Elettronica Progetti Multi-Pull EP095Mini Instructions For Installation And Use Manual

Elettronica Progetti Multi-Pull EP095Mini Instructions For Installation And Use Manual

Table of Contents

Advertisement

Doc.: EP095Mini-WiFi-E-rev1.doc
INSTRUCTIONS FOR INSTALLATION AND USE OF
1. GENERAL INFORMATION................................................... 2
2. COMPOSITION .................................................................. 2
4. OPERATION ...................................................................... 3
4.1 Selecting discipline ......................................................... 4
4.10 Zeros ............................................................................ 6
4.2 Connecting shooters ....................................................... 5
4.3 Starting a round (START) ................................................. 5
sequence.......................................................................... 5
4.5 Delay between shots....................................................... 5
4.6 Sensitivity ....................................................................... 5
4.7 End of a round ................................................................ 5
4.8 Reset .............................................................................. 5
4.9 Coin mode ...................................................................... 5
5. DISCIPLINES ...................................................................... 7
5.1 Test for Trap ................................................................... 7
5.10 Manual DTrap ............................................................... 8
5.11 DTrap 7 - 8 - 9 ............................................................... 8
5.12 Skeet 2013.................................................................... 8
5.13 Shoot Off Skeet (after Qualification) ............................. 9
5.16 Test for Skeet................................................................ 9
5.17 Custom Skeet (3 schemes).......................................... 10
5.18 Skeet Timer ................................................................ 10
5.19 Compak Fitasc (40 schemes) ....................................... 11
5.20 Compak 2014 (40 schemes) ........................................ 11
5.21 Custom Compak (10 schemes)..................................... 12
5.22 Test Compak ............................................................... 12
5.23 Multi Compak ............................................................. 12
5.24 Manual Sporting ......................................................... 13
5.25 Custom Sporting (10 schemes) .................................... 13
5.26 Remote WiFi ............................................................... 13
5.27 Helices . Elicio ............................................................. 13
5.4 Universal Trap ................................................................ 7
5.5 Down the Line ................................................................ 7
5.6 Double Trap 2013/30 ...................................................... 7
6. PROGRAM MODE ........................................................... 13
6.1 Number of Targets ........................................................ 15
6.10 Skeet Custom 1-2-3 ..................................................... 16
6.11 Name with ChipCard ................................................... 16
6.12 Automatic Shoot-Off ................................................... 16
6.13 New Password ............................................................ 16
E.P. Elettronica Progetti s.r.l.
Via Traspontina, 25
00040 Ariccia (Roma) - Italy
tel.: +39 069342181
fax: +39 069344987
www.elettronicaprogetti.com
Rev.: 1
Issue Date : 21-11-15
CONTROL UNIT EP095Mini WiFi
INDEX
Rev. 0 Issue Date: 01-09-14
6.14 Pause
select the time delay. ..................................................... 16
6.15 Clutter Adjustment..................................................... 17
6.16 Target Delete/Back .................................................... 17
6.17 Skeet Lamps Delay ..................................................... 17
6.18 Helices: coin correspondance ..................................... 17
6.19 ISSF TV Finals ............................................................. 17
6.2 Coin box mode ............................................................. 15
6.20 Preferred Disciplines .................................................. 17
6.21 Remote Change Discipline .......................................... 17
6.22 DTL: only trap 8 .......................................................... 17
6.23 DTL: single point......................................................... 17
6.24 Fitasc Preferred .......................................................... 18
6.25 Traps in Manual Sporting............................................ 18
6.26 WiFi ........................................................................... 18
6.27 Sound at the End Round ............................................. 18
6.28 Skeet Timer 0,2/3 sec. ................................................ 18
6.29 Trap WiFi ................................................................... 18
6.3 Coin Box Sequence ....................................................... 15
all open ......................................................................... 18
6.30 Time Out .................................................................... 18
6.31 Delay of shots ............................................................ 18
6.31 Sound at the No Bird .................................................. 19
6.32 Sound at the Pause .................................................... 19
6.33 Sound at the Start ...................................................... 19
6.34 Chip memo config. ..................................................... 19
6.35 Chip memo compak custom 1/10 ............................... 19
6.4 Coin Box Targets .......................................................... 15
6.5 Trap Pulse Duration...................................................... 15
6.6 Reaction Time .............................................................. 15
6.7 Scoreboard Targets ...................................................... 15
6.8 Automatic No-Bird ....................................................... 15
6.9 Sporting Custom from 1 to 10....................................... 15
7. CHIP CARD ..................................................................... 20
7.1 Master Card ................................................................. 20
7.2 To select shooters with Chip Cards ............................... 20
7.3 Report Card ................................................................. 20
8. INSTALLATION ............................................................... 21
8.1 Plug for Traps - J1 ......................................................... 21
8.3 Plug for external coin box - J3 ...................................... 23
8.4 Plug for scoreboard or monitor - J4 .............................. 23
8.5 Plug for referee box - J5 ............................................... 23
8.7 Jack for speaker - J8 ..................................................... 23
8.8 Lamps for Skeet ........................................................... 23
8.9 Junction Box mod. EP096I1 .......................................... 23
9. GUARANTEE AND ASSISTANCE ....................................... 24
Page no.
1 of 24

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Multi-Pull EP095Mini and is the answer not in the manual?

