S19314 Installation WARNING Flush the water supply lines before beginning installation and after installation is complete. Test the unit for leaks and adequate water flow. Main water supply to the eyewash should be “ON” at all times. Provisions shall be made to prevent unauthorized shutoff. CAUTION Emergency equipment must be supplied with tepid water (60°F to 100°F/15.6°C to 37.8°C).
S19314 Installation Halo Pre-Configured Models Intertek Halo Model UL certified to Description certified to Number ANSI/ISEA EN standards Eyewashes S19314EW Halo Eyewash, plastic showerhead & bowl S19314P* Halo Eyewash, plastic showerhead & bowl w/ hose spray S19314SB Halo Eyewash, plastic showerhead, stainless steel bowl ...
Page 28
S19314 Installation Halo Pre-Configured Models All models with DIN-DVGW, AS4775 & AS/NZS 4020 Certification include stainless steel pipe material with BSPP threading. DIN-DVGW IAPMO Oceana Halo Model certified to Description certified to Number DIN EN 15154-1 & AS4775 & AS4020 DIN EN 15154-2 Eyewashes ...
S19314 Installation Halo Configurator Bowl and Dust Cover Standard Selections (Must select one from each category) ¨ A Plastic Bowl, No Dust Cover Configuration ¨ B Plastic Bowl, Plastic Dust Cover ¨ A Barrier Free ¨ D 304 SS, No Dust Cover ¨ B 24"...
S19314 Installation Assembly — Connect Base and Eyewash Standard eyewash unit is shown. Other units are similar. Connect components before securing the base to the floor. When connecting components, use the rubber grip pad (provided) around pipes to prevent marring. Apply pipe sealant (supplied by installer) to all male-threaded pipe joints, making sure not to get any excess over the edge of the pipes.
Page 32
S19314 Installation BSPP-NPT Assembly — Connect Drench Shower Components 1-1/4" Adapter if supplied with provided Stainless Standard eyewash unit is shown. Other units are similar. option steel tee with reducer Apply pipe sealant (supplied by installer) to all male-threaded pipe joints, making sure not to get any excess over the edge of the pipes.
S19314 Installation Service Parts — Bowl and Hub Cross (Item #3) is for use with freeze/scald valves and drench hose accessories only. Hub with Plastic Bowl Hub with Stainless Steel Bowl Bradley • 215-1684 Rev. P; ECN 15-05-019 8/5/2015...
Page 34
S19314 Installation Service Parts List — Bowl and Hub Item Part No. Description Item Part No. Description 111-092 113-1202 Pipe 1¼" x 11" thd . one end 111-093 Hub stainless steel 113-1203 Pipe 1¼" x 11" thd . one end stn . steel 111-095 Hub stainless steel 316 113-1204...
S19314 Installation Service Parts — Eyewash Service Parts — Eye/Face Wash Prepack S65-339 includes items 26, 27, 28 Eyewash Cover Prepack Eye/Face Wash Cover Prepack S45-2675 includes items S45-2676 includes items 22, Prepack S88-068 includes items 25, 26, 27, 28 22 and 23 24a and 24b Prepack S88-069 includes items 25, 26, 27, 28 (300 series ss)
Page 36
S19314 Installation Service Parts — Plastic Bowl Cover Plastic Bowl Cover Prepack S90-390 includes items 35a, 36, 39, 42, 43 Service Parts — Stainless Steel Bowl Cover Stainless Steel Bowl Cover Prepack S90-388 includes items 35b, 36, 39, 42, 43 Stainless Steel (316) Bowl Cover Prepack S90-389 includes items 35b, 36, 39, 42, 43...
Page 37
S19314 Installation Service Parts List — Eyewash, Eye/Face Wash and Bowl Covers Item Part No. Description Item Part No. Description 171-001 Body 125-157 O-ring 171-002 Body stainless steel 125-175 Flow control 171-003 Body stainless steel 316 S65-340 Screen (incl. 3 per pack) 171-004 Body polished in service kit...
