Summary of Contents for Spencer FL-X W
Page 1
Flowmeter Mode d’emploi Débitmètres Instrucciones de uso Flujómetros Instruções de utilização Debitómetros Használati utasítás Áramlásmérők Инструкции за употреба Дебитомери Instrucțiuni de utilizare Debitmetre SPENCER ITALIA SRL SPENCER ITALIA SRL – Via Provinciale n° 12 43038 Sala Baganza (PR) – Italy...
Page 2
INDICE / CONTENTS / INHALTSVERZEICHNIS / SOMMAIRE 1. MODELLI 11.3 PERIODIC OVERHAUL 2. DESTINAZIONE D’USO 11.4 SPECIAL MAINTENANCE 2.1 DESTINAZIONE D’USO E BENEFICI CLINICI 11.5 LIFE SPAN 2.2 PAZIENTI DESTINATARI 12. TROUBLESHOOTING TABLE 13. ACCESSORIES 2.3 CRITERI DI SELEZIONE PAZIENTI 2.4 CONTROINDICAZIONI ED EFFETTI COLLATERALI 14.
REFERENCE STANDARDS As Distributor or End-User of the products manufactured and/or marketed by Spencer Italia S.r.l., users are strictly required to be familiar with the legal provisions in force in the country of destination of the goods, applicable to the devices to be supplied (including regulations relating to technical specifications and/or safety requirements) and, therefore, to understand the requirements necessary to ensure compliance of the products themselves with all legal requirements of the territory.
EU Regulation 2017/745 requires manufacturers and distributors of medical devices to keep track of their location. If the device is in a location other than the address to which it was shipped or sold, or if it was donated, lost, stolen, exported or destroyed, permanently removed from use, or if the device was not delivered directly from Spencer Italia S.r.l., please register the device at http://service.spencer.it, or inform Customer Service (see §...
No residual risks, or rather risks that could arise despite compliance with all warnings in this user manual, have been identified. TECHNICAL DATA AND COMPONENTS Note: Spencer Italia S.r.l. reserves the right to make changes to specifications without notice. FL-K...
FL-X DESCRIPTION AND MATERIAL Reading column Adjustment knob Ruotando la manopola di regolazione, una sfera all’interno della Made of aluminum, it allows flow regulation colonnina in policarbonato, indica il valore istantaneo di flusso Humidifier patient connection port Humidifier container Aluminum hose connector applied to the humidifier, to which a hose Polycarbonate container to be filled with distilled water intended for conforming to ISO 13544-2 is connected.
To screw the humidifier to the flow meter, screw them together, keeping the grip firmly to avoid accidental falls that could damage the devices. On the humidifier canister, there are the markings of the maximum and minimum water levels. When the device is put into service, it will be necessary to unscrew the jar from the cap, fill it with distilled water up to the level indicated with MAX, then screw again the canister.
The device, if used as described in the following instructions, has an average life span of 2 years from the date of purchase. Spencer Italia S.r.l. will accept no responsibility for incorrect operation or damage caused by the use of devices that have exceeded the maximum allowable life span.
Page 10
Código CCI5332 Első kiadás: 2022/06/20 Fel. 1 2022/06/20 Kód CCI5332 Първо издание: 20/06/2022 г. Ред. 1 20/06/2022 г. Код CCI5332 Prima ediție 20/06/2022 Rev. 1 20/06/2022 CCI5332 spencer.it support.spencer.it - e-mail: info@spencer.it | service: service@spencer.it Ph./Tel. +39.0521.541111 Quality System EN ISO 9001 – EN ISO 13485...