Pelton & Crane Solaris Use & Care Manual

Pelton & Crane Solaris Use & Care Manual

Sterilization center

Advertisement

Quick Links

Solaris
Sterilization Center
Use & Care Manual

Advertisement

Table of Contents
loading

Summary of Contents for Pelton & Crane Solaris

  • Page 1 Solaris Sterilization Center Use & Care Manual...
  • Page 2: Table Of Contents

    Table of ConTenTs OVERVIEW ..........................................3 gEnERal InfORmatIOn ......................................4 ImPORtant SafEtY InStRUCtIOnS ................................... 5 gEnERal CabInEt InfORmatIOn ..................................6 ElECtRICal SUPPlY (all StagIng aREaS) ..............................7 OPERatIOn ..........................................8 OPERatIOn - StagE 1......................................9 OPERatIOn - StagE 1 (COntInUEd) .................................. 10 OPERatIOn - StagE 2......................................11 OPERatIOn - StagE 3......................................
  • Page 3: Overview

    Solaris Sterilization Center The Solaris Sterilization Center is uniquely designed into four staging sections that allow the user to keep each process of sterilization separated. Each stage station is divided by a partition to reduce cross-contamination and to improve man- ageable flow between each station.
  • Page 4: General Information

    34488 WaRnIng: Only authorized service technicians should Technical Description attempt to service this equipment. Use of other than Model Designation: Solaris Sterilization Center authorized technicians will void the warranty. Power Supply: 120V~60Hz, 15A Service Circuit Description Voltage Current Freq.
  • Page 5: Important Safety Instructions

    IMPoRTanT safeTY InsTRUCTIons When using electrical furnishings, basic precautions should always be followed, including the following: Read all instructions before using the cabinet. Save these instructions. WaRnIng: Only authorized service technicians DangeR: To reduce risk of electrical shock: should attempt to service this equipment. Serviced 1.
  • Page 6: General Cabinet Information

    CabIneT InfoRMaTIon Thank you for purchasing your new Solaris Sterilization Center. It is engineered to provide many years of reliable performance. However, a certain amount of care is required. Conscientious adherence to the Use & Care Instructions will ensure that your unit will function to your satisfaction for many years to come.
  • Page 7: Electrical Supply (All Staging Areas)

    (Stage 3). 2. Electrical outlet is on Stage 3. This outlet must be hard- The Solaris is equipped with a constant power switch wired to accommodate 120V or 230V outlets. (P), located on the control panel above the sink cabinet.
  • Page 8: Operation

    oPeRaTIon 4. Air outlets are located in the sides of the power strips in stages 1 and 2. These outlets accept a 3/8” Quick Dis- connect fitting and have integral shut-off valves. 80 PSI is the maximuum air pressure. Do not exceed the maximum air pressure.
  • Page 9: Operation - Stage 1

    oPeRaTIon - sTage 1 Receiving/Cleaning/Decontamination 1. The 30” tall upper instrument staging area is equipped with three shelves to store contaminated instruments. The optional pneumatic foot pedal, located at the base of the optional waste module, opens the upper storage doors.
  • Page 10: Operation - Stage 1 (Continued)

    oPeRaTIon - sTage 1 (ConTInUeD) 7. The double glove dispenser can accommodate two standard glove boxes. Simply slide the boxes face down under the clamps and over the openings. 8. Insert a tissue box face down or single sheets of paper towels over the opening in the tissue/towel dispenser.
  • Page 11: Operation - Stage 2

    oPeRaTIon - sTage 2 Preparation and Packaging Area 1. Wrapping Station: Preparation and packaging in Stage Stage 2 2 allows the user to wrap and package up to 24” X 24” wraps and room for packaging large and small cassettes. The two top drawers pull out to a work space for this operation.
  • Page 12: Operation - Stage 3

    oPeRaTIon - sTage 3 Stage 3 Sterilization Area 1. The two or three 1” solid surface shelves with drip-proof troughs fully extend out and are at a lower height for all-user access. These shelves resist heat and moisture when sterilizing instruments.
  • Page 13: Operation - Stage 4

    oPeRaTIon - sTage 4 Sterile Storage Stage 4 is a clean storage tower that is equipped with five adjustable racks. The tower swivels to 180 degrees for easy access to clean and sterilized essentials. 1 / 2 1. The four viewing panels allow easy inspection of contents. 2.
  • Page 14: Cleaning, Disinfecting & Sterilization

    CleanIng, DIsInfeCTIng & sTeRIlIZaTIon Equipment can be cleaned with a solution of mild detergent and warm water. A variety of surface IMPoRTanT: Do not use powdered cleansers, disinfectants are available for use in dental treatment scouring pads or abrasive scrubbers on any of the rooms.
  • Page 15: Vacuum Instruments

    VaCUUM InsTRUMenTs After Each Patient Draw clear water through each valve, while opening and closing it several times. Leave the valve open for several seconds to allow all of the water to clear the hoses. The HVE and Saliva Ejector tips should always be replaced with sterile ones before each patient.
  • Page 16: Cleaning Cabinetry Surfaces

    CleanIng CabIneTRY sURfaCes Disinfecting the Surfaces Cleaning Stainless Steel Fixtures Disinfect cabinet surfaces by spraying or wiping with sur- Clean surface using warm water with a mild, non- face disinfectant using the spray-wipe-spray technique scratching abrasive powder such as typical household as endorsed by OSAP (Office Sterilization and Asepsis cleanser.
  • Page 17: Adjustments

    aDJUsTMenTs Door Hinge adjustment The doors are adjusted at the factory so the doors open and close properly. However, an occasional adjustment may be required over a period of usage. Unsnap hinge cover from hinge. Using a green handle screw driver from grass or a #2 posi-drive driver only, adjust doors as follows: Screw 1 will move the door SIDE to SIDE.
  • Page 18: Notes

    noTes 042281 R03...
  • Page 19 ©2014 11727 Fruehauf Drive P/N 042281 Rev. 03, 04/21/14 Charlotte, NC, 28273 - USA Printed in USA We reserve the right to make any alterations which may be due to any technical improvements...