Operation Manual RehaStim 2, RehaMove 2
Version 2.4 / 2016-10
Hasomed GmbH
User Guide

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RehaStim 2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Hasomed RehaStim 2

  • Page 1 Operation Manual RehaStim 2, RehaMove 2 Version 2.4 / 2016-10 Hasomed GmbH User Guide...
  • Page 2: Table Of Contents

    5 Data Storage in the Stimulator ........................35 6 RehaMove Training - Integrated Operation (FES 3-Interface) ........................36 Create new Users and new User Profiles, import old Profiles ................................. 37 Edit or delete a User Profile ................................. 42 Constant Stimulation Training ................................. 45 HASOMED GmbH...
  • Page 3 Adjusting the external double Trigger ................................. 82 7 Edit or delete a User Profile, show Training History ........................83 8 Finishing a Stimulation Session ........................83 Part 7 Fault Indication Part 8 Declaration of Warranty Part 9 Address of Manufacturer HASOMED GmbH...
  • Page 4: Part 1 General Description

    Operation Manual RehaStim2, RehaMove2 General Description Declaration of Conformity Version 2.4 / 2016-10 HASOMED GmbH...
  • Page 5: Description Of The Rehastim2

    6. Stimulation should not be applied over swollen, infected, or inflamed areas or skin eruptions, e.g., phlebitis, thrombophlebitis, varicose veins, etc. 7. Stimulation should not be applied over, or in proximity to, cancerous lesions. HASOMED GmbH Version 2.4 / 2016-10...
  • Page 6 Read the manual carefully before using this device! The RehaStim2 is classified as a medical device type IIa. An inspection of the device must be carried out by the HASOMED service staff only. You are not allowed to open the device. The repair of the RehaStim2 must be performed by...
  • Page 7 The arm crank should not be used unless continuous assistance is available as while using this device it may not be possible for the client to stop the therapy while their arm(s) / hand (s) are secured. HASOMED GmbH Version 2.4 / 2016-10...
  • Page 8: Indications And Contra Indications

    Indications of use Clients' interventions can have a variety of goal such as: Relaxation of muscle spasms Prevention or retardation of disuse atrophy Increasing local blood circulation Maintaining or increasing of range of motion Version 2.4 / 2016-10 HASOMED GmbH...
  • Page 9 Pressure sores or open wounds in the area of treatment. Implants: Recently (< 3month) implanted plates, pins, screws and other hardware underneath or near the muscle groups which are to be stimulated. HASOMED GmbH Version 2.4 / 2016-10...
  • Page 10: User Safety

    Do not use when user is simultaneously connected to a high-frequency surgical unit, because this may lead to burns underneath the electrodes. Do not use near (within 1.5m) devices with high frequency (HF) range or micro- and Version 2.4 / 2016-10 HASOMED GmbH...
  • Page 11 All accessories which are not provided by HASOMED GmbH and which the user wants to connect to the interfaces of the unit, must verifiably meet the according EN specifications (e.g.
  • Page 12: Adverse Reactions

    LCD- Display/ keypad, turning knob Communications USB / ODU Medi Snap Operation system Special Software Maximum voltage output 154 V Maximum number of channels Current output per channel 0 – 130 mA in 65 steps Version 2.4 / 2016-10 HASOMED GmbH...
  • Page 13 · In use +5 °C to +40 °C · Relative humidity RH 15% to 93%, non condensing · Transporting/ storing -25 °C to +70 °C · Relative humidity RH 70% to 93%, non condensing HASOMED GmbH Version 2.4 / 2016-10...
  • Page 14 · In use +5 °C to +40 °C · Relative humidity RH 15% to 93%, non condensing · Transporting/ storing -25 °C to +70 °C · Relative humidity RH 70% to 93%, non condensing Version 2.4 / 2016-10 HASOMED GmbH...
  • Page 15: Default Values

    200° to 360° triceps - left TB_L 40° to 190° biceps - left BB_L 0° to 360° individual Ind1 0° to 360° individual Ind2 0° to 360° individual Ind3 0° to 360° individual Ind4 HASOMED GmbH Version 2.4 / 2016-10...
  • Page 16: Features

    The manufacturer recommends for the stimulator a maintenance interval of 2 years in order to guarantee the safety standards for further use. Hence, please send your RehaStim2 on your own account to the manufacturer. HASOMED will examine the adherence to technical parameters and the function of the monitoring elements.
  • Page 17: Part 2 What's New In This Software Version