Questions and answers

Summary of Contents for Elettronica Progetti Multi-Pull EP095Mini

  • Page 1: Table Of Contents

    6.12 Automatic Shoot-Off ........... 16 8.9 Junction Box mod. EP096I1 .......... 23 6.13 New Password ............16 9. GUARANTEE AND ASSISTANCE ........24 E.P. Elettronica Progetti s.r.l. Via Traspontina, 25 00040 Ariccia (Roma) – Italy tel.: +39 069342181 fax: +39 069344987...
  • Page 2: General Information

    370 x 270 x 135 mm. Total weight: 3.3 Kg. Data interface: isolated RS485 For WiFi: frequency 868 Mhz max output: 27dBm E.P. Elettronica Progetti s.r.l. Via Traspontina, 25 00040 Ariccia (Roma) – Italy tel.: +39 069342181 fax: +39 069344987 www.elettronicaprogetti.com...
  • Page 3: Operation

    The following figures show the main console front panel and the referee’s remote control front panel. Front panel of main unit Front panel of referee control box Front panel of switch-box for zeros E.P. Elettronica Progetti s.r.l. Via Traspontina, 25 00040 Ariccia (Roma) – Italy tel.: +39 069342181 fax: +39 069344987 www.elettronicaprogetti.com...
  • Page 4: Selecting Discipline

    For Helices ZZ of Elicio Gonzales Helices-Elicio Discipline for Helices Heli5 Squad Discipline for Helices: squad rotation Heli5 Competition Discipline for Helices: Competition rotation E.P. Elettronica Progetti s.r.l. Via Traspontina, 25 00040 Ariccia (Roma) – Italy tel.: +39 069342181 fax: +39 069344987 www.elettronicaprogetti.com...
  • Page 5: Connecting Shooters

    8 sec. will starts, then it’s possible to repeat only two targets (one double or two singles), then the unit will automatically reset. For Chip Card operation, refer to paragraph #7 to know the operating procedures. E.P. Elettronica Progetti s.r.l. Via Traspontina, 25 00040 Ariccia (Roma) – Italy tel.: +39 069342181...
  • Page 6: Zeros

    1 or no. 2 to modify the miss to hit or the hit to miss. No sound will be produced for this operation put the unit in "Start" to continue the round E.P. Elettronica Progetti s.r.l. Via Traspontina, 25 00040 Ariccia (Roma) – Italy tel.: +39 069342181...
  • Page 7: Disciplines

    Starting on Station 1, they must shoot at regular doubles (Scheme C) until the tie(s) are broken; Before the shoot-off starts, the Referee must show one regular double (Scheme C) E.P. Elettronica Progetti s.r.l. Via Traspontina, 25 00040 Ariccia (Roma) – Italy tel.: +39 069342181...
  • Page 8: Manual Dtrap

    The stand lamps will indicate the active microphone in order to advice the shooter when is possibile to call the target. The outputs for trap machines used are: E.P. Elettronica Progetti s.r.l. Via Traspontina, 25 00040 Ariccia (Roma) – Italy tel.: +39 069342181...
  • Page 9: Shoot Off Skeet (After Qualification)

    5.16 Test for Skeet Is used in order to test the 2 traps (before competition or for maintenance). Press START button. E.P. Elettronica Progetti s.r.l. Via Traspontina, 25 00040 Ariccia (Roma) – Italy tel.: +39 069342181 fax: +39 069344987...
  • Page 10: Custom Skeet (3 Schemes)

    During “Coin Box Mode” a fixed maximum number of targets is available for every shooter, like other discipline operating in “coin box mode”. E.P. Elettronica Progetti s.r.l. Via Traspontina, 25 00040 Ariccia (Roma) – Italy tel.: +39 069342181...
  • Page 11: Compak Fitasc (40 Schemes)

