  • Page 1 SERVICE BULLETIN SB3021 Rev. H 10/08 ® P-SET ELECTRONIC PRESET CONTROL HANDLE Model 3331-014 (with Semi-Automatic Tip) Model 3331-020 (with Flex Extension & Semi-Automatic Tip) Model 3331-012 (Bare) Thoroughly read and understand this manual before installing, operating or servicing this equipment.
  • Page 2: General Safety

    If you require yourself and others. 3) Open dispensing valve until further assistance please contact your local pressure is relieved. Balcrank distributor or Balcrank authorized ® ® service center. WARNING A manual tip cannot be used on P-Set control handle.
  • Page 3: Specifications

    Specifications Accuracy: + - 0.5% (of Reading) Flow Range: 0.26 – 8 gal/min Maximum Operating Pressure: 1,500 PSI Weight: 2.55 lbs Inlet: ½” NPT Outlet: 3/8” NPT (prior to 6/03) 3/8” NPS (after 6/03) Operating Temperature: – 122 Wetted Parts: Aluminium, Acetal, Steel, Nitrile Rubber Fluid Compatibility: Engine Oil, Diesel Oil, Automatic Transmission Fluid,...
  • Page 4: Options Settings

    Operation of Buttons Changing Units The control buttons can be used in two ways Press and hold the reset button until “units” appears. Press: Press & release the button. Press the reset button to cycle through the units of Double click: Press & release the button twice measure.
  • Page 5: Maintenance

    Handle Disassembly Pressing cal cycles through options Use a clean work area to carry out maintenance. Pressing reset cycles through values for each option A) Remove the fluid hose from the control handle Pressing and holding reset 5 seconds saves the set- inlet swivel (31).
  • Page 6: Field Calibration

    Meter Reassembly Field Calibration A) Clean and inspect all parts. Replace any suspect, Field calibration allows a +_5% adjustment of worn, or damaged components. the calibration. B) Replace rotors (13). In Options mode press cal 5 seconds. Current Note: Ensure the rotor with the magnets is field calibration factor will be displayed 95-105 assembled with the magnets facing up and To reset the factor to 100...
  • Page 7 P-Set Electronic Preset Control Handle Parts List Item Part No. Qty. In Kit Description Item Part No. Qty. In Kit Description 830727 Boot, P-Set Latch Plate Assembly 830726 Module, P-Set Latch Pivot Pin Screws Spring Latch Release Assembly Plunger Battery Cover Screw Seal O-Ring Valve Body...
  • Page 8 All Balcrank equipment sold by authorized Balcrank distributors is warranted to their original customer to be free from defects in materials and workmanship for a period of one year from the date of sale to that customer. Selected Balcrank equipment carries warranty terms for a more extended period as defined in the Balcrank Lubrication Equipment &...