    Starting from version 2.4, the connection to MOTOmed motion trainer is only possible via FES3-Interface. Separate operation of RehaStim2 and MOTOmed is no longer possible. All settings during FES-training are carried via the RehaStim2. HASOMED GmbH Version 2.4 / 2016-10...
  • Page 18: Part 3 Device Controls And Accessories

    The grey connector is used for the Qick Stop The white connector is used for the connection cable to the MOTOmed or for the external trigger in sequence mode. The yellow and green connectors are used for corresponding electrode cables. Version 2.4 / 2016-10 HASOMED GmbH...
  • Page 19: Accessories

    1 cable to connect the movement exerciser and RehaStim2 Separately: bracket with screws to fix the stimulator onto the motion trainer For sequence training/ general stimulation, if requested: an external trigger For ScienceMode2: 1 USB connection cable to PC HASOMED GmbH Version 2.4 / 2016-10...
  • Page 20 Electrode cables The electrode cables connect the stimulator to the surface electrodes. Each electrode cable is divided into 4 channels with 2 electrodes each. The channels are color coded and thus mix-up proof. Version 2.4 / 2016-10 HASOMED GmbH...
  • Page 21 RehaTrode electrodes only! manufacturer HASOMED guarantees for the safe use of the RehaMove2 only with these electrodes. The RehaTrode is tailored to the operation with the stimulator RehaStim2. Due to the technical data of the RehaStim2, an overload of the RehaTrode by the initial values of the RehaStim2 is not possible.
  • Page 22 Operation Manual RehaStim2, RehaMove2 A patented two-layer adhesive gel prevents problems in quality as known from single-layer gels. Hasomed Item Number Description FES00200 RehaTrode 2.0” x 3.5”, 5cm x 9 cm, rectangle FES00201 RehaTrode 3.0” x 5.0”, 7,5cm x 13 cm, rectangle FES00202 RehaTrode 1.5”...
  • Page 23: Part 4 General Settings And Service Information

    Switch on the stimulator by pressing the on/off button. The device control lamp indicates with a green light that the stimulator is switched on. The HASOMED RehaMove2 logo appears on the LCD color screen. The stimulator starts loading the program and a few seconds later the window "Choose user" appears.
  • Page 24: System: Device Settings, Backup & Restore, Password

    If the knob is turned, entries are changed. If the knob is pressed, entries are confirmed and the next field is ready to be set. After the last field is set, the stimulator restarts with the time updated. Version 2.4 / 2016-10 HASOMED GmbH...
  • Page 25 How and when to assign profiles to users: see chapter Create new Users and new User Profiles One user mode Activate one user mode for home users. Deactivate it for clinical /multiple users. There is no password protection in one user mode! HASOMED GmbH Version 2.4 / 2016-10...
  • Page 26 O n ly th e th erapist is allow ed to activate an d deactivate th e passw ord protection . There is no password protection in one user mode! Should the password be lost or forgotten contact the manufacturer. Version 2.4 / 2016-10 HASOMED GmbH...
  • Page 27: Motomed: Reference Angle, Fes3 Protocol, Fes3 Test

    - if the MOTOmed viva2 cockpit/controller has been exchanged or - if the stimulator was moved to a different MOTOmed viva2. Warning! The zero angle is a device specific parameter and not part of the individual parameters. HASOMED GmbH Version 2.4 / 2016-10...
  • Page 28 Press the test button in order to run a test of the successful communication between stim MOTOmed in FES3 mode. The test lasts about 5 minutes! If there are issues, a popup window hints you how to solve these. Version 2.4 / 2016-10 HASOMED GmbH...
  • Page 29: Mounting Instruction For Stimulation Bracket

    Place the bracket tube to the fixed black PVC part. Now tighten the cap nuts with the enclosed jaw spanner. Put the stimulator plate onto in the bracket tube. Make sure that the bevelled edge points downward. HASOMED GmbH Version 2.4 / 2016-10...
  • Page 30 M6x55. To fix them use the allen key size 5. Fix the bracket tube to the black PVC part with the four remaining screws. To fix them use the allen key size 4. Version 2.4 / 2016-10 HASOMED GmbH...
  • Page 31 Mount the black PVC part to the MOTOmed’s gracile cockpit standpipe with the two enclosed screws and the cap nuts. To fix them use the allen key size 5 and the Jaw spanner size 10. HASOMED GmbH Version 2.4 / 2016-10...
  • Page 32 Mount the stimulator with the two knurled screws onto the stimulator plate. The stimulator and the stimulator plate must line up precisely with each other. Connect the stimulator and the accessorries as described in chapter "Device Controls and Accessories" Version 2.4 / 2016-10 HASOMED GmbH...
  • Page 33: Mounting Instruction For Power Supply Holder

