Download Print this page
Hide thumbs Also See for SA-3:

Advertisement

Quick Links

Owner's Manual
SA-3 to SA-6C32
Our technology gives WATER a second life;
We ReNEWater !

Advertisement

loading

Summary of Contents for Bionest SA-3

  • Page 1 Owner’s Manual SA-3 to SA-6C32 Our technology gives WATER a second life; We ReNEWater !
  • Page 2 We reserve the right to add, modify or change any technical specification of our products, as well as prices, without prior notice. All trademarks shown are property of Bionest Technologies inc. and used under license. The BIONEST® technology, its process and their use are protected under the EP 1 430 000 B1 European patent throughout the 27 countries members of the European Patent Office, patents 7 578 398 and 7 582 211 in the United States, 2 461 668 in Canada, 602197 in New Zealand and by patents pending in the United States, in Europe and according to the patent cooperation treaty.
  • Page 3 perating principles OmpOnents mpOrtant Operating instructiOns aintenance rOubleshOOting arranty certificate Owner’s manual SA 2021-06-07 DOC0014...
  • Page 4 The BIONEST® advanced secondary system uses a technology which replicates an accelerated natural purification process normally occurring in the ground. This biological process takes place in a restricted and controlled environment removing organic and microbial pollutants harmful to your health and the environment. This system is used for treatment of domestic type wastewaters.
  • Page 5 The BIONEST® system uses a biological process consisting of a synthetic media on which clings a bacterial biofilm. The media is a non-toxic patended polymer ribbon, scored to promote growth of the bacterial biofilm. Illustration 2: BIONEST® system components BIONEST® Media...
  • Page 6 As required by the Regulation respecting wastewater disposal systems for isolated dwellings (Q-2, r. 22), the BIONEST® system is certified according to NQ 3680-910 standard for six (6) bedroom or less dwellings. Bionest offers six (6) certified models for isolated dwellings, according to the number of bedrooms, as well as for buildings generating a daily flow between 2,161 L/d and 3,240 L/d.
  • Page 7 HP-80 model : 71 Watts; HP-100 model : 75 Watts; HP-200 model: 250 Watts Recirculation pump A recirculation pump is installed inside the BIONEST® reactor’s last compartment and returns part of the treated effluent back to the septic tank inlet. This ensures several contacts between wastewaters and purifying bacteria, thus improving the treatment performance level.
  • Page 8 Alarm The BIOLARM® control system detects any malfunction of the BIONEST® system’s electrical components, such as the recirculation or aerator (air pump). It also signals any abnormality related to a high water level detected by the BIO-UV , the BIO-PUMP or by an effluent filter high level float, where applicable.
  • Page 9 Identification plate An identification plate located on the BIOLARM® casing of your SA system shows your system’s own specifications; please make sure you have this information on hand whenever you call Bionest. Your BIONEST® system serial number Owner’s manual SA 2021-06-07...
  • Page 10 The integrated BIO-UV disinfection unit is preassembled and installed in the last compartment of the BIONEST® reactor. Treated water is gravity drawn. The BIOLARM® visual and sound alarm is activated in case of a UV lamp failure or a high water level in the reactor. Ultraviolet rays penetrate fecal coliforms for an efficient destruction reaching a quality level above swimming water standards.
  • Page 11 Before starting the aerator and recirculation pump, make sure the septic tank and BIONEST® reactor are completely filled with clear water. Using your system when the air pump is not operating may cause serious consequences (exterior odors, clogging of polishing field, warranty cancellation).
  • Page 12 USE. IT IS FORBIDDEN : To alter the configuration of your septic installation and/or of your BIONEST® treatment system. Should you engage in any landscaping activity, please inform your contractor of the location of your septic installation to avoid any damage.
  • Page 13 • There are underground pipes and electrical wires close to your septic installation. BEFORE digging or undergoing any work within this area, please contact your installer. • Power supply must always be cut off prior to any maintenance activity on any BIONEST® electrical component.
  • Page 14 In case of a system with UV disinfection, a copy will also be sent to your local authorities. The BIONEST® system must remain accessible at all times. It is your responsibility to provide quick and easy access to all covers...
  • Page 15 Septic tank Effluent filter Upon the maintenance visit, the Bionest authorized representative will clean the effluent filter. Cleaning of the effluent filter is normally required twice a year, but may require additional cleaning, should an important deposit be noticed on the effluent filter.
  • Page 16 BIONEST® reactor Aerator (air pump) The filter of each aerator (air pump) must be cleaned periodically. According to the aerators (air pumps) location (dusty area), a more frequent cleaning by the owner may become necessary; a clogged filter may cause overheating or pump failure. To clean the air filter: 1.
  • Page 17 12 month operating period be replaced; such replacement must be performed by an authorized Bionest representative. After a six (6) month operating period of the UV lamp, it will also be cleaned by an authorized Bionest representative.
  • Page 18 NOTE : Bionest’s responsibility is limited to the BIONEST® system components. Bionest is not responsible for on-site installation of said components. BEFORE CALLING BIONEST, PLEASE REFER TO ABOVE INDICATIONS : IT COULD SAVE YOU THE COST OF A SERVICE VISIT.
  • Page 19 Low pressure in the air Contact Bionest • )))) supply line Reduce water consumption and Double flashing indicator Auxiliary (UV) contact Bionest immediately • )) )) Continuous indicator Low pressure in the air supply Reduce water consumption and line AND auxiliary problem contact Bionest To stop alarm Press the "Silence Air"...
  • Page 20 Water recirculation pump Contact Bionest • )))) stoppage Reduce water consumption Double flashing indicator High water level inside tank and contact Bionest immediately • )) )) Continuous indicator Water recirculation pump Reduce water consumption stoppage AND high water and contact Bionest...
  • Page 21 Bionest global responsibility associated with a defective product will, in all cases, be limited to replacement of said defective product. Such limitations are applicable independently of the basis of the claim or the petition in court. Bionest reserves the right to use Owner’s manual SA...
  • Page 22 (or parts) for repair or replacement within this warranty. Such products and parts are similar in functionality and performance to original product or part, as determined by Bionest at its sole discretion and are covered under the present warranty conditions.
  • Page 23 BIONEST® system, without Bionest’s written approval. • Any damage or problem if it is shown that the BIONEST® system was not used according to instructions in the owner’s manual. • Any damage or problem if maintenance of the BIONEST® system was not performed according to Bionest recommendations.
  • Page 24 Damage limitation Bionest may in no way be held liable for any other damage sustained by the client or third party; Bionest’s compensation or indemnification obligation shall be limited to the provisions under this agreement.
  • Page 25 If the client or the client’s successors requests an inspection by Bionest in regards to a warranty claim and it is found, upon duly authorized inspection, for the validity of the aforementioned warranty claim, that the BIONEST®...
  • Page 26 I also declare that I have read the warranty certificate provided by Bionest regarding the BIONEST® system, SA model, and wish to benefit from this warranty coverage for the remaining period, if applicable, and from the maintenance agreement. I accept all terms and conditions therein and ask Bionest to take note of this transfer of ownership.

This manual is also suitable for:

Sa-4Sa-5Sa-6Sa-6c27Sa-6c32