Balcrank PGE-55 Operation, Installation, Maintenance And Repair Manual

Balcrank PGE-55 Operation, Installation, Maintenance And Repair Manual

Electronic control handle

Advertisement

Quick Links

PGE-55 ELECTRONIC
CONTROL HANDLE
Thoroughly read and understand this manual before
installing, operating or servicing this equipment.
OPERATION, INSTALLATION,
MAINTENANCE AND REPAIR GUIDE
SERVICE BULLETIN SB 3026
Rev. D 11/09
Model #3330-054
3330-055
3330-056
3330-057
3330-058
3330-059

Advertisement

Table of Contents
loading

Summary of Contents for Balcrank PGE-55

  • Page 1 SERVICE BULLETIN SB 3026 Rev. D 11/09 PGE-55 ELECTRONIC CONTROL HANDLE Model #3330-054 3330-055 3330-056 3330-057 3330-058 3330-059 Thoroughly read and understand this manual before installing, operating or servicing this equipment. OPERATION, INSTALLATION, MAINTENANCE AND REPAIR GUIDE...
  • Page 2: General Safety Requirements

    Refer to the “trouble shooting guide” or death. return unit to your nearest Balcrank authorized service center. • Never allow any part of the human body to come in contact with the control handle outlet.
  • Page 3: General Description

    GENERAL DESCRIPTION This manual assists you in operating and maintaining your new PGE-55 Electronic Control Handle. The information contained will help you ensure many years of dependable performance and trouble free operation. Please take a few moments to read through this manual before installing and operating your new control handle.
  • Page 4 METER INTRODUCTION 4) To store the selected units, press and hold down the Reset button for five seconds Operating mode description. until the batch and accumulative totals appear. If the reset button is not held down Sleep Mode: To minimize battery consumption for 5 seconds, the original settings will be the meter will revert to sleep mode if left idle stored.
  • Page 5: Maintenance

    NOTE: The cutout section in the middle of WARNING the valve cam (16) must face the inlet swivel (31). Before maintenance or repair, shut off the compressed air line, bleed C) Replace the valve cam (16) into the body the pressure, and disconnect the (15).
  • Page 6 Meter Reassembly PGE-55 Parts List A) Clean and inspect all parts. Replace any ITEM PART NO. QTY. IN KIT DESCRIPTION suspect, worn, or damaged components. 830727 Boot B) Replace rotors (13). 831251 Electronic Module NOTE: Ensure the rotor with the magnets is...
  • Page 7 PGE-55 Electronic Control Handle Parts Diagram t r i f I ( t r i t r i (Item 37)
  • Page 8 All Balcrank equipment sold by authorized Balcrank distributors is warranted to their original customer to be free from defects in materials and workmanship for a period of one year from the date of sale to that customer. Selected Balcrank equipment carries warranty terms for a more extended period as defined in the Balcrank Lubrication Equipment &...

This manual is also suitable for:

3330-0543330-0553330-0563330-0573330-0583330-059

Table of Contents