    Do not remove the fixation if you like to disconnect the power supply from the power source. Only disconnect the power cord which connects the power supply with the power source. HASOMED GmbH Version 2.4 / 2016-10...
  • Page 34: Part 5 Rehamove2-Fes Cycling

    The session should finish with a cool down phase. The RehaMove programs realize this course automatically, the duration of these three phases can be adapted user individually. Version 2.4 / 2016-10 HASOMED GmbH...
  • Page 35: Safety Measures Before You Start

    GmbH. Use only properly earthed power outlets. Use only the original power supply delivered by the manufacturer HASOMED GmbH. If an electric cable has been damaged, stop session immediately and contact the manufacturer. Connect cables in a way that no person walking by could get caught in the cables and these cannot get into the rotating pedals and be damaged.
  • Page 36: Recommended Adjustments

    The use of a client individual USB simplifies the operation, as the client will only see his/ her own profiles. After the session, the training history is automatically stored in the stimulator as well as on the USB. Version 2.4 / 2016-10 HASOMED GmbH...
  • Page 37: Home Use

    Start in window "Choose user". Press button "System" / go to tab "System" / press button "Advanced". One user mode Activate one user mode. I.e. One user mode should be Password protection Turn the password protection to OFF. HASOMED GmbH Version 2.4 / 2016-10...
  • Page 38: Data Storage In The Stimulator

    The number of the profile files per user is not limited. Note: Do not change file names manually to avoid data loss! Only the Hasomed RehaMove USB flash drive may be used to store data. Backup and Restore User data via USB Create a Backup from the stimulator onto your USB flash drive.
  • Page 39: Rehamove Training - Integrated Operation (Fes 3-Interface)

    Futhermore you see a small figure above the turning knob. If you press the knob, a pop up will display the template of the selected profile with the electrode positioning. This option is not available in individual electrode placements. HASOMED GmbH Version 2.4 / 2016-10...
  • Page 40: Create New Users And New User Profiles, Import Old Profiles

    Transparent buttons are not active and cannot be pressed. Use buttons: RehaMove Arm: Arm training with RehaMove RehaMove Leg: Leg training with RehaMove Sequence: sequence mode with RehaStim as stand-alone Version 2.4 / 2016-10 HASOMED GmbH...
  • Page 41 Choose whether 2, 3 or 4 channels - or 4, 6 or 8 in a bilateral template - shall be used for stimulation. Use the turning knob in order to select one template. Press Next to confirm your entries. HASOMED GmbH Version 2.4 / 2016-10...
  • Page 42 In order to confirm entries, press the turning knob Use buttons: Angles: to see/ change angles for the program Back: to cancel the process / go back to the previous window Next: to activate further muscle groups or adjust parameters Version 2.4 / 2016-10 HASOMED GmbH...
  • Page 43 Press the button Warm up in order to change the duration of the warm up. A field above the turning knob pops up with the present value in minutes. Use the turning knob: HASOMED GmbH Version 2.4 / 2016-10...
  • Page 44 The re is no stim ula tion during Se ttings. U se curre nt te st to ve rify the stim ula tion pa ra m e te rs. The activated key will be deactivated by pressing the button next to the green marked field. The next Version 2.4 / 2016-10 HASOMED GmbH...
  • Page 45: Edit Or Delete A User Profile

    Next. Note: Th is screen does n eith er appear in on e u ser m ode n or w h ile u sin g th e patien t USB. HASOMED GmbH Version 2.4 / 2016-10...
  • Page 46 Note: Th e u ser w ill be au tom atically deleted on th e USB flash drive, if th e u ser is deleted on th e stim u lator an d th e USB is con n ected to it at th is tim e. Version 2.4 / 2016-10 HASOMED GmbH...
  • Page 47 RehaMove2-FES Cycling For editing the profile You enter the profile creation in the window "channel configuration" . Continue as described in chapter “Create a new user program”. HASOMED GmbH Version 2.4 / 2016-10...
  • Page 48: Constant Stimulation Training

