Download Print this page
Marantz PD4230V User Manual
Marantz PD4230V User Manual

Marantz PD4230V User Manual

External control
Hide thumbs Also See for PD4230V:

Advertisement

Quick Links

Marantz plasma Monitor
RS232C: External Control Manual
(for PD4230V/PD4240D/PD5050D/PD6150D)

Advertisement

loading
Need help?

Need help?

Do you have a question about the PD4230V and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Marantz PD4230V

  • Page 1 Marantz plasma Monitor RS232C: External Control Manual (for PD4230V/PD4240D/PD5050D/PD6150D)
  • Page 2 Application These specifications communications control from external equipment. "Please also support the command of VP series and refer to the manual of the conventional model about specification." Connections Connections should be made as described below. plasma monitor 1) Connector on the plasma monitor side: EXTERNAL CONTROL connector. Type of connector: D-Sub 9-pin male No.
  • Page 3: Communication Parameters

    2) Connector on the external equipment side: Serial port (RS-232C) connector. See the specifications of the equipment that is to be connected for the type of connector and the pin assignment. 3) Wiring Use a crossed (reverse) cable. Wire the cable so that each pair of data lines cross between the two devices. These data line pairs are RXD (Receive data) and TXD (Transmit data), DTR (DTE side ready) and DSR (DCE side ready), and RTS (Ready to send) and CTS (Clear to send).
  • Page 4 Communication Format 8bit Command 1 Unit ID 1 Unit ID 2 Command 2 Data length Data Check sum Command1 Command 1, along with command 2, is a number used to distinguish each command. When making it operate using ID, bit1 and bit0 are set up as follows. Bit1,Bit0 Unit ID distinction bit :Usually, a form (with no ID) :Usually, a form (with no ID)
  • Page 5 1) Unit ID 1: Indicates the equipment sending the signal. When supporting Set ID by the command 1, 4 bits of low ranks of Set ID are set up. 2) Unit ID 2: Indicates the equipment receiving the signal. When supporting Set ID by the command 1, 4 bits of higher ranks of Set ID are set up.
  • Page 6 Command 2 Command 2, along with command 1, is a number used to distinguish each command. Check Sum (CKS), Error Processing, and ACK 1) The check sum described below and RS-232C odd parity are used together for a check of the received data. The check sum is the lower order 8 bits of one frame of sent or received data comprising the sum total of Command 1, Unit ID 1 and 2, Command 2, Data Length, and Data.
  • Page 7 The control method of the set by Set ID When controlling two or more sets of plasma monitors, if the command using Set ID is used, it will become controllable individually. The example of the POWER ON command to the plasma monitor which set ID as "5"...
  • Page 8: Command Reference List

