  • Page 1 Security & Home Automation System QUICK USER & INSTALLER MANUAL (REVISION 2.0)
  • Page 2: Automation Control

    T Sense Keypad Quick User & Installer Manual Rev 2.0 ARM AND DISARM SYSTEM Default Master Pin 111 111 QUICK ARM ARM with PIN DISARM With PIN ▪ Press [Master PIN] + [#] ▪ Press [Master PIN] + [#] Auto Home ▪...
  • Page 3: Clear Alarm Memory

    T Sense Keypad Quick User & Installer Manual Rev 2.0 CLEAR ALARM MEMORY COMMAND INFORMATION ▪ Press & hold button [6] for 2 seconds ▪ Clear Zones, Strobe Light & Ext Comm. Error DOOR CHIME COMMAND ▪ Hold [7] for 2 sec + [Zone number 01 to 16] + [#] REMARKS -When door chime is activated, the keypad will sound each time the designed zone is triggered SYSTEM SERVICE...
  • Page 4: Keypad Setting

    T Sense Keypad Quick User & Installer Manual Rev 2.0 KEYPAD SETTING Keypad Setting Command Partition Option Press [▼] for 2 sec + [▼ for PART] + [Press 1 to toggle] + [#] ON/OFF Keypad backlight Press [▼] for 2 sec + [▼ for LIGHT] + [Press 1 to toggle] + [#] ON/OFF keypad Arm tone Press [▼] for 2 sec + [▼...
  • Page 5: User Programming Summary

    T Sense Keypad Quick User & Installer Manual Rev 2.0 USER PROGRAMMING SUMMARY Default Master Pin 111 111 Description Command Enter User Programming Mode [Master Pin] + [COM] + [#] Exit User Programming Mode Press and Hold [*] for 2 sec Edit Master Pin [▼...
  • Page 6 T Sense Keypad Quick User & Installer Manual Rev 2.0 INSTALLER PROGRAMMING SHEET Default Installer Pin 12345 Enter Installer programming mode: [INSTALLER CODE] + [COM] + [#] Symbol: Exit Installer programming mode: Press and hold [*] for 2  Enable seconds ...
  • Page 7 T Sense Keypad Quick User & Installer Manual Rev 2.0 Reporting Setting Telephony Zone 1 ON mean enable DTMF   TEL CT Control Dialling ELSE Pulse Dialling Zone 2 ON mean enable Double Call Zone 1 ON mean Receiver 1 is RCV TY Receiver Type Personal Reporting else CMS...
  • Page 8 T Sense Keypad Quick User & Installer Manual Rev 2.0 Remark : Based on Communication Option’s Table (Refer previous table, page 6) - Enter [0000] # to delete/clear CMS account number -Press [31] to enter command and press [1] # to set receiver type as personal type to disable CMS account number Zone Circuit Type Setting Zone number ON means the zone End of Line...
  • Page 9 From 1 to 255 times of password LOCK C 010# Counter error before keypad lock LOCK T Keypad Lock Time From 0 to 255 minutes 003# Change installer INS CD 5 digits installer code 12345# code DAIKIN ELECTRONIC DEVICES MALAYSIA SDN BHD...