    Use buttons: Resistance: adjust the resistance level of the MOTOmed viva 2 Speed (rpm): adjust the speed of the MOTOmed viva 2 Break: Pause the warm up Stimulation: Stop the warm up and start stimulation Version 2.4 / 2016-10 HASOMED GmbH...
  • Page 49 The current feedback screen stops by pushing the pin button. The pin symbol is replaced by the arrow symbol. The next feedback screen appears if the user taps the button within 5s again. The user gets back into switch HASOMED GmbH Version 2.4 / 2016-10...
  • Page 50 If one channel is selected, it is marked green and a bar with set current in mA pops up in the middle of the screen. Use the turning knob: Change the current by turning the knob Version 2.4 / 2016-10 HASOMED GmbH...
  • Page 51 End shows the end of pause intervals. Duration/Period shows pause in minutes. Press button Save to store the adjustments. These adjustments allow a reaction on clients' individual muscle fatigue during stimulation and helps to complete a whole therapy session. HASOMED GmbH Version 2.4 / 2016-10...
  • Page 52 The report shows the times for warm up, stimulation and cool down as well as the entire duration of breaks during the session, and the energy consumption in kcal. Use buttons: Next : Close the report and go to window “Select application” Version 2.4 / 2016-10 HASOMED GmbH...
  • Page 53: Adaptive Stimulation Training

    20 rpm, resistance level: 0 (zero) Start the movement exerciser and leave it in the start screen. No further operation is allowed! Turn on the stimulator and start training. Speed of the MOTOmed must be at least 10 rpm. HASOMED GmbH Version 2.4 / 2016-10...
  • Page 54 NOTE! The stimulation is deactivated below 10 rpm for safety reasons. For information about settings and feedback screens see chapter 5.6.3: „RehaMove Arm and Leg Training - Integrated Operation (FES 3-Interface) - Constant Stimulation" Version 2.4 / 2016-10 HASOMED GmbH...
  • Page 55: Templates For Common Muscle Combinations In Leg Training

    5.6.5.2 Unilateral stimulation: right leg Leg right 2 Channels Leg right 3 Channels Leg right 4 Channels 5.6.5.3 Bilateral stimulation of legs Leg bilateral 4 Channels Leg bilateral 6 Channels Leg bilateral 8 Channels HASOMED GmbH Version 2.4 / 2016-10...
  • Page 56: Templates For Common Muscle Combinations In Arm Training

    Arm left 2 Channels Arm left 4 Channels 5.6.6.2 Unilateral stimulation: right arm Arm right 2 Channels Arm right 4 Channels 5.6.6.3 Bilateral stimulatation of arms Arm bilateral 4 Channels Arm bilateral 8 Channels Version 2.4 / 2016-10 HASOMED GmbH...
  • Page 57: Details About The Feedback Screens

    There are five different active power levels/intensity levels. Speed/ rpm In the center of the graphic the current speed in rpm is shown. The speed display is updated every two seconds. HASOMED GmbH Version 2.4 / 2016-10...
  • Page 58 The user is "active" if the current speed is at least 2rpm faster than the set passive speed. 2. Active performance of the user is specified in watt (W). 3. Average active performance results from the Version 2.4 / 2016-10 HASOMED GmbH...
  • Page 59: Access Training History After Session Is Finished

    Time: the stimulation time Intensity: the stimulation intensity Distance: the active distance Power: the power created Use buttons: Table: For an overview about the progression of each stimulation parameter Exit: Go back to the start window HASOMED GmbH Version 2.4 / 2016-10...
  • Page 60 The number of the therapy session The date The start time The stimulation time The average pulse width during the session The frequency Use button: Results: To see further parameters (not included in FES2) The active training time Version 2.4 / 2016-10 HASOMED GmbH...
  • Page 61: Access Training History

    7 profiles, the one displayed in the white field is profile 1. Use buttons: Press Advanced: to see advanced options and Access Training history data of the selected profile Back: Go back to the window "Choose user" HASOMED GmbH Version 2.4 / 2016-10...
  • Page 62 Button is greyed out if there are no training history data available, i.e. if the profile has not been used before. History: graphic display Continue as described in chapter Access Training History after Session is finished Version 2.4 / 2016-10 HASOMED GmbH...
  • Page 63: Finishing A Stimulation Session

