Download Print this page

Parts List; Tools Required; Installation Instructions; Troubleshooting Guide - Sani-Lav 512FFL Operating Manual

6-person floor mount stainless steel wash station

Advertisement

C O L U M B I A S P E C I F I C AT I O N S

Parts List

(1) Floor mount wash station
(1) Leg assembly set
(18) Nuts, bolts and washers for leg assembly
(8) Washers and nuts for connection sink to leg assembly set
(6) 8" on center faucet
(6) Faucet mounting kit
(3) Strainer assembly with basket

Installation Instructions

Step 1
1. Assemble legs for the 54 and 56 series. For series 58, 510 and 512 the legs are pre-assembled.
2. Place wash station sink on the leg assembly. Secure legs to bowl with hardware provided.
3. Place wash station sink at the desired location.
4. Mark the floor where the mounting holes are at the base of the legs. See illustration A.
5. Drill holes as required for mounting hardware. Hardware not included.
Step 2
1. Install Faucet to the sink using faucet mounting kit provided. We recommend using pipe thread
sealant instead of Teflon tape.
2. Install strainer assembly to the drain hole.
3. Connect hot and cold water supply lines (not included) to the back of faucets.
Step 3
1. Position wash station sinks to pre-drilled holes and secure sink to the floor.
2. Connect waste line or drain pipe to the strainer assembly. Not included.
3. Connect water supply lines (Hot and Cold) to the water source. Not included.
4. Remove aerator from the spout and flush the water system.
5. Replace aerator to the spout.
6. Check for leaks and tighten connections if necessary.
Step 4
1. Seal gap between bowl and leg assembly as shown in illustration B.
2. When mounting against wall, it is recommended sealing the top of the backsplash to wall as
shown on illustration C.
Go to
columbiasinks.com
for more information on replacement parts and installation videos.
Trouble Shooting Guide
Problem
Possible Cause
Water drips
1. Seat washer is worn
from the spout
2. Seat is worn
or from under
3. O-rings are worn
the lever.
Notice for California Consumers
WARNING:
This product can expose you to chemicals including Chromium (hexavalent compounds),
Lead, and Phthalates (DEHP) which are known to the State of California to cause cancer and birth defects
or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
NOTE:
Lead content originates from Brass components in valves and faucets and is certified under
NSF/ANSI 372 as containing less than 0.25% lead in wetted surfaces.
To Diagnose
Remedy
Shut cold water source
Recommend
off. See if water still leaks
installing hot
from the spout. If leaks
or cold faucet
continues repair hot side
repair kit.
if not repair cold side.
F L O O R M O U N T WA S H S TAT I O N

Tools Required

Tape measure
Adjustable wrench
Drill motor and drill bits
Pipe wrench
Level
Safety glasses
Screw drivers: phillips and standard
Pencil
Socket wrench
800.626.2117
columbiasinks.com info@columbiasinks.com
2
Illustration A
Illustration B
Illustration C
©2021 Columbia Products

Advertisement

loading

This manual is also suitable for:

512ffl-0.5