IOTA B Series Instruction Manual

Compact lamp emergency lighting equipment

Advertisement

Quick Links

P.O. BOX 11846 TUCSON, AZ 85734
(520) 294-3292
• FAX (520) 741-2837
www.iotaengineering.com
INSTRUCTION MANUAL

IMPORTANT SAFEGUARDS

When using electrical equipment, basic safety precautions should always be followed, including the following:
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
1.
CAUTION – To prevent electrical shock, do not mate unit connector until installation is complete and A.C.
power is supplied to the unit.
2.
CAUTION – This fixture provides more than one power supply output source. To reduce the risk of electrical
shock, disconnect both normal and emergency sources by turning off the A.C. branch circuit and by discon-
necting the unit connector.
3.
CAUTION – This is a sealed unit. The integral, high temperature Ni-Cad battery is not replaceable. Replace
the entire unit when necessary and recycle or dispose of the nickel-cadmium battery properly.
4.
DO NOT USE OUTDOORS. The I-13-EM-A is for use with grounded, UL Listed, damp location rated, indoor
fixtures. Not for use in heated air outlets or hazardous locations.
5.
The I-13-EM-A requires an unswitched A.C. power source of either 120 or 277 volts. Properly cap the unused
A.C. lead.
6.
The I-13-EM-A and A.C. ballast must be on the same branch circuit.
7.
Do not mount near gas or electric heaters.
8.
The I-13-EM-A should be mounted in locations and at heights where it will not readily be subjected to tamper-
ing by unauthorized personnel.
9.
The I-13-EM-A will cold strike and operate one 5W, 7W, or 9W, twin tube, double twin tube, 180ma or 13W
twin tube, double twin tube, 285ma fluorescent lamp, each with a single lampholder per lamp.
10.
The I-13-EM-A is for use with fluorescent downlight fixtures.
11.
Suitable for use in damp locations.
12.
For use in 0° C minimum, 50° C maximum ambient temperatures.
13.
The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition, void
warranty, and result in non-compliance with UL specifications.
14.
Do not use this equipment for other than intended use.
15.
Install in accordance with the National Electrical Code and local regulations.
16.
Installation and servicing should be performed by qualified personnel.
17.
Lighting fixture manufacturers, electricians, and end-users need to ensure product system compatibility before
final installation.
SAVE THESE INSTRUCTIONS
I-13-EM-A
SERIES D
COMPACT LAMP
EMERGENCY
LIGHTING EQUIPMENT

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the B Series and is the answer not in the manual?

Questions and answers

Summary of Contents for IOTA B Series

  • Page 1 I-13-EM-A SERIES D COMPACT LAMP EMERGENCY P.O. BOX 11846 TUCSON, AZ 85734 LIGHTING EQUIPMENT (520) 294-3292 • FAX (520) 741-2837 www.iotaengineering.com INSTRUCTION MANUAL IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS CAUTION –...
  • Page 2 INSTALLATION INSTRUCTIONS CAUTION: Before installing, make certain the A.C. power is off and the I-13-EM-A unit connector is disconnected. 1. MOUNTING THE I-13-EM-A When used with ceiling mounted downlight fixtures, the I-13-EM-A should be mounted on the fixture above the ceiling.
  • Page 3 with switched fixtures, the I-13-EM-A input must be wired ahead of the switch. C. Refer to the wiring diagrams on the back page for the proper wiring. For wiring diagrams of ballasts not shown, consult our customer service. 4. LABELS Attach the appropriate labels adjacent to the Test Switch and Charge Indicator.
  • Page 4 TYPICAL WIRING DIAGRAMS For use with 2 pin, 5 through 13 watt lamps with integral starter only. Wiring and Troubleshooting Tips are available on-line at http://www.iotaengineering.com/wiringtips.pdf 1. ONE LAMP MAGNETIC BALLAST 2. ONE LAMP HIGH POWER FACTOR MAGNETIC BALLAST BLK (120V) TEST UNSWITCHED LINE SWITCH...
  • Page 5 TYPICAL WIRING DIAGRAMS For use with 2 pin, 5 through 13 watt lamps with integral starter only. Wiring and Troubleshooting Tips are available on-line at http://www.iotaengineering.com/wiringtips.pdf 9. TWO NORMAL POWER FACTOR MAGNETIC BALLASTS BLK (120V) TEST UNSWITCHED LINE SWITCH ➀ WHITE ORG (277V) EMERGENCY...

This manual is also suitable for:

I-13-em-a25082260

Table of Contents