Advertisement

Quick Links

NON-CONTRACTUAL PICTURES | DOC. VERSION 08072021
MASTER ONE
TECHNICAL DOCUMENTATION
Opening the charging station and any changes to the configuration must be done by a qualified electrician and must comply with local
regulations and laws for safety in the use of electricity. Failure to comply with the regulations in this manual will result in the end the
warranty period.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MASTER ONE and is the answer not in the manual?

Questions and answers

Summary of Contents for Green motion MASTER ONE

  • Page 1 NON-CONTRACTUAL PICTURES | DOC. VERSION 08072021 MASTER ONE TECHNICAL DOCUMENTATION Opening the charging station and any changes to the configuration must be done by a qualified electrician and must comply with local regulations and laws for safety in the use of electricity. Failure to comply with the regulations in this manual will result in the end the...
  • Page 2: Table Of Contents

    CONTENT INTRODUCTION Technical Specifications Dimensions and weights INSTALLATION Mounting Electrical connection Connection to the LAN network Internet connection RS485 and CAN connection Connection of the MASTER ONE with the Green Motion PRIVATE ONE Support ANNEXES MASTER ONE housing dimensions (mm)
  • Page 3: Introduction

    MASTER ONE – TECHNICAL DOCUMENTATION Page 3 1 INTRODUCTION Technical Specifications POWER INPUT SMART POWER MANAGEMENT SYSTEM Input voltage 1 x 230 VAC 50 Hz Input current 1 x 8 Arms Standby-consumption <30 W CHARGING STATIONS CONTROL Types Slow-charge stations as well as multi-standard Combo and CHAdeMO quick-...
  • Page 4: Dimensions And Weights

    MASTER ONE – TECHNICAL DOCUMENTATION Page 4 Dimensions and weights Width 350 mm Height 588 mm Depth 112 mm Column height 1010 mm Total height 1580 mm Station Weight 10 Kg Column Weight 30 Kg max 2 INSTALLATION Mounting 2.1.1 Mounting on the column (optional) Fixing the column with 4 x M8 stainless steel threaded rods on a 350 x 350 mm (minimum) concrete base.
  • Page 5 MASTER ONE – TECHNICAL DOCUMENTATION Page 5 The MASTER ONE should be fixed on the column with 2 x M8 stainless steel screws. Screw through the charging station (do not forget the flat washers). 155mm Ø 25 mm 1100mm 2.1.2 Mounting on the wall Fixing the MASTER ONE to the wall with 2 screws Ø6 mm, 170mm apart.
  • Page 6: Electrical Connection

    The network cable can be introduced above or below the MASTER ONE and it should be connected onto the RJ45 socket, which is located under the screen. If the MASTER ONE is equipped with the contactless payment module the RJ45 socket is located on the switch.
  • Page 7 MASTER ONE – TECHNICAL DOCUMENTATION Page 7 Green Motion charging stations communicate with the Green Motion server at: Description Internet Address (FQDN) IP Address Port No. Green Motion SA Server 108.129.36.195 Green Motion SA Service Update fw.greenmotion.ch Green Motion SA Service Update fw.greenmotion.ch...
  • Page 8: Rs485 And Can Connection

    The termination resistance can be activated on the MASTER ONE by putting a plug on the “JMP2” which is located under the screen (if it is located at one end of the BUS). The termination resistance can be activated on the MASTER ONE by putting a plug on “J15” and on...
  • Page 9: Connection Of The Master One With The Green Motion Private One

    Connection of the MASTER ONE with the Green Motion PRIVATE ONE charging stations The connection between the MASTER ONE and the PRIVATE ONE charging stations is made via a CAN bus by a twisted pair cable (DATA Dca-flex C 2x2x0.75).
  • Page 10 MASTER ONE – TECHNICAL DOCUMENTATION Page 10 On the PRIVATE ONE charging station, the CAN bus cable is connected onto the terminals 17 (CAN+) and 18 (CAN-): This schema may vary according to the controlled P1 charging station. There must be a shielded twisted pair cable (e.g.
  • Page 11: Support

    The termination resistance can be activated by activating the upper DIPSwitch number 2: Deactivated Activated: On the MASTER ONE, the CAN bus cables is connected onto the terminals CAN- and CAN+: Support Green Motion telephone support is available Monday to Friday from 08:00 to 12:00 and from 13:00 to 17:00 (16:00 on Friday) CET Email : support@greenmotion.ch...
  • Page 12: Annexes 123

    MASTER ONE – TECHNICAL DOCUMENTATION Page 12 3 ANNEXES MASTER ONE housing dimensions (mm)
  • Page 13 MASTER ONE – TECHNICAL DOCUMENTATION Page 13 Green Motion Ltd Chemin de Maillefer 61 1052 Le Mont-sur-Lausanne Switzerland GreenMotionEV.com info@greenmotion.ch +41 (0)21 544 04 44...

Table of Contents