S19314 Installation Service Parts and Parts List — Base and Drain Foot Pedal kits S45-572 (standard foot pedal kit) S45-1314SS (stainless steel foot pedal kit) S45-1314SS16 (316 stainless steel foot pedal kit) Supplied 301a 301b with BSPP Thread options only 302b 302a Base and Drain Kits for 24"...
S19314 Installation Service Parts — Drench Shower ll s Ü F ti g L IC s ig s tä P .O ly . e ld Ö C a in p rü A IR e tr R Ä e (s s tb c ti S tö...
Page 40
S19314 Installation Service Parts — Drench Shower BSPP Adapter - Supplied with BSPP Thread options only Stainless Steel Valve Prepacks include items 350b, 354b, 355b S30-061 (for stainless steel valve) S30-081 (for 316 stainless steel valve) S30-104 (for frost-proof stainless steel valve) 350b 355b.1 350a...
Page 41
S19314 Installation Parts List — Showerhead and Shower Valves BSP = British Standard Pipe Thread (not available in the U.S.) Item Part No. Description Item Part No. Description 169-727 Tee 1¼" painted galvanized 269-915 Rubber Grip Pad 169-727B Tee 1¼" painted galvanized BSP 204-421 Emergency Inspection Tag 269-237...
3UG73E and 3UG74E Operating Instructions & Parts Manual Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference.
3UG73E and 3UG74E Dayton Operating Instructions and Parts Manual Dayton Electric Utility Heaters ® General Safety 12. This heater is intended for comfort High temperature, risk of fire; keep heating applications and not intended Information electrical cords, drapery, furnishings, for use in special environments. Do and other combustibles at least 3 feet not use in damp or wet locations such (Continued)
Page 44
Dayton Operating Instructions and Parts Manual Models 3UG73E and 3UG74E Installation NOTE: If you want to swivel the heater either to the right or left, adding a Instructions washer to both sides of the bracket is recommended. A longer lag bolt may (Continued) be required to properly secure the unit (see Figure 4a).
3UG73E and 3UG74E Dayton Operating Instructions and Parts Manual Dayton Electric Utility Heaters ® Installation WIRING NOTE: 1. Do not move blue wire at L1. Instructions LIMIT (Table 1 refers to blue wire (Continued) at terminal T.) ELEMENT 2. It is recommended that NOTE: For certain applications, conduit CONT.
Page 46
Dayton Operating Instructions and Parts Manual Models 3UG73E and 3UG74E Operation 8. It may be necessary to readjust the user that the heater is off and the thermostat until exact comfort level cause of the overheating should be Instructions is attained. Rotation in the clockwise determined and corrective action direction will increase the amount should be taken before further...
3UG73E and 3UG74E Dayton Operating Instructions and Parts Manual Dayton Electric Utility Heaters ® Operation USER CLEANING INSTRUCTIONS USER CLEANING INSTRUCTIONS 1. After the heater has cooled, a vacuum 1. After the heater has cooled, a vacuum Instructions cleaner with brush attachment may cleaner with brush attachment may (Continued) be used to remove dust and lint from...
3UG73E and 3UG74E Dayton Operating Instructions and Parts Manual For Repair Parts, call 1-800-Grainger 24 hours a day – 365 days a year Please provide following information: -Model number -Serial number (if any) -Part description and number as shown in parts list Figure 12 –...
3UG73E and 3UG74E Dayton Operating Instructions and Parts Manual Dayton Electric Utility Heaters ® LIMITED WARRANTY DAYTON ONE-YEAR LIMITED WARRANTY. DAYTON ® ELECTRIC UTILITY HEATERS, MODELS COVERED IN THIS MANUAL, ARE WARRANTED BY DAYTON ELECTRIC MFG. CO. (DAYTON) TO THE ORIGINAL USER AGAINST DEFECTS IN WORKMANSHIP OR MATERIALS UNDER NORMAL USE FOR ONE YEAR AFTER DATE OF PURCHASE.
Need help?
Do you have a question about the PRO-GUARD and is the answer not in the manual?
Questions and answers