Anoxia is a treatment that removes oxygen from a
controlled environment. It is a safe and universal
treatment against insects of any kind that does not
damage nor alter treated objects.
Samitech Smart Anoxia is easy to use and allows remote
and real time control of the treatment's evolution thus
avoiding displacements.
19/10/2022

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Smart Anoxia and is the answer not in the manual?

Questions and answers

Summary of Contents for SAMITECH Smart Anoxia

  • Page 1 It is a safe and universal treatment against insects of any kind that does not damage nor alter treated objects. Samitech Smart Anoxia is easy to use and allows remote and real time control of the treatment’s evolution thus avoiding displacements.
  • Page 2: Table Of Contents

    WiFi connection Setup ........................11 Control Panel ............................13 Registering a control unit ........................14 Treatment duration ..........................14 Precautions during treatment ....................... 15 How to open the treatment bubble ...................... 15 Safety Instructions ..........................15 MANUAL SMART ANOXIA EN.DOCX 19/10/2022...
  • Page 3: Introduction

    The Smart Anoxia system does not use gases such as Nitrogen or Carbon Dioxide. The treatment is carried out by completely removing the Oxygen contained in the treatment bubble.
  • Page 4: Product Description

    China, North Korea, Iran and several countries in underdeveloped Africa. The data service is intended only to serve Smart Anoxia devices and cannot be used for Internet access of other types of mobile devices or computers. Any unauthorized use, modification of the router configuration or removal of the SIM card included, will result in the definitive interruption of the data service and loss of the warranty.
  • Page 5: Oxygen Absorbers

    The Starter Pack includes a 30cm long clamp thermal sealer to facilitate the heat sealing of the treatment bubble. Oxygen absorbers The Smart Anoxia system uses oxygen absorbers to fully consume the oxygen contained in the treatment bubble. Insert the recommended dose of absorbers into the treatment bubble (see dosage detail).
  • Page 6: The Treatment Bubble

    Remember to have the control unit's battery fully charged to ensure you can complete the treatment without the battery running out. Try to foster free air circulation inside the bubble. Leave any type of container, drawer, door or packaging open to avoid air bags that will slow down treatment. MANUAL SMART ANOXIA EN.DOCX 19/10/2022...
  • Page 7: Using The Heat Sealer

    The following indications describe recommended procedure for general use. Practice and experience will allow you to define your own method. Prepare the bubble base with Deposit objects on top of the Wrap the objects with the film polybarrier film film MANUAL SMART ANOXIA EN.DOCX 19/10/2022...
  • Page 8: Detailed Mounting Guide

    It is not necessary to create vacuum, just remove excess air to save oxygen absorbers. Be careful with objects that may come into contact with the film and damage it when emptying excess air. MANUAL SMART ANOXIA EN.DOCX 19/10/2022...
  • Page 9: Use Of Oxygen Absorbers And Humidity Control

    The dosage of oxygen absorbers should be carried out based on this calculation of the volume of air contained in the bubble. Dosage La proporción recomendada para un tratamiento estándar es la siguiente: MANUAL SMART ANOXIA EN.DOCX 19/10/2022...
  • Page 10: Using The Control Unit

    Using the control unit The control unit is an electronic device that collects information captured inside the treatment bubble and sends it wirelessly to the cloud. ON/OFF switch Battery charger port Configuration button MANUAL SMART ANOXIA EN.DOCX 19/10/2022...
  • Page 11: Battery Charging

    The control unit connects by default to the IoT router supplied in the Starter Pack. If you haven't purchased a router or want to use another network, you can configure your control unit to connect to any other standard 2.4GHz WiFi network. MANUAL SMART ANOXIA EN.DOCX 19/10/2022...
  • Page 12 Release the setup button now. At this point, your control unit is in configuration mode. Search your mobile terminal for the WiFi network called “Smart Anoxia Setup”. Connect to this network. No password needed.
  • Page 13: Control Panel

    Device battery status WiFi signal quality Last connection If you have more than one device, you can manage them and select the device you want to monitor to view the details of each running treatment. MANUAL SMART ANOXIA EN.DOCX 19/10/2022...
  • Page 14: Registering A Control Unit

    You will need a mobile terminal that can read QR codes. Nowadays most smartphone can do it. At the bottom of your new Smart Anoxia device is a label that includes a QR code. Open the camera on your mobile phone or your QR code reading app and access the address obtained to register your unit.
  • Page 15: Precautions During Treatment

    Safety Instructions Smart Anoxia is a safe product. Use this device only as described in this manual. The operator assumes all responsibility for the improper use of the equipment. Avoid blows due to falls from the control unit. Keep the control unit always protected in its protective case when not in use.
  • Page 16 Do not leave equipment within reach of children or babies. Elements such as polybarrier film could cause suffocation. Anoxia treatments are indicated for pest control. Do not use an anoxia treatment against other types of living beings. MANUAL SMART ANOXIA EN.DOCX 19/10/2022...