    Command Reference List Power ON Power OFF Input Switch Change VOLUME Gain Data AUDIO Mute ON AUDIO Mute OFF CONTRAST Gain Data BRIGHT Gain Data SHARPNESS Gain Data Color Gain Data TINT Gain Data PICTURE MODE Select COLOR TEMP SELECT RED Gain Data GREEN Gain Data BLUE Gain Data...
  • Page 9 LANGUAGE Select COLOR SYSTEM Select FREQUENCY Request Input MODE Request VIDEO ADJ Request Audio Select Request Failure Mode Request MODEL NAME Request D-SUB INPUT LOW TONE COLOR TUNE GAMMA Gain Data Running Sense OSM OBITER Input Skip SERIAL No. Request S1/S2 SELECT SOFT FOCUS PLUG and PLAY...
  • Page 10 01. Power ON Function The external control equipment switches on the power of the plasma monitor. Transmission Data 9FH 80H 60H 4EH 00H CKS The plasma monitor returns the following ACK when the power is switched 3FH 60H 80H 4EH 00H CKS NOTE: Do not set the Power ON or Power OFF command continuously.
  • Page 11 03. Input Switch Change Function The external control equipment switches the input of the plasma monitor. Transmission Data DFH 80H 60H 47H 01H DATA00 DATA00 : Input Select The plasma monitor returns the following ACK when the input is switched. 3FH 60H 80H 47H 00H CKS 01H : Video1 02H : Video2...
  • Page 12 04. VOLUME Gain Data Function The external control equipment changes the VOLUME gain data of the plasma monitor. Transmission Data DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS DATA00: USER SOUND Gain Flag 05H DATA01: VOLUME Gain Flag DATA02: VOLUME Gain 7FH 60H 80H 7FH 02H DATA00 DATA00: USER SOUND Gain Flag DATA01: VOLUME Gain Flag...
  • Page 13 07. CONTRAST Gain Data Function The external control equipment changes the CONTRAST gain data of the plasma c Transmission Data DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS DATA00 : USER PICTURE Gain Flag DATA01 : CONTRAST Gain Flag DATA02 : CONTRAST Gain 7FH 60H 80H 7FH 02H DATA00 DATA01 CKS DATA00: USER PICTURE Gain Flag...
  • Page 14 DATA00 : USER PICTURE Gain Flag DATA01 : BRIGHT Gain Flag 09. SHARPNESS Gain Data Function The external control equipment changes the SHARPNESS gain data of the plasma monitor. Transmission Data DFH 80H 60H 7FH 03H DATA00 DATA00 : USER PICTURE Gain Flag DATA01 : SHARPNESS Gain Flag DATA02 : SHARPNESS Gain Only when a RGB signal is connected...
  • Page 15 10. COLOR Gain Data Function The external control equipment changes the COLOR gain data of the plasma monitor. Transmission Data DFH 80H 60H 7FH 03H DATA00 DATA00 : USER PICTURE Gain Flag DATA01 : COLOR Gain Flag DATA02 : COLOR Gain * COLOR Gain is from -22 (EAH) to +22 (16H) only during video.
  • Page 16 7FH 60H 80H 7FH 02H DATA00 : USER PICTURE Gain Flag DATA01 : TINT Gain Flag 12. PICTURE MODE Select Function The external control equipment sets the picture mode of the plasma monitor. Transmission Data DFH 80H 60H 0AH 01H DATA00 DATA00: 01H : NORMAL 02H : THEATER1(It cannot choose in the still picture input of a 03H : THEATER2(It cannot choose in the still picture input of a...
  • Page 17 7FH 60H 80H 00H 01H DATA00 DATA00 : 00H: low 01H: middle 02H: high 03H: middle low 14. RED Gain Data Function The external control equipment changes the RED Gain Data of the plasma monitor. Transmission Data DFH 80H 60H 7FH 04H DATA00 to DATA03 CKS DATA00 : USER PICTURE Gain Flag DATA01 : RED Gain Flag DATA02 : RED Gain1(Bias)
  • Page 18 15. GREEN Gain Data Function The external control equipment changes the GREEN Gain Data of the plasma monitor. Transmission Data DFH 80H 60H 7FH 04H DATA00 to DATA03 CKS DATA00 : USER PICTURE Gain Flag DATA01 : GREEN Gain Flag DATA02 : GREEN Gain1(Bias) DATA03: GREEN Gain2(Drive) 7FH 60H 80H 7FH 02H DATA00...
