Summary of Contents for Steffes ThermElect Hydronic 9100 Series
Page 1
Fahrenheit / 29 Celsius. It is the responsibility of the installer and system designer to provide appropriate ventilation to control temperature in area where unit is placed. Rev 3 Steffes | 3050 Highway 22 North | Dickinson, North Dakota 58601-9413 | 701-483-5400...
Page 2
1. On-Peak/Off-Peak Signal: ThermElect responds to external load control device (contact closure) and charges during off-peak periods. Auxiliary contact is provided on the ThermElect for controlling external loads. If using the Steffes Time Clock Module for peak control, the direct wiring shown here is not necessary.
Page 3
Heat Pump Application can be used for room temperature control with the ThermElect Hydronic system. If so, Steffes recommends using a digital thermostat. To initiate a heat call, the system needs a switch closure from R to H. This energizes the primary loop pump outputs.
Page 4
Supply via step-down transformer - field installation. Add approximately 500 lbs to arrive at shipping weight. Storage capacity is based on a maximum core temperature of 1,400 degrees Fahrenheit. Rev 3 Steffes | 3050 Highway 22 North | Dickinson, North Dakota 58601-9413 | 701-483-5400...