Page 3
/ hoses, brackets and other accessories. See our product catalogue for the entire overview on perma accessories. • Ensure that the lube po int is prefilled with fresh lubricant before installation. perma offers all of its lubricants in 400 g cartridges for grease guns.
Direct mounting should be preferred for all lubrication points, to protect the lubrication system against high pressure. Reducer for thread connection Indoors, perma NOVA can be installed in any mounting position. Outdoors or in moist areas, mounting position must be vertical (outlet pointing down) or horizontal! 360°...
Page 5
Keep in mind that tube / hose length and bore diameter of bearing housings affect pressure and discharge period of the lubrication system. • For installation of perma NOVA use Mounting bracket 1-point G1/4 female (109685). • Secure tubes / hoses with suitable fastenings (brackets, cable ties) to protect against damage and tearing.
Loctite® 243™ Direct mounting All oil filled perma NOVA come with an integrated oil retaining valve. They can be installed directly on a lubrication brush without the need for an additional oil valve. Insert for bracket G1/4 male x G1/4 female...
Page 8
4. Lubrication point, accessory parts and tubes / hoses must be pre-filled with lubricant. This enables the lubricant to immediately reach the lubrication point. Grease gun (101455) Hose with rotary joint, slide and hydraulic coupling for grease gun (110199) Tube prefill adapter 5.
Pressure testing Check counter pressure at lubrication point before installing the lubrication system to guarantee correct function. Most bearings require 0.5 - 2 bar pressure (without extension tubes / hoses). perma NOVA can be used for these lubrication points. perma STAR VARIO...
Page 10
(Caution: Observe accident prevention regulations). 5. Open stop valve. 6. Push SET button on perma STAR VARIO for approx. 10 seconds until PU lights up on display to trigger an additional discharge / purge. 7. Watch the pressure on the gauge during the additional discharge. If pressure exceeds 7.5 bar the lubrication system will shut off automatically.