    Confirm “Read USB flash drive“ in the menu. Data are compared with the data base of the PC while reading the USB flash drive. Data are synchronized at once. If the therapy parameters have been modified on the stimulator or on the PC, a message is displayed HASOMED GmbH Version 2.4 / 2016-10...
  • Page 64 All further activities to check training parameters and to analyze history data refer to this user and profile. Version 2.4 / 2016-10 HASOMED GmbH...
  • Page 65 Activate the menu item “History data“ to see the data of the chosen user and profile. 5.6.11.4.2 Table The table demonstrates the chosen user including user’s profile, training parameters and - if available - the history data saved after each therapy session. The table can be HASOMED GmbH Version 2.4 / 2016-10...
  • Page 66 Up to four single graphics positioned on top of each other can be shown in a general survey. These graphics are time based. Please note that each graphic documents data with the same measurement unit. Version 2.4 / 2016-10 HASOMED GmbH...
  • Page 67: Rehamove Letto2

    It can also be effectively applied in home care. Ask the manufacturer Hasomed for a RehaMove Letto2 license. The RehaMove Letto2 menu navigation corresponds to the settings of the RehaMove leg training.
  • Page 68: Part 6 General Stimulation/ Sequence Mode

    Check that the supply voltage of the unit matches with your main current. Only connect the RehaMove2 with the main outlet if the values match. If they do not match or damages to the power supply occur, please contact the manufacturer HASOMED GmbH.
  • Page 69: Create New Users And New Profiles

    General Stimulation/ Sequence Mode Use only properly earthed power outlets. Use only the original power supply delivered by the manufacturer HASOMED GmbH. If an electric cable has been damaged, stop session immediately and contact the manufacturer. Connect cables in a way that no person walking by could get caught in the cables and these can not be damaged.
  • Page 70 BF_R: 55 - 100% = 3.3 - 6 Sek An overview of standard values can be found in chapter "Electrode Placement for common muscle Combinations for Sequence Mode" Start and stop percentages can be changed by the user. Version 2.4 / 2016-10 HASOMED GmbH...
  • Page 71 Define parameters: Frequency The frequency indicates the number of impulses per second. Press the button Frequency in order to change the frequency. A field above the turning knob pops up with the present value. HASOMED GmbH Version 2.4 / 2016-10...
  • Page 72 If the stimulation is active, the status indication line is coloured in yellow. Use the turning knob: In order to change current, turn the knob In order to confirm entries, press the turning knob Next: Test current for further channels if activated. Version 2.4 / 2016-10 HASOMED GmbH...
  • Page 73: Operation

    Start: to start each single sequence Exit: Cancel the stimulation For settings of pulse width, frequency, current and interval please see the following chapters: RehaMove Arm and Leg Training - integrated operation (FES 3 interface) "Constant Stimulation Training". HASOMED GmbH Version 2.4 / 2016-10...
  • Page 74: Templates For Common Muscle Combinations In Sequence Mode

    M. Flexor 0-1.8 0-46 Extension_2Ch L/R flex and digitorum extend finger M. Extensor 2.2-4.0 54-100 of left or right digitorum hand Shoulder simultaneousl M. Deltoid 0-4.0 0-100 stabilisation_2Ch L/ y contract anterior left or right Version 2.4 / 2016-10 HASOMED GmbH...
  • Page 75 0-46 Extension_4Ch flex and digitorum extend finger M. Extensor 2.2-4.0 54-100 of left and digitorum right hand Shoulder_Stabilisati simultaneousl M. Deltoid 0-4.0 0-100 on_4Ch y flex anterior left and right 0-4.0 0-100 shoulder Supraspinatu HASOMED GmbH Version 2.4 / 2016-10...
  • Page 76: Legs

    Plantarflect._2Ch extend and Anterior plantarflex foot of right or M. Gastrocnemius 2.2-4.0 54-100 left leg Pressure contraction M. Gluteus 0-4.0 0-100 sore_prevention_ of gluteal 1Ch L/R muscles Bilateral: for right and left leg simultaneously Version 2.4 / 2016-10 HASOMED GmbH...
  • Page 77 BF_R 0-40 extension left M. Iliopsoas IO_R 0-40 Crawling_8Ch hip and M. Quadriceps QU_R 50-90 knee flexion M. Gluteus GL_R 50-90 left and M. Biceps femoris BF_L 50-90 extension right, M. Iliopsoas IO_L 50-90 HASOMED GmbH Version 2.4 / 2016-10...
  • Page 78: Torso

