
9180 - 98"
9150 - 77"
1
40
"
16
34"
IMAGE #:
8" MINIMUM
CLEARANCE
12" MINIMUM
CLEARANCE
36" MINIMUM
CLEARANCE
1"
CLEARANCE
REQUIRED
Storage Module (53kW and 80kW)
Back = 8 inches
Bottom = 1 inch (from combustible material)
Right Side = 12 inches
Top = 8 inches (from combustible material)
Left Side & Front = 36 inches (for ease in servicing)
Adhere to clearances and provide appropriate
ventilation to maintain no greater than 85
temperature in area where unit is installed.
NOTE:
Some electrical codes may require a greater
front clearance depending on operating
voltages and other factors.
1201158
REV:
0
Fahrenheit / 29
o
8" MINIMUM
CLEARANCE
36" MINIMUM
CLEARANCE
Celsius. It is the responsibility of the installer
o
12" MINIMUM
CLEARANCE
36" MINIMUM
CLEARANCE
1201159
IMAGE #:
REV:
0
F air
o
Rev 3

Advertisement

loading
Need help?

Need help?

Do you have a question about the ThermElect Hydronic 9100 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Steffes ThermElect Hydronic 9100 Series

  • Page 1 Fahrenheit / 29 Celsius. It is the responsibility of the installer and system designer to provide appropriate ventilation to control temperature in area where unit is placed. Rev 3 Steffes | 3050 Highway 22 North | Dickinson, North Dakota 58601-9413 | 701-483-5400...
  • Page 2 1. On-Peak/Off-Peak Signal: ThermElect responds to external load control device (contact closure) and charges during off-peak periods. Auxiliary contact is provided on the ThermElect for controlling external loads. If using the Steffes Time Clock Module for peak control, the direct wiring shown here is not necessary.
  • Page 3 Heat Pump Application can be used for room temperature control with the ThermElect Hydronic system. If so, Steffes recommends using a digital thermostat. To initiate a heat call, the system needs a switch closure from R to H. This energizes the primary loop pump outputs.
  • Page 4 Supply via step-down transformer - field installation. Add approximately 500 lbs to arrive at shipping weight. Storage capacity is based on a maximum core temperature of 1,400 degrees Fahrenheit. Rev 3 Steffes | 3050 Highway 22 North | Dickinson, North Dakota 58601-9413 | 701-483-5400...

This manual is also suitable for:

Thermelect hydronic 9150Thermelect hydronic 9180