Flow Chart Of Troubleshooting - Samsung SCH-N500 Service Manual

Cdma telephone
Hide thumbs Also See for SCH-N500:
Table of Contents

Advertisement

7. Flow Chart of Troubleshooting

7-1 Logic Section
7-1-1 No Power
Press PWR button
Press PWR button
Yes
Yes
C240 + pin > 3.3volt?
C243 + pin > 3.3volt?
Yes
Yes
Q203 Pin1 "High" ?
Q203 Pin1 "High" ?
Yes
Yes
Q202 pin1,2,5,6 >=3.3volt?
Q202 pin1,2,5,6 >=3.3volt?
Yes
Yes
U204 VO2 =2.85volt
U204 VO2=2.85volt
VO3=2.65volt
&
VO1=2.8volt?
VO1=2.65volt ?
Yes
Yes
END
END
No
No
No
No
No
No
No
No
SAMSUNG Proprietary-Contents may change without notice
This Document can not be used without Samsung's authorization
Check Battery and its neighboring
Check Battery and its neighboring
circuits
circuits
( V_BAT Problem )
( V_BAT Problem )
Check U100,U204 and its neighboring
Check U100,U204 and its neighboring
circuits
circuits
( PS_HOLD Problem )
( PS_HOLD Problem )
Check Q202 and its neighboring
Check Q202 and its neighboring
( V_IN Problem )
( V_IN Problem )
Check U204 and its neighboring
Check U204 and its neighboring
( V_MSMP / V_MSMA Problem )
( V_MSMP / V_MSMA Problem )
7-1