    Press the Yellow button on the main consolle to book the shooter: the cost of a round will be detracted from the card and the display will show the residue on the card E.P. Elettronica Progetti s.r.l. Via Traspontina, 25 00040 Ariccia (Roma) – Italy tel.: +39 069342181...
  • Page 12: Custom Compak (10 Schemes)

    Select, if necessary, another scheme by using the the RED button of the referee box. Note that the possible available schemes are at maximum 8 and are those selectable during programming Remove the card E.P. Elettronica Progetti s.r.l. Via Traspontina, 25 00040 Ariccia (Roma) – Italy tel.: +39 069342181...
  • Page 13: Manual Sporting

    6 numbers (from 1 to 6) by using the six shooter’s push-buttons. The default  value of password is: 666666 E.P. Elettronica Progetti s.r.l. Via Traspontina, 25 00040 Ariccia (Roma) – Italy tel.: +39 069342181 fax: +39 069344987 www.elettronicaprogetti.com...
  • Page 14 Possibility to store/recovery the unit configuration with a chip card Chip memo compak custom 1/10 6.37 Possibility to store/recovery the custom compak schemes with a chip card E.P. Elettronica Progetti s.r.l. Via Traspontina, 25 00040 Ariccia (Roma) – Italy tel.: +39 069342181 fax: +39 069344987 www.elettronicaprogetti.com...
  • Page 15: Number Of Targets

    It’s possible to set 5 custom sequences that can be used in two mode: like “Sporting Sequences” or like “Compak Sequences”. That means rotation of shooters along the stands can follow the rule of sporting or the rule of compak. E.P. Elettronica Progetti s.r.l. Via Traspontina, 25 00040 Ariccia (Roma) –...
  • Page 16: Skeet Custom 1-2-3

    It’s possibile to adjust the delay between two consecutive targets between 1,0 and 8,0 sec. Press FORWARD or BACK buttons to set a fixed delay. Press START button to store and exit. E.P. Elettronica Progetti s.r.l. Via Traspontina, 25 00040 Ariccia (Roma) – Italy tel.: +39 069342181...
  • Page 17: Clutter Adjustment

    With 1 point, every hit means 1 point. With 3 points: hit with first shot means 3 points, hit with the second shot means 2 points, miss means 0 points. E.P. Elettronica Progetti s.r.l. Via Traspontina, 25 00040 Ariccia (Roma) – Italy tel.: +39 069342181...
  • Page 18: Fitasc Preferred

    After this time out the lamp will start to blink. A stand become ready after a time delay (between 2 sec and 8 sec) from the last shoot of the previous shooter. E.P. Elettronica Progetti s.r.l. Via Traspontina, 25 00040 Ariccia (Roma) –...
  • Page 19: Sound At The No Bird

    Then insert a valid chip card and press START. The display will show the results of the operation. E.P. Elettronica Progetti s.r.l. Via Traspontina, 25 00040 Ariccia (Roma) – Italy tel.: +39 069342181...
  • Page 20: Chip Card

    The Report Card is a chip card formatted like Report Card from the management software. Rememeber that memory inside the EP095MINI unit allows to store a maximum number of 64 rounds (25 or 50 targets). E.P. Elettronica Progetti s.r.l. Via Traspontina, 25 00040 Ariccia (Roma) – Italy tel.: +39 069342181...
  • Page 21: Installation

    21 of 24 INSTALLATION Plug for Traps - J1 The 8 trap machines must be connected to the unit like in the following picture: E.P. Elettronica Progetti s.r.l. Via Traspontina, 25 00040 Ariccia (Roma) – Italy tel.: +39 069342181 fax: +39 069344987...
  • Page 22: Plug For Stand Lamps And No-Bird Push-Button - J2

    NOTE: the lamps used must operate at 12Vdc and maximum current of 100 mA. It’s suggested to use LEDs lamps produced from EP (series EPL). E.P. Elettronica Progetti s.r.l. Via Traspontina, 25 00040 Ariccia (Roma) – Italy tel.: +39 069342181 fax: +39 069344987 www.elettronicaprogetti.com...
  • Page 23: Plug For External Coin Box - J3

    The new model of Junction box do not have any switch to commutate between trap/skeet/compak: the unit will manage that by using two additional commands (1 and 2). E.P. Elettronica Progetti s.r.l. Via Traspontina, 25 00040 Ariccia (Roma) – Italy tel.: +39 069342181...
  • Page 24: Guarantee And Assistance

    24 of 24 GUARANTEE AND ASSISTANCE Elettronica Progetti products are guaranted to the original purchaser for two years from the date of purchase as shown on a valid receipt issued by the seller. This guarantee does not affect the consumer’s rights under European Directive 99/44/CE regarding certain aspects of the sale and guarantee of consumer goods;...

Table of Contents