I have a geek pure booster pump for my to unit. I can find the flow diagrams for installation, but I can find detailed instructions showing which openings on the transformer, pressure sensor,etc the tubes from the r /o filters connect to .p!ease, send to my email the detailed instructions or direct me to sight on internet Thank you
Summary of Contents for Geekpure RO4
Page 1
Portable Reverse Osmosis Water Filtration System Installation and Maintenance Manual Geekpure FILTER CARTRIDGE CONFIGURATION MAY BE SUBJECT TO CHANGE. INSTALLERS: 1.PLEASE READ ALL INSTRUCTIONS BEFORE INSTALLING AND USING THIS SYSTEM. 2.IT IS RECOMMENDED TO WAIT UNTIL THE ENTIRE SYSTEM IS PRESSURIZED AND RE-CHECK FOR ANY LEAKS BEFORE LEAVING INSTALLATION SITE.
Table of Contents How Your System Works................Technical Data of Membrane................ Before You Start.................... Tools Needed ....................System Location ..................Parts of the System ..................Installation Steps ..................Installing the Filters ..................Installing Tank Ball Valve ................Installing the Faucet ................. 9-10 Installing the Feed Water Diverter Valve............
How Your System Works Geekpure RO4 Series system uses four stages of treatment to filter your water: Stage 1 - Remove sand, dirt, sediment Stage 2 - Remove chlorine, taste & odors, very fine particulates Stage 3 - Reduce total dissolved minerals...
Concentration — 250ppm NaCl Pressure — 60psig Temperature — 77°F (25°C) Recovery —15% pH Range — 6.5 ~ 7.0 Note:Due to different temperature, different water pressure and feed water quality, the product water capacity and pure water quality (TDS) is different. That is the reason why we feel lower pure water capacity in the winter, but higher in the summer.
Do not use for the treatment of water that is visually contaminated(cloudy) or has an obvious contamination source, such as contamination by raw sewage. All plumbing should be done in accordance with local codes and requirements. Non-Booster pump models work on inlet water pressures of 40 psi (minimum) to 100 psi (maximum).If your house water pressure is over the maximum, install a pressure reducing valve in the water supply line to the filter system.
Tank Tank ball valve Water Pipe RO Membrane Clip Feed Water Diverter Valve Drain Clamp Mounting Clamp Manual System Location Your RO system may be installed under the sink, in a basement, or other location depending on available space. It is recommended the system be installed in as close a proximity to the faucet to ensure optimal system flow rate.
Page 7
Guidelines for component placement are as follows: Faucet should be placed near the sink where drinking/cooking water is normally required. A 2" flat surface is required to mount the faucet if an existing hole for a second faucet is not available.The thickness of the mounting surface should not exceed 1-1/4"...
Parts of the System Faucet 3/8" White Tube Drain Feed Water Pressure Tank Figure 2. Typical Installation The following components make up your Reverse Osmosis Drinking Water System: 1. PP Sediment removes larger particles such as sand, silt, and rust. 2.
4. Post-Carbon Filter is provided for a final "polish" to provide great tasting drinking water. 5. Storage Tank (2.8 Gal) holds filtered water, ready for use. 6. Feed Water Diverter Valve is connected to the cold water line to supply water to the RO system.
1 Remove the tube from the fitting and twist off the housing cap with wrench Push the new membrane into housing 3 Put the housing cap back and tighten it. you should pull out old membrane before step 2 when you replace new membrane.(you may use pliers if necessary.) NOTE:Please ensure the RO System to work for about 30 minutes before drinking the purified water for washing...
NOTES: While there is a gasket that seals against the shut off valve, it is rec- ommended to still use teflon tape on the tank threads to insure a good seal is achieved. It is also recommended to check for any leaks after the system has had time to produce water and pressurize inside the storage tank.
Page 12
Porcelain, Enamel, Ceramic on Metal or Cast Iron Sinks For porcelain/enamel sinks marble or granite counter tops refer to manufacturer/Supplier for proper drilling instructions. Installation procedures for stainless steel sinks Recommended tools: ·Center punch · Variable speed drill ·High speed drill bits ·Protective gloves &...
Installing the Feed Water Diverter Valve The feed water diverter Valve is designed for use with 3/8 t o 1/2” ” OD soft copper supply tubing. Turn off cold water valve from under sink or main water line valve for whole house. Wrap threads of Feed Water Diverter Valve with teflon tape.
Never install a waste water saddle close to the outlet of a garbage disposal or plugging of the RO drain line may result . Refer to location in Figure 3. 1. Position half of the saddle with quick connect fitting at selected location and mark for the opening.
1. Locate the unit in the desired position. Make sure it is at least 3" off the floor. Level it and mark the location of mounting screws. 2. Install the screws. Leave 1/4" of the screw head out from the wall.
Page 16
Installation tips for tube and quick connect fittings Figure 4 Figure 5 Figure 6 To connect: See Figure 4 and 5. Check and cut the tubing end squarely and cleanly with utility knife or scissors. Make a 5/8”mark at the end of the tube so you will be able to confirm when the tube is inserted fully into the fitting.
To disconnect: See Figures 6. Remove the blue lock clip from the fitting. With the blue lock clip removed, use your thumb and index finger to hold down the lock sleeve. This will release the metal teeth holding the tube in place. While holding the lock sleeve down with that hand, use your other hand to remove the tube from the fitting.
With all components in place, complete final tubing connections using these guidelines: · Tubing should follow contour of the cabinets · Cut tubing to desired length using square cuts and proper cutting device · Make no sharp bends · keep tubing from the post-filter to the faucet as short as practical for good flow.
Flush System and Check Operation Start-up 1. Check all connections to be sure they are secure. 2. Turn on feed water valve and check for leaks. (turn off and correct leaks if leaks occur). 3. Close faucet and wait 5 minutes to see if leaks result. (turn off and correct leaks if leaks occur).
Change Membrane Procedure 1. Turn off water supply by turning handle on feed water diverter valve clockwise until valve is fully closed. 2.Turn storage tank valve clockwise to close. 3.Open faucet to relieve pressure. 4.Remove quick connect fittings from R/O Membrane. 5.Insert RO element into housing with the small double o rings facing inward.
Page 21
UPC code Description Item No Comments PP sediment filter T33-PP The 1st stage Coconut carbon T33-CARBON The 2nd stage ASIN. B08QZ5WZDH Reverse osmosis membrane GP-TW-1812-100G The 3rd stage,NSF certificated Post inline carbon RO5-COC10 The 4th stage 680577668331 Membrane housing RO5-ROH 680577669062 Check valve DC-020Y...
Trouble Shooting PROBLEM CAUSE SOLUTION 1. Water supply is turned 1. Turn on feed water 2.Add Booster pump kit. you 2.Inlet water pressure less than can buy it (ASIN B07KHV93S5) 40 psi via Amazon 3.Replace new filters if you use it 1 year.
The Life Time of the Filter Cartridges Depends on Usage Amount and Feed Water Quality,and most of filters life time is about 1 year or less.So,Geekpure Ro replacement filters set is warrant- ed to be free from defects in materials and workmanship under normal use within the operation specifications for a period of 1 year warranty from the date of original purchase.
Need help?
Do you have a question about the RO4 and is the answer not in the manual?
Questions and answers
I have a geek pure booster pump for my to unit. I can find the flow diagrams for installation, but I can find detailed instructions showing which openings on the transformer, pressure sensor,etc the tubes from the r /o filters connect to .p!ease, send to my email the detailed instructions or direct me to sight on internet Thank you