wheezo® is intended to detect and record abnormal breath sounds (continuous adventitious breath sounds/CABS) at the windpipe (trachea), reported as WheezeRate in adults and children (2 years and older).
A licensed health care professional's advice is required to understand the meaning and importance of the wheezo® readings.
wheezo® Breath Sensor
USB-A to USB-C charging cable
Quick Start Guide
Owner supplied smart device
Made for iPhone 6s and up running iOS 13 or later
Select Android devices
wheezo® is not intended for diagnostic use. wheezo® is intended to detect and record abnormal breath sounds (continuous adventitious breath sounds/CABS) at the windpipe (trachea), reported as WheezeRate in adults and children (2 years and older). A licensed health care professional's advice is required to understand the meaning and importance of the wheezo® readings.
wheezo® has been designed for use in a quiet environment e.g. home, school or office. It is not designed to be used in direct air currents (e.g. wind), source of heat or cold, direct sun rays or other source of light or energy, dust, sand or any other chemical substances or performance will be affected.
If the user is feeling breathless, or experiencing other symptoms, it is important to prioritise treatment over taking a wheeze rate. Do not delay treatment. Regardless of the wheeze rate, if the user has signs and symptoms such as chest tightness, shortness of breath, coughing or wheezing, they should always follow their healthcare professional's advice. Electromagnetic interference (EMI) can occur in the home health care environment as control over other equipment cannot be guaranteed. Interference from other equipment can be recognized by interruption during recording. If this occurs, one of the following error messages will appear on the application screen: Something went wrong. (Error code: 266) - Try again
Couldn't find my breath sensor. Make sure it is switched on and within range - Try again There is no essential performance for the wheezo® device for the purpose of wheeze recording. The basic safety of the device is not affected if the recording is interrupted. Continuous transmission of breath sounds and background sounds to the respiri™ app over Bluetooth demonstrates the immunity to sources of electromagnetic interference. This has been demonstrated by complying with the standard IEC 60601-1-2. Moving away from the source of interference will usually allow the device to operate normally. Sources of interference may include communication equipment, wireless communication devices, household appliances, and industrial equipment. Examples are radio frequency identification systems (RFID), FM radio, television, cellular network of mobile phones, security systems, and microwave ovens. Portable RF communications equipment (including peripherals such as antenna cables and external antennas) should be used no closer than 30 cm (12 inches) to any part of wheezo® including cables specified by the manufacturer. Otherwise, degradation of the performance of this equipment could result.
Once removed from its packaging, check that there is no visible damage on the wheezo® breath sensor. In the case of damage, do not use it and return it to the seller. Use only with iOS and select Android devices Use only an AC adaptor that complies with IEC 60950-1 or IEC 60601-1* for charging The USB-C port on the bottom of the breath sensor is only for charging of the internal battery To prevent entanglement and strangulation, do not place the USB charging cable provided in reach of children Use only in environments specified in this Owner's Manual Do not expose to liquids Do not tamper with the blue sensor diaphragm Do not expose the device to extreme temperatures – very hot or very cold, high humidity, dust or direct sunlight. wheezo® should be used in temperatures 0° – 40°C. Do not drop the device or treat it roughly in any way Never attempt to repair the device yourself. Opening of wheezo® invalidates all guarantee claims Degraded sensors and microphones can affect performance The normal function of the product may be disturbed by strong Electro-Magnetic Interference. If so, simply reset the product to resume normal operation by following the instruction manual. In case the function cannot resume, please use the product in a different location The distance between the wheezo® device and smartphone must not exceed 1.3 meters. In compliance with the European Directive on Waste Electrical and Electronic Equipment (WEEE) 2012/19/EU, do not dispose of this product as unsorted municipal waste. Follow local, state and national governing ordinances and recycling instructions reading disposal or recycling of the device *IEC 60950-1 is the reference standard for power supplies under Information Technology Equipment. IEC60601-1 is the international basic safety and essential performance standard for electrical medical equipment and medical electrical systems.
30-DAY RETURN POLICY
Manufactured for
Respiri Limited
9/432 St Kilda Road, Melbourne, VIC, 3004, Australia
Distributed by
Respiri USA Inc
850 New Burton Road, Suite 201, Dover, DE 19904
support@respiri.co
Respiri Limited reserves the right to make changes and improvements to this manual and the products it describes at any time, without notice or obligation.
Download the full wheezo® Owner's Manual via www.respiri.co
and wheezo® are registered trademarks of Respiri Limited
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Download Respiri wheezo WZO01 - WheezeRate Detector Quick Start Guide
Advertisement
Need help?
Do you have a question about the wheezo WheezeRate WZO01 and is the answer not in the manual?
Questions and answers