IFM Electronic OVP800 Operating Instructions Manual
IFM Electronic OVP800 Operating Instructions Manual

IFM Electronic OVP800 Operating Instructions Manual

Image processing system

Advertisement

Quick Links

Operating instructions
GB
Image processing system
OVP800
M03975

Advertisement

Table of Contents
loading

Summary of Contents for IFM Electronic OVP800

  • Page 1 Operating instructions Image processing system OVP800 M03975...
  • Page 2: Table Of Contents

    OVP800 M03975 Image processing system Contents Preliminary note .............
  • Page 3: Preliminary Note

    Device of protection class III. Only for operation in PELV circuits. 1.4 Legal and copyright information © All rights reserved by ifm electronic gmbh. No part of these instructions may be reproduced and used without the consent of ifm electronic gmbh.
  • Page 4 FOR A PARTICULAR PURPOSE. See the GNU General Public License and the GNU Lesser General Public License for more details. The responsibility of ifm electronic gmbh for ifm products, in the case of product-specific software, remains unaffected by the above disclaimer. Please note that the firmware for the ifm products is in some cases provided free of charge.
  • Page 5: Safety Instructions

    Image processing system OVP800 M03975 2 Safety instructions • The unit described is a subcomponent for integration into a system. – The system architect is responsible for the safety of the system. – The system architect undertakes to perform a risk assessment and to create documentation in accordance with legal and normative requirements to be provided to the operator and user of the system.
  • Page 6: Intended Use

    OVP800 M03975 Image processing system 3 Intended use The device is an image processing system that processes data from connected camera heads. After processing the data, the output values are calculated and sent to the higher-level system. The device is required for the operation of the connected camera heads.
  • Page 7: Installation

    Image processing system OVP800 M03975 4 Installation 98,7 Fig. 1: Rear of the unit with the threaded M5 holes Mounting the unit: u Mount the unit on a mounting plate using the 4 threaded M5 holes. w Observe the maximum tightening torque of 5.5 Nm for the threaded holes.
  • Page 8: Electrical Connection

    OVP800 M03975 Image processing system 5 Electrical connection ATTENTION The unit must be connected by a qualified electrician. Protection class III (PC III) unit (IEC 61010-2-201 chap. 6.5.2.101.4). The electrical supply must - be provided only by PELV circuits (IEC 61010-2-201 chap. 3.111),...
  • Page 9: Wiring

    Image processing system OVP800 M03975 5.1 Wiring Fig. 2: Wiring 1 Power supply / CAN 2 2x Ethernet RJ45 3 Mini USB interface 2.0 4 USB interface 5 Sensor port 0 to port 5 (from left to right) Power supply / CAN, M12 connector, A-coded, 5 poles 1: screen 2: 24 V...
  • Page 10: Operating And Display Elements

    OVP800 M03975 Image processing system 6 Operating and display elements Fig. 3: Light indicators 1 Power LED 2 Status LED 3 Ethernet LED 4 Sensor status LEDs 6.1 Signal indications Power LED Power LED (green) Description Device switched on Device switched off. Status LED...
  • Page 11: Parameter Setting

    Image processing system OVP800 M03975 7 Parameter setting The camera parameters can be set in two ways: • ifmVisionAssistant software, available for download: www.ifm.com • Code examples, available for download in the developer portal: www.ifm3d.com...
  • Page 12: Operation

    OVP800 M03975 Image processing system 8 Operation Before set-up, the device must be configured: u Configure the device using the ifmVisionAssistant software. w The software is available for download: www.ifm.com 30 seconds after switching on the power supply, the configured device will be in operation. The operating and display elements show the status of the unit and the connected sensors.
  • Page 13: Maintenance, Repair And Disposal

    Image processing system OVP800 M03975 9 Maintenance, repair and disposal Maintenance If used correctly, the unit is maintenance-free. Cleaning agents containing solvents and silicone may damage the unit. u Only use cleaning agents without solvents and silicone. Repair Only the manufacturer is allowed to repair the unit.
  • Page 14: Approvals/Standards

    OVP800 M03975 Image processing system 10 Approvals/standards For approvals and standards, the following information is available: • Test standards and regulations: documentation.ifm.com • EU declaration of conformity and approvals: documentation.ifm.com • Notes relevant for approval: package inserts of the device...

This manual is also suitable for:

M03975

Table of Contents