  • Page 19 16. BLUE Gain Data Function The external control equipment changes the BLUE Gain Data of the plasma monitor. Transmission Data DFH 80H 60H 7FH 04H DATA00 to DATA03 CKS DATA00 : USER PICTURE Gain Flag DATA01 : BLUE Gain Flag DATA02 : BLUE Gain1(Bias) DATA03: BLUE Gain2(Drive) 7FH 60H 80H 7FH 02H DATA00 DATA01...
  • Page 20 17. NR MODE Set Function The external control equipment sets the NR (Noise Reduction) mode of the plasma monitor. Transmission Data DFH 80H 60H C0H 01H DATA00 DATA00: 01H : NR OFF 02H : NR-1 03H : NR-2 04H : NR-3 7FH 60H 80H C0H 01H DATA00 DATA00: 01H : NR OFF 02H : NR-1...
  • Page 21 19. TREBLE Gain Data Function The external control equipment changes the TREBLE gain data of the plasma monitor. Transmission Data DFH 80H 60H 7FH 03H DATA00 DATA00 : USER PICTURE Gain Flag DATA01 : TREBLE Gain Flag DATA02 : TREBLE Gain 7FH 60H 80H 7FH 02H DATA00 DATA01 CKS DATA00: USER PICTURE Gain Flag DATA01: TREBLE Gain Flag...
  • Page 22 DATA01: BALANCE Gain Flag 21.SCREEN MODE Select Function The external control equipment switches the screen mode of the plasma monitor. Transmission Data DFH 80H 60H 51H 01H DATA00 DATA00 02H : STADIUM 03H : ZOOM 04H : NORMAL 05H : ANAMORHIC(FULL) 06H : REAL 08H : UNDERSCAN 09H : 14:9...
  • Page 23 22. V.POSITION Gain Data Function The external control equipment changes the V. POSITION gain data of the plasma monitor. Transmission Data DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 DATA00 : USER PICTURE Gain Flag DATA01 : V.POSITION Gain Flag DATA02 : V.POSITION Gain 7FH 60H 80H 7FH 02H DATA00 DATA01 DATA00: USER PICTURE Gain Flag...
  • Page 24 23. H.POSITION Gain Data Function The external control equipment changes the H. POSITION gain data of the plasma monitor. Transmission Data DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS DATA00 : USER PICTURE Gain Flag DATA01 : H.POSITION Gain Flag DATA02 : H.POSITION Gain 7FH 60H 80H 7FH 02H DATA00 DATA00: USER PICTURE Gain Flag...
  • Page 25 25. H.WIDTH Gain Data Function The external control equipment changes the H-WIDTH gain data of the plasma monitor. Transmission Data DFH 80H 60H 7FH 03H DATA00 DATA00 : USER PICTURE Gain Flag DATA01 : H-WIDTH Gain Flag DATA02 : H-WIDTH Gain 7FH 60H 80H 7FH 02H DATA00 DATA00: USER PICTURE Gain Flag DATA01: H-WIDTH Gain Flag...
  • Page 26 27. PHASE(FINE PICTURE) Gain Data Function The external control equipment changes the PHASE gain data (Phase) of the plasma monitor. Transmission Data DFH 80H 60H 7FH 03H DATA00 DATA00 : USER PICTURE Gain Flag DATA01 : PHASE Gain Flag DATA02 : PHASE Gain 7FH 60H 80H 7FH 02H DATA00 DATA00: USER PICTURE Gain Flag DATA01: PHASE Gain Flag...
  • Page 27 29. OSM ADJ. POSITION Data Function The external control equipment sets the position of the OSM menu of the plasma monitor. Transmission Data DFH 80H 60H 1AH 02H DATA00 DATA00 : OSM ADJ. Gain Flag DATA01 7FH 60H 80H 1AH 01H DATA00 CKS DATA00 : OSM ADJ.
  • Page 28 Transmission Data DFH 80H 60H C6H 01H DATA00 CKS DATA00 : GRAY LEVEL 7FH 60H 80H C6H 01H DATA00 CKS DATA00 : GRAY LEVEL 32. CINEMA MODE Set Function The external control equipment switches on or off the CINEMA MODE of the plasma monitor.
  • Page 29 33. LONG LIFE Set(PDP SAVER Set) Function The external control equipment sets the PLE, ORBITER, and INVERSE (inverse of image brightness) or WHITE of the plasma monitor. Transmission Data DFH 80H 60H 6BH 03H DATA00 DATA00 : PLE DATA01 : INVERSE/WHITE DATA02 : ORBITER (PICTURE SHIFT) The plasma monitor returns the following ACK when setting the PLE, ORBITER, and INVERSE (inverse of image brightness) or WHITE:...
  • Page 30: All Reset

