Amana distinctions DCP073A25AA Manual page 9

Packaged terminal air conditioner / heat pump
Hide thumbs Also See for distinctions DCP073A25AA:
Table of Contents

Advertisement

Figure 3
No.
S1
S2
Temperature Display in °F
S3
Wall Thermostat Enable
S4*S5
S6
Fan Continuous Run for Heating
S7
Fan Continuous Run for Cooling
S8
Low temp. Protection enable
S9 (S3
Use some types of wall
UP)
S9 (S3
Use Control Panel Only
DOWN)
Sw11
TABLE 1 DIP SWITCH CONFIGURATIONS
NOTE: On heating mode, the setting temperature
can not be higher than 29°C / 84°F.
Wall Thermostat Enable
A wired wall thermostat can be connected to the unit. If it is,
this dip switch must be moved to the Wall Thermostat En-
able Position before the wall thermostat will begin control.
Low Temperature Protection (Optional)
If unit senses a room temperature below 32°F (0°C), the
fan motor and electric strip heat will turn on and warm the
room to 40°F (4.4°C). The fan stops a short time after the
temperature is satisfied.
UP (ON)
Electric Heat Only
UP*UP: 61°F - 86°F (16°C - 30°C);
UP*DOWN: 65°F - 78°F (17°C - 26°C);
DOWN*UP: 63°F - 80°F (17°C - 27°C);
DOWN*DOWN: 68°F - 75°F (20°C - 24°C);
Thermostat
Load delay for 3 sec.
Down (OFF)
Electric Heat and Pump Heat
Temperature Display in °C
Control Panel Enable
Fan Cycle for Heating
Fan Cycle for Cooling
Low temp. Protection disable
Use PTAC other wall Thermostat
Use Control Panel or some types
of wall Thermostat
Normal
Electric Heat Only (For Heat Pump Unit Only)
This setting is typically used for Emergency Heating.
Heat and Cool Fan CON / CYC DIP-Switches
Allows the fan to operate in continuous or cycle modes
while the unit is in heating and cooling mode.
CON (Continuous)
Allows the fan to operate in time after the temperature
setting is satisfied. This switch helps to maintain the room
temperature closer to the thermostat setting.
CYC (Cycle)
This setting allows the fan to cycle on and off with the com-
pressor or electric heater. The fan stops a short time after
the temperature setting is satisfied.
9
Figure 4
Remarks
For Heat Pump unit only
Two Configurations
(S4*S5) combine to select
set point range.
Optional
You can consult with the
sales agency or
manufacturer for details.
Use Control Panel or
some types of wall
Thermostat, the other one
must be turned off.
Optional

Advertisement

Table of Contents
loading

Table of Contents