Setec Power SET-IVS9000 Series System Manual

Sine-wave inverter

Advertisement

Quick Links

SET-IVS9000 Series Sine-Wave Inverter
SET12/220-XXXX KLC
SET24/220-XXXX KLC
SET48/220-XXXX KLC
SET110/220-XXXX KLC
SET220/220-XXXX KLC
Shenzhen SETEC Power Co., Ltd
Address: #199, Setec Industrial Park, Dakan, Xili Town, Nanshan District,
Shenzhen ,China
Tel: 0755-26527891, 26527426, 26527137
Fax: 0755-26527104
Web: http://www.setec.com.cn
http://www.setec-power.com
System Manual
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SET-IVS9000 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Setec Power SET-IVS9000 Series

  • Page 1 SET-IVS9000 Series Sine-Wave Inverter SET12/220-XXXX KLC SET24/220-XXXX KLC SET48/220-XXXX KLC SET110/220-XXXX KLC SET220/220-XXXX KLC System Manual Shenzhen SETEC Power Co., Ltd Address: #199, Setec Industrial Park, Dakan, Xili Town, Nanshan District, Shenzhen ,China Tel: 0755-26527891, 26527426, 26527137 Fax: 0755-26527104 Web: http://www.setec.com.cn...
  • Page 2 【Precautions】 Before operating, please read the users manual to learn the proper use of Please keep this manual for future use equipment. Warning: The machine should be installed by trained engineers, please make sure to clarify the following issues before installation: ...
  • Page 3: Table Of Contents

    2. SET-IVS9000 SERIES FEATURES ............. 1 3. SET-IVS9000 SERIES MODEL NOTES: ..........2 4. SET-IVS9000 SERIES MODEL TABLE ..........2 5. SET-IVS9000 SERIES INTERNAL BLOCK DIAGRAM ...... 3 6. SET-IVS9000 SERIES MODEL USE METHOD ........3 7. SET-IVS9000 SERIES MAINTENANCE INFORMATION ....4 8.
  • Page 4: Set-Ivs9000 Series Summarize

    AC input use multiple filtering technology to eliminate mains interference, which meet the application needs of using main AC power; SET-IVS9000 series inverter has 2 working types: AC power type and DC power type (It can be modified via LCD panel or communication background software);...
  • Page 5: Set-Ivs9000 Series Model Notes

    (optional); 11) SET-IVS9000 series inverter supports TCP / IP protocol functions. It uses monitoring software to remote control single / multiple inverters via Ethernet(optional); 12) SET-IVS9000 series inverter provides three sets of passive dry contacts (with separate dry contact interface), respectively for the DC input failure (1,2 pin), AC input failure (5,6 pin) and AC output failure (3,4 pin) alarms.
  • Page 6: Set-Ivs9000 Series Internal Block Diagram

    5. SET-IVS9000 Series Internal block diagram 6. SET-IVS9000 Series Model Use Method 6.1 Preparation (To install the inverter, it requires technical staff who has some knowledge of electrical theory and practical experience) a) Open the package and check accessories b) Choose a clean and ventilation area.
  • Page 7: Set-Ivs9000 Series Maintenance Information

    The are 3 kinds of communication interface: RS232, RS485 ,TCP / IP, but only choose on from them .Baud rate is up to 9600. 7. SET-IVS9000 Series Maintenance information Button and the Definition of LED light On / off button—SWITCH "Power output"...
  • Page 8 Chart 1: Indicator and Combination ((F)BAC12A (F)BDC12A (F)BAC35A (F)BDC35A ) Status Output Power Inverter Battery Load Output Buzzer Item Type Green Blue Power A sound/1s →On→ →On→ →On→ →On→ Self Test 3sound/ Inverter muted Self Test Power Battery Dark Light Blink Dark Blew...
  • Page 9: Set-Ivs9000 Series Lcd Menu Content

    , it does not affect the device performance . (Or consult manufacturer technical person). Explain: "→" means the LED lights up in order; " Note " to Chart II SET-IVS9000 Series LCD menu content Menu Display: Press Menu button: down DC voltage: current DC input voltage...
  • Page 10: Set-Ivs9000 Series Model Technical

    9. SET-IVS9000 Series Model Technical Specifications Chart 2:SET-IVS9000 Series Model Technical Specifications Technical Specifications (VA) 0.5K Input Voltage(Vdc) See chart3 Input current(A) See chart3 Input range of DC INPUT See chart3 Voltage(Vdc) Reflected Noise ≤10% Current Bypass Volt(Vac) 260V-180V(±10V) AC Bypass Input Current(A)...
  • Page 11 Protection Function Reversed Input Connecting Protection Note: Rated output power error: 500VA to ± 50W; 1-5KVA to ± 100W; 6KVA to ± 200W Chart 3:SET-IVS9000 Series inverter input DC voltage, current, efficiency (error: ± 2V/± 2%) SET12 Series SET24 Series...
  • Page 12: Set-Ivs9000 Series Mechanical Properties

    10. SET-IVS9000 Series Mechanical properties Figure 1:0.5K-3KVA Mechanical info(2U/19 Inch Rack Type LCD Panel) Machine Model: 500VA Size: 482*375*88 (W*D*H) Weight: 5Kg 1KVA Size: 482*375*88 (W*D*H) Weight: 8Kg 2KVA Size: 482*375*88 (W*D*H) Weight: 8Kg 3KVA Size: 482*375*88 (W*D*H) Weight: 10Kg Figure 2:4K-5KVA Mechanical info(2U/19 Inch Rack Type LCD Panel)...
  • Page 13: Accessory

    Figure 3:6K-10KVA Mechanical info (4U/19 Inch Rack Type LCD Panel) Machine Model: 6KVA Size: 482*400*176 (W*D*H) Weight: 15Kg 7KVA Size: 482*400*176 (W*D*H) Weight: 15Kg 8KVA Size: 482*400*176 (W*D*H) Weight: 17Kg 10KVA Size: 482*400*176 (W*D*H) Weight: 17Kg Fingure 4: 48Vdc-10KVA Mechanical info(8U/19 Inch Rack Type LCD Panel) 11.
  • Page 14: Note

    3)Mounting holes screws: 4 pcs, factory inspection report. 12. Note Please understand that due to constantly update the product, the content of this document does not exactly match the actual product. For product updates, please contact us. Chart 4: Inverter common fault analysis table Fault type Symptom Fault Analysis...
  • Page 15: Quality Assurance Card

    Quality assurance card Before leaving the factory, we ensure the sine wave inverter quality is excellent and it must be strictly checked. The company assures customers a good machine performance, mechanical integrity. One-year free warranty service, warranty are as follows: In one-year warranty period, if mechanical damage and failure occure, we will provide free repair and replacement parts, when the company's technical staff confirmed that the it is occurring under normal use.