    34. SCREEN WIPER Set Function The external control equipment sets the SCREEN WIPER of the plasma monitor. Transmission Data DFH 80H 60H C8H 04H DATA00 to DATA03 CKS DATA00 : SCREEN WIPER DATA01 : DATA02 : DATA03 : 3FH 60H 80H C8H 00H CKS 35.
  • Page 31 36. Audio Select Set Function The external control equipment sets combinations of audio and video inputs for the plasma monitor. Transmission Data DFH 80H 60H 70H 02H DATA00 DATA00 : AUDIO INPUT DATA01 : VISUAL INPUT The plasma monitor returns the following ACK when the input is switched. 3FH 60H 80H 70H 00H CKS * The plasma monitor returns “Not Available”...
  • Page 32: Bnc Input

    37. BNC INPUT Function The external control equipment sets the BNC SELECT of the plasma monitor. Transmission Data DFH 80H 60H 8CH 01H DATA00 CKS DATA00 : BNC SELECT The plasma monitor returns the following ACK when setting the BNC SELECT: 7FH 60H 80H 8CH 01H DATA00 CKS DATA00 : BNC SELECT 38.
  • Page 33 05H : WIDE2 06H : DTV 07H : WIDE3 08H : WIDE4 39. HD Select Function The external control equipment sets the HD SELECT of the plasma monitor. Transmission Data DFH 80H 60H 8AH 01H DATA00 DATA00 01H : 1035I 02H : 540P(1080A) 03H : 1080I(1080B) 7FH 60H 80H 8AH 01H...
  • Page 34 DATA00: 01H : ENGLISH 02H : GERMAN 03H : FRENCH 04H : SPANISH 05H : ITALIAN 06H : SWEDISH 0AH : CHINESE 0BH : RUSSIAN 41. COLOR SYSTEM Select Function The external control equipment sets the COLOR SYSTEM of the plasma monitor.
  • Page 35 42. FREQUENCY Request(SIGNAL INFORMATION) Function The external control equipment inquires the Horizontal frequency, Vertical frequency, Horizontal sync polarity, Vertical sync polarity, Mode, and Resolution of the plasma monitor. Transmission Data 1FH 80H 60H 26H 00H CKS 7FH 60H 80H 26H 0BH DATA00 to DATA0A CKS Horizontal frequency DATA00: Integer part DATA01: One decimal place...
  • Page 36 MODE DATA06 01H to 80H mode RESOLUTION DATA07: Dots (Low-order byte) 00H: 0 (No signal: 00H) DATA08: Dots (High-order byte) 00H: 257 (No signal: 00H) DATA09: Lines (Low-order byte) 00H: 0 (No signal: 00H) DATA10: Lines (High-order byte) 00H: 257 (No signal: 00H) No signal −...
  • Page 37 43. Input MODE Request Function The display returns the current input information by the external control equipment’ s request. Transmission Data 1FH 80H 60H 41H 00H CKS 7FH 60H 80H 41H 01H DATA00 DATA00 : Input Select 44. VIDEO ADJ. Request Function The display returns the video adjustments information by the external control equipment’s request.
  • Page 38 DATA01: GREEN Gain (Bias) DATA02: BLUE Gain (Bias) DATA03: COLOR Gain * COLOR Gain is from -22 (EAH) to FFH : -01 +22 (16H) only during video. DATA04: TINT Gain * TINT Gain is from -22 (EAH) to +22 (16H) only during video. DATA05: SHARPNESS Gain DATA06: CONTRAST Gain D8H : -40...
  • Page 39 DATA07: BRIGHT Gain DATA08: RED Gain (Drive) DATA09: GREEN Gain (Drive) DATA0A: BLUE Gain (Drive) FFH : -01 00H : 0 01H : +01 14H : +20 E0H : -32 FFH : -01 00H : 0 01H : +01 20H : +32 D8H : -40 FFH : -01 00H : 0...
  • Page 40 DATA0B: COLOR TEMP SELECT 45. Audio Select Request Function The external control equipment inquires the current combinations of audio and video inputs for the plasma monitor. Transmission Data 1FH 80H 60H 6FH 00H CKS The plasma monitor returns the following ACK: 7FH 60H 80H 6FH 03H DATA00 DATA01 DATA00 : AUDIO1 01H-0CH : VISUAL INPUT DATA...
  • Page 41 46. Failure Mode Request Function The external control equipment inquires the detection of failures of the plasma monitor. Transmission Data 1FH 80H 60H 3FH 00H CKS The plasma monitor returns the following ACK: 7FH 60H 80H 3FH 02H DATA00 DATA00: FAILURE MODE 1 Bit 0 : PDP MODULE 0: Abnormal 1: Normal...
  • Page 42 47. MODEL NAME Request Function The external control equipment inquires the product code of the plasma monitor. Transmission Data 1FH 80H 60H 17H 00H CKS The plasma monitor returns the following ACK: 7FH 60H 80H 17H 0CH DATA00 to DATA11 CKS DATA00 : 1st character of the product code DATA01 : 2nd character of the product code DATA11 : 12th character of the product code...
