Advertisement

Quick Links

Orion-M
Honeywell UDC2500/3200
Controller System Guide
Orion-M Honeywell UDC2500/3200 Series Controller System Guide Rev C
February 7, 2011
Supersedes: Rev B (March 25, 2010)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Orion-M and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for FDC Orion-M

  • Page 1 Orion-M Honeywell UDC2500/3200 Controller System Guide Orion-M Honeywell UDC2500/3200 Series Controller System Guide Rev C February 7, 2011 Supersedes: Rev B (March 25, 2010)
  • Page 2 CAUTION or WARNING safety statement. Technical Assistance If you encounter a problem with your Orion-M controller, review all of your configuration information to verify that your selections are consistent with your application: inputs; outputs; alarms; limits; etc. If the problem persists after checking the above, you can get technical assistance by dialing +1 (866) 342-5332 or by faxing your request to +1 (866) 332-8014, Monday thru Friday, 8:00 a.m.
  • Page 3: Table Of Contents

    Orion-M What is the Orion-M? ....................1.1 Features............................... 1.1 Getting Started......................2.1 Installing the UDC2500/3200 Controller....................2.1 2.1.1 Communications Wiring ........................ 2.1 Configuring the Honeywell UDC2500/3200 Controller .......... 3.1 Assigning the Proper Communications Settings ................. 3.1 Input Type Assignments ........................3.2 3.2.1...
  • Page 5: What Is The Orion-M

    The Orion-M provides a configurable control platform for a variety of OEM applications requiring up to 15 separate loops of control. In addition to 15 loops of control, the Orion-M can also provide up to an additional 15 inputs for process monitoring, for a total of 30 process inputs.
  • Page 6 Orion-M system. The Orion-M can store more than one year of data on its internal compact flash card. Data logging can be enabled manually or automatically during automatic profile run. Data backup is provided with the ‘USB I- Stick’...
  • Page 7: Getting Started

    The Orion-M requires one Honeywell UDC2500 or UDC3200 for each control loop required in the system. Since the Orion-M is capable of interfacing to more than one brand of controller, refer to the Orion-M part number matrix for the operating system to be sure that the HWSL, CM application software has been provided.
  • Page 8 Refer to the Honeywell UDC2500 or UDC3200 Product Manual for all other connections including power, sensor and control wiring. Since no two applications are the same, it is up to the system designer to insure that the controllers are properly installed and wired to meet design specifications. FDC Orion-M GETTING STARTED...
  • Page 9: Configuring The Honeywell Udc2500/3200 Controller

    The Orion-M only requires that the communications settings for each loop control be properly assigned, and that the input type of the controller is set in the Orion-M Configurator, so that the control loop input and set point can be displayed and set properly through the Orion-M interface.
  • Page 10: Input Type Assignments

    Orion-M Configurator. The decimal point selection for the Loop Input in the Orion-M and the UDC controller do not have to be set to match; however, if the loop controls are visible to the operator, it is recommended that the decimal point resolution of the Orion- M and UDC controller match.
  • Page 11: Input 2 Operation

    The Loop Input 2 monitor point selection allows inputs to be displayed on the Orion-M with a resolution of 0 to 3 decimal points. The Orion-M has a display range of -32768 to 32767, -3276.8 to 3276.7, -327.68 to 327.67 or -32.768 to 32.767 depending upon decimal point selection.
  • Page 12 Orion- M. These can allow an operator to make changes at the loop control in cases where the Orion-M interface is located in a remote location.
  • Page 13: Appendix

    Orion-M Appendix APPENDIX FDC Orion-M...
  • Page 14: Software Usage Note

    In addition, Future Design reserves the right to make changes without notification to purchaser or user to materials or processing that do not affect compliance with any applicable specification. Future Design makes no warranties when using the Orion-M system. Warranty:...

Table of Contents