1. GENERAL
1.1
It is important these Installation and Maintenance Instructions are fully adhered to.
1.2
Full details of the unit supplied are shown on the product nameplate.
If in doubt about any detail, contact FANTECH or its agents for clarification.
1.3
Electrical installation must be carried out by suitably qualified and competent personnel in accordance
with all current statuary requirements.
1.4
Any declarations made by FANTECH about product installation and safety,
are dependent on the air curtain being used within installations which themselves meet the
requirements of the relevant Standards and Directives of your region.
1.5
The air curtain must be installed in a dry, sheltered position and is not suitable for operating in
temperatures above 40 °C. The air curtain is not suitable in corrosive or explosive atmospheres.
1.6
The installer should provide easy access to the air curtain to facilitate future maintenance.
1.7
The installer should ensure the air curtain is adequately supported.
1.8
This product is not intended for use by young children or infirm persons unless they have been
adequately supervised by a responsible person to ensure that they can use the product safely. Young
children should be supervised to ensure that they do not play with the appliance.
SPECIFICATIONS
Voltage
Frequency
Model
(V)
AC1209
230
AC1212
230
AC1215
230
Part No: INST-AIRCURTAIN
These instructions must be read fully
before commencing installation.
Low Speed
Current
Power
(Hz)
(A)
(W)
50
0.956
220
50
1.217
280
50
1.522
350
Version 1.1
Outlet
Noise
Current
Velocity
(dB(A))
(A)
(m/s)
15
54
1.2
15
55
1.391
12.5
54
1.896
High Speed
Outlet
Power
Noise
Velocity
(W)
(dB(A))
(m/s)
276
18
57
320
18
58
436
14
57
09/21
Page 1/4

Advertisement

loading

Summary of Contents for Fantech AC1209

  • Page 1 It is important these Installation and Maintenance Instructions are fully adhered to. Full details of the unit supplied are shown on the product nameplate. If in doubt about any detail, contact FANTECH or its agents for clarification. Electrical installation must be carried out by suitably qualified and competent personnel in accordance with all current statuary requirements.
  • Page 2 2. INSTALLATION Important safety information The air curtain must not be installed in an area where there is any possibility of water/moisture ingress. The air curtain must be isolated from the power supply during installation and maintenance, and must be earthed in accordance with the local regulations.
  • Page 3 6 mounting holes (8mm bolts are used) 8 mounting holes (8mm wood screws are used) Dimensions, mm Weight Model (kg) AC1209 12.4 AC1212 1200 13.6 AC1215 1500 17.6 WARNING- Do not cover the air inlet and outlet. Only a suitably qualified and competent person may carry out maintenance after the electrical supply has been isolated.
  • Page 4 WARRANTY Scan the above QR code or visit www.fantech.com.au/warranty to view WARRANTY information online www.fantechtrade.com.au Australia: 1300 387 587 www.fantechtrade.co.nz New Zealand: 0800 106 266 info@fantechtrade.com.au Part No: INST-AIRCURTAIN Version 1.1 09/21 Page 4/4...

This manual is also suitable for:

Ac1212Ac1215