  • Page 43 If there are fewer than 12 characters in the product code, product code would be padded right with blanks. Example: If the product code of your plasma monitor is “50XGA”, the returned codes would be as follows. DATA00:05H, DATA01:00H, DATA02:27H, DATA03:16H, DATA04:10H, DATA05:96H, DATA06:96H, DATA07:96H, DATA08:96H, DATA09:96H, DATA10:96H, DATA11:96H...
  • Page 44 48. D-SUB INPUT Function The external control equipment sets the D-SUB SELECT of the plasma monitor. Transmission Data DFH 80H 60H 8DH 01H DATA00 CKS DATA00 : D-SUB INPUT The plasma monitor returns the following ACK when setting the D-SUB SELECT: 7FH 60H 80H 8DH 01H DATA00 CKS DATA00 : D-SUB INPUT...
  • Page 45 50.COLOR TUNE Function External control equipment can adjust RGB each color which a plasma monitor wants to emphasize. Transmission Data DFH 80H 60H 0DH 07H DATA00 to DATA06 CKS DATA00:RED DATA01:GREEN DATA02:BLUE DATA03:YELLOW DATA04:MAZENTA DATA05:CYAN 00H : -32 20H : 0 40H : +32 00H : -32 20H : 0...
  • Page 46 DATA06:RESET 7FH 60H 80H 0DH 00H CKS 51.GAMMA GAIN Data Function External control apparatus changes Gamma of a plasma monitor. Transmission Data DFH 80H 60H 13H 02H DATA00 DATA01 CKS DATA00: GAMMA FLAG DATA01: GAMMA 7FH 60H 80H 13H 01H DATA00 CKS DATA00: GAMMA FLAG 00H : OFF 01H : ON...
  • Page 47 52.Running Sense Function External control apparatus grasps the power supply state of a plasma monitor. A plasma monitor is made to recognize connection of PC CONTROL. Transmission Data 1FH 80H 60H 88H 00H CKS 7FH 60H 80H 88H 01H DATA CKS DATA: Bit0:Connect Condition 0: No connection 1: Connected...
  • Page 48 53. OSM OBITER Function In order to decrease printing of a screen by OSM display, whenever it displays OSM, shift operation of the OSM is carried out. Transmission Data DFH 80H 60H 5FH 01H DATA00 DATA00 01H : OBITER ON 02H : OBITER OFF 7FH 60H 80H 5FH 01H DATA00 DATA00...
  • Page 49 55. SERIAL No. Request Function External control apparatus read EEPROM of a plasma display. Transmission Data 1FH 80H 60H 15H 00H CKS 7FH 60H 80H 15H 0CH DATA00 to DATA11 CKS Even DATA00-DATA11 is set up as follows. Setting value 56.S1/S2 SELECT Function External control apparatus sets up the S1/S2 detection of a plasma monitor.
  • Page 50 57.SOFT FOCUS Function External control apparatus sets up the Soft Focus of a plasma monitor. Transmission Data DFH 80H 60H 65H 01H DATA00 01H : OFF 02H : LEVEL1 03H : LEVEL2 04H : LEVEL3 05H : LEVEL4 7FH 60H 80H 65H 01H DATA00 01H : OFF 02H : LEVEL1 03H : LEVEL2...
  • Page 51 59.BLACK LEVEL SELECT Function External control apparatus sets up the black level (digital signal level) of a plasma monitor. Transmission Data DFH 80H 60H 8FH 01H DATA00 01H : LOW 02H : HIGH 7FH 60H 80H 8FH 01H DATA00 01H : LOW 02H : HIGH 60.OSM CONTRAST SELECT Function...
  • Page 52 61. PICTURE MEMORY Select Function The external control equipment selects the Picture Memory function of a plasma monitor. Transmission Data DFH 80H 60H 38H 01H DATA00 DATA00 : MEMORY select 00H : OFF The plasma monitor returns the following ACK when the input is switched. 7FH 60H 80H 38H 01H CKS DATA00 : 62.
  • Page 53 The plasma monitor returns the following ACK when the input is switched. 7FH 60H 80H 25H 01H CKS DATA00 : NOTE: When “PICTURE MEMORY” selects “OFF”, this command is no support. 63. PICTURE MEMORY NOTE WRITE Set Function External control apparatus writes to NOTE of PICTURE MEMORY o plasma display.
  • Page 54: Back Ground Select

    Corresponding character Received data (H) Corresponding character Received data (H) 3FH 60H 80H 2DH 00H CKS NOTE) Please select the memory you like to write by “68.PICTURE MEMORY Select” before setting “PICTURE MEMORY NOTE WRITE” 64.SET UP LEVEL SELECT Function External control apparatus selects the Set up level function of a plasma monitor.
  • Page 55 02H : Gray 7FH 60H 80H 36H 01H DATA00 01H : Black 02H : Gray 66. Audio HDMI input Select Request Function The external control equipment requests combination of audio and HDMI input for the plasma monitor. Transmission Data 1FH 80H 60H 3AH 00H CKS The plasma monitor returns the following ACK when the input is switched.

This manual is also suitable for:

Pd4240dPd4250dPd5050dPd6150dRs232c