Revision date : 04/03/2009
CONTENTS
OPTIONAL STS-NET ADAPTOR FOR ETHERNET
MD-NET installation kit contents
OPTIONAL RS232 DUPLEXER
RS232 Duplexer block connection
Front view of the RS232-DUPLEXER
RS232-Duplexer connection diagram
The hardware of the comm ports
Pinout of the comm ports
Power supply connections of R232 DUPLEXER
RS232 Duplexer installation
STS Manager software setup
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ML200 and is the answer not in the manual?

Questions and answers

Summary of Contents for Tescom ML200

  • Page 1: Table Of Contents

    Revision date : 04/03/2009 CONTENTS OVERVIEW STS COMMUNICATION OPTIONAL STS-NET ADAPTOR FOR ETHERNET STS-NET adaptor block connection Front view of the STS-NET adaptor MD-NET installation kit contents TCP-IP Connection diagram The hardware of the device port and com1 port Pinout of the device port and com1 port Power supply connections of MD-NET adaptor STS-NET adaptor installation Possible TCP-IP connections...
  • Page 2: Overview

    OVERVIEW STS COMMUNICATION Standard STS devices contains one RS232 communication port .Maximum communication distance of the RS232 system is 15 meters but the communication speed effects the cable length. The selected RS232 baud rate on STS units is 2400 baud. This baud rate makes possible to use 50 meters communication cable.
  • Page 3: Sts-Net Adaptor Block Connection

    STS-NET adaptor block connection The local and remote connection is showned in the figure below,at the same time 2 data communication is supplied. 2 connections are interactive at the same time ,sending command to STS and getting data from STS is possible from 2 PC computers at the same time. Front view of the STS-NET adaptor STS port Local PC port...
  • Page 4: Tcp-Ip Connection Diagram

    TCP-IP Connection diagram STS serial port is connected to device port of the STS-NET adaptor with CC05 communication cable. The hardware of the device port and com1 port Baud rate 2400 Data 8 bits Stop bit Parity none Handshaking none Pinout of the device port and com1 port Com1 port pinout For PC connection on com1 port CC05 cable must be used.
  • Page 5: Power Supply Connections Of Md-Net Adaptor

    Power supply connections of MD-NET adaptor Before MD-NET installation ST232 board power supply connections • Disconnect the power connectors of the ST232 board (CN1 and CN2) • Connect the same cables to MD-NET adaptor CN1 and CN4 connectors and use new cable pair for CN1 and CN3 connectors to ST232 board After MD-NET installation power supply connections are modified as follows:...
  • Page 6: Sts-Net Adaptor Installation

    STS-NET adaptor installation STS-NET adaptor space is reserved on front back panel of the STS. The adaptor place is closed with metal part , before installation this metal must be removed. a) Shutdown (power off) the STS unit for installation. b) Open front panel of the STS c) Cut metal holders to open place for STS-NET adaptor.
  • Page 7: Possible Tcp-Ip Connections

    Currently adaptor is ready to use , see software section for setup. Possible TCP-IP connections a) Connecting STS-NET Ethernet port to network switch b) Connecting STS-NET to any PC Ethernet port directly Note : At direct PC connection the Ethernet connector pin configuration will be different refer to your network administrator.
  • Page 8: Tcp-Ip Network Setup Procedure

    TCP-IP Network setup procedure Before using TCP-IP adaptor some network setup required: - Install the Lantronix software from the ML200 CD - Launch installation (Start-Programs-Lantronix Device Installer) This utility program will locate all networks attached to the STS-NET Ethernet port.
  • Page 9 In the ASSIGN IP window select the STATIC IP option from the configuration window and then click the NEXT button. Note: If the new IP address is different from 10.0.0.xxx or if the subnet mask code is different from 255.0.0.0 the device connection may fail. In this case adapt the PC network settings to these values.
  • Page 10 After adapting the IP address of the STS-NET Ethernet port, the newly assigned IP address will appear in the device installation window. In order to configure the device it is necessary to connect to the port via Internet Protocol. Click on WEB CONFIGURATION in the installation program of the device. Then click GO to visualise the WEB PAGE.
  • Page 11 To configure the Ethernet port from the menu on the left, click CONNECTION to visualise the configuration page. Connect Mode Accept Incoming Active Connect None Connect Response None Local port 10001 Remote port 10001 Click OK to update the settings.
  • Page 12: Sts Manager Software Tcp-Ip Setup

    STS Manager software TCP-IP setup It is now possible to make the connection with the static switch via Ethernet. Launch the STS MANAGER program. In the SETTINGS window register the various IP addresses of the STSs to monitor, verify that the TCP/IP value is 10001 and then click SAVE to save the settings.