EASY INSTALL GUIDE : M4/SOL - SYS
1. Unpack & Open Up the Metron4
3. Mount the Metron 4
4. Connect the B attery
EASY INSTALL GUIDE : M4/ SOL - SYS
6. Navigate the Metron4
8. View Data
sales@powtechnology.co.uk
sales@powelectrics.co.uk
Tel: +44(0) 1827 310 666
Tel: +44(0) 1827 310 666
EASY INSTALL GUIDE: M4/SOL-SYS
Place unit on a flat surface.
To open, loosen the 2
nylon
screws
bottom corners of the
Metron4 and 4 screws
around battery.
Allen key and Pozi / Phillips
head screwdriver required.
Ideally a flat surface such as a
wall/ DIN railing/ Unistrut railing.
Avoid mounting inside metal
cabinets or underground (could
reduce signal).
There are pre-drilled holes for
easy mounting.
Ensure the highlighted switch is
positioned at Solar.
Remove the white plastic cover
from the battery terminals.
Use the loose black and red wires
and slide on to connect to the
battery terminals.
Maintain polarity:
to
(-).
to
Press any button to wake the Metron4. Press left to cycle channels for immediate
reading (config. dependent) or enter PIN (1234) and press right after 4
enter homepage.
Move down to Force Transmit and right to select. Watch the progress bar and
wait for the unit to transmit. Once complete, data can be viewed on
MetronView. The unit will countdown for 45 seconds, then enter Run Mode.
Screen will turn off.
For live channel readings, channels can be selected from the menu by pressing
right on Channels and Read Now.
Visit:
www.metronview.com
Login credentials will have
been sent by email.
2. Mount the Solar Panel
in
the
5. Connect the Sensor(s)
(+).
7. Programming
Units can be remotely programmed from MetronView. It is
possible to change how often units are taken & sent, alter
scaling and alarm thresholds for each input channel and much
Solar panel comes attached to a
mounting bracket. The panel must
face directly south and have a view of
at least 100° of unobstructed sky.
The panel should be tilted at an angle
10° to 15° plus the site's latitude from
the horizontal to achieve maximum
sun exposure (example overleaf).
The higher the cell, the better.
The inputs shown in the blue box
connect directly to the inputs in the
yellow box on the Metron4 above
Run the sensor cable(s) through the
lower unit's glands.
Unplug the green connector(s) and
wire in as required.
Plug the connector(s) back into the
correct input channel and tighten the
gland. Ensure cable is through the
gland.
Reattach all lids and take care to
tighten screws to ensure waterproof
IP67 rating is maintained.
th
digit to

Advertisement

loading

Summary of Contents for POW Metron4 M4/SOL-SYS

  • Page 1 EASY INSTALL GUIDE: M4/SOL-SYS EASY INSTALL GUIDE : M4/SOL - SYS 1. Unpack & Open Up the Metron4 2. Mount the Solar Panel Solar panel comes attached to a mounting bracket. The panel must Place unit on a flat surface. To open, loosen the 2 face directly south and have a view of at least 100°...