    M. Rhomboideus 0-4.0 0-100 major M. Serratus 0-4.0 0-100 anterior Lateral lateral M. Obliquus 0-4.0 0-100 inclination_3Ch inclination externus abdominis M. Pectoralis major PM 0-4.0 0-100 M. Serratus 0-4.0 0-100 anterior Version 2.4 / 2016-10 HASOMED GmbH...
  • Page 79 0-4.0 0-100 LS_Extension_6C extend M. Trapezius 0-4.0 0-100 lumbar M. Erector spina 0-4.0 0-100 spine M. Latissimus 0-4.0 0-100 dorsi flex W. Rectus 0-4.0 0-100 LS_Flection_8Ch thoracic/ abdominis lumbar M. Obliquus 0-4.0 0-100 spine HASOMED GmbH Version 2.4 / 2016-10...
  • Page 80 0-4.0 0-100 maximus TS/LS_Flection/ alternatingl W. Rectus 0-1.8 0-46 Extension_8Ch y flex and abdominis extend M. Pectoralis major PM 0-1.8 0-46 thoracic M. Erector spina 2.2-4.0 54-100 and lumbar spine M. Trapezius 2.2-4.0 54-100 Version 2.4 / 2016-10 HASOMED GmbH...
  • Page 81: Stepping

    M. Gastrocnemius 10-50 Step_Leg_6C step with lower M. Quadriceps femoris 40-65 and upper leg M. Biceps femoris 30-63 activation in M. Gluteus 65-20 left leg Step_Leg_6C step with lower 6 M. Quadriceps femoris 90-15 HASOMED GmbH Version 2.4 / 2016-10...
  • Page 82 30-63 leg activation in both legs M. Quadriceps femoris QU_R 90-15 M. Biceps femoris BF_R 80-13 M. Tibialis Anterior TA_L 5-62 M. Gastrocnemius GA_L 60-100 M. Tibialis Anterior TA_R 55-12 M. Gastrocnemius GA_R 10-50 Version 2.4 / 2016-10 HASOMED GmbH...
  • Page 83: External Trigger

    In order to select a triggering type, turn the knob In order to confirm entries, press the Next Regarding further steps during creation of a new user program, refer to chapter "Create a new User Program". Please note! HASOMED GmbH Version 2.4 / 2016-10...
  • Page 84 "Choose trigger" you are able to choose the trigger type. Use the turning knob: In order to change selection, turn the knob In order to confirm entries, press the turning knob Version 2.4 / 2016-10 HASOMED GmbH...
  • Page 85: Adjusting The External Double Trigger

    These templates show selected channels from the front side and back side. Use the turning knob in order to select one template. Press Next to confirm your entries. HASOMED GmbH Version 2.4 / 2016-10...
  • Page 86: Edit Or Delete A User Profile, Show Training History

    Please follow the instructions in chapters "Edit or delete a User Profile" and "Show Training History" in analogy. Finishing a Stimulation Session 1. Stop stimulation, switch off stimulator 2. Disconnect electrodes from cables and detach from the skin Version 2.4 / 2016-10 HASOMED GmbH...
  • Page 87: Part 7 Fault Indication

    Electrode error! During the session the Check whether the electrodes are electrodes are properly constantly checked. If attached and the electrodes or connected. Press Next. electrode cables are not properly connected, this window comes up. HASOMED GmbH Version 2.4 / 2016-10...
  • Page 88 Check the cable from error! MOTOmed is checked the RehaStim2 to the Training was finished. before the session motion trainer and starts. This window make sure that it is pops up if connected properly. Version 2.4 / 2016-10 HASOMED GmbH...
  • Page 89 This note is displayed if Release the quick stop the current output button to activate the should be higher than current output. 0mA and the quick stop is pressed. In this case there is no current output. HASOMED GmbH Version 2.4 / 2016-10...
  • Page 90: Part 8 Declaration Of Warranty

    Operation Manual RehaStim2, RehaMove2 Declaration of Warranty HASOMED GmbH gives a warranty on the function of the equipment, with the extent according to above description for 2 years after distribution within the European Union. for 1 year after distribution in countries outside of the European Union.
  • Page 91: Part 9 Address Of Manufacturer

    Address of Manufacturer Address of Manufacturer Developer and manufacturer: HASOMED GmbH Paul- Ecke- Str. 1 39114 Magdeburg Germany Managing Directors: Dr. Peter Weber, Matthias Weber Phone: +49 (0) 391 62 30 112 Email: info@hasomed.com Service address: HASOMED GmbH Paul-Ecke-Str. 1...

This manual is also suitable for:

Rehamove 2

Table of Contents

Save PDF