    3.3.9 SMS/Voice Control ······························································································································ 45 3.3.9.1 SMS ··················································································································································· 45 3.3.9.2 Voice ·················································································································································· 49 3.3.9.3 Alarm via SMS ·································································································································· 50 3.3.10 Link Backup (Route Redundancy) ································································································· 51 P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 3 4.13 Can not power on ································································································································· 87 4.14 Sys log shows “connect script failed” ································································································ 87 4.15 RF-R586 Router is online, but cannot visit website. ······································································· 87 P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 4 5.7 WAN RJ45 PPPoE and Cellular Fail Over backup redundancy ···················································· 114 5.8 SMS Reboot/Cell UP/Cell Down control ··························································································· 118 5.9 PPTP client connection ······················································································································· 121 6 OBTAINING DOCUMENTS ···································································································································· 123 P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 5: Preparation Job Before Configuration

    1 Preparation job before configuration 1.1 Learn your router version and feature 1) RF-R586 series contains different version and option feature. Please learn it before using it. Notes: please be informed the following features are option. Please indicate with your orders.
  • Page 6: Prepare Sim Card And Working Condition

    4) Make sure the signal is good enough where you test or install the router. Weak signal will make the router no work. If you find your signal strength is not good, please contact us for high gain antenna. P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 7: Hardware Installation

    RF-R586 Series Industrial Grade Cellular Router Chapter 2 2 Hardware Installation This chapter mainly describes the appearance, model and function of RF-R586 series and how to install and set the configurations. 1. Overall Dimension 2. Accessories Description 3. Installment 2.1 Overall Dimension 2.2 The Ports...
  • Page 8 Antenna Connection Table (please refer the corresponding table to connect the antennas with your Router version) Feature ANT1 ANT2 ANT3 ANT4 Main Cellular ● Feature ANT1 ANT2 ANT3 ANT4 P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 9: Installment

    The installation and configuration should be done or supervise by qualified engineer. Attention: Do not install RF-R586 series or connect/disconnect its cable when it is power on. P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 10: Sim/Uim Card Installed

    Notes: Connection sequence should be accurate Cable’s insulating striping length 。 is about 7mm. (For safety, insulating striping length should be too long). Please refer to the P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 11 After giving the device a 1 sec low level, it will reboot.3 seconds, the device will restore factory settings General Purpose DIO0 General Purpose DIO1 Not connect P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 12: Grounding

    Please connect the antenna after you successfully connect to the cable. And then insert the valid SIM/UIM card and provide the power to the RF-R586 series via the cable. After provide the power to RF-R586, if the SYS LED starts to blink in a few seconds, that means the system start-up is normal;...
  • Page 13 Data transmission in Ethernet Ethernet connection abnormal Ethernet is connected VPN tunnel set-up VPN tunnel set-up failure or unactivated CELL Access to the Internet WIFI Enable Disable P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 14: Software Configuration

    3.2.1 Network Configuration of the Computer. The router default parameters as follow Default IP: 192.168.8.1, sub mask: 255.255.255.0. There are two ways to set the PC’s IP address. P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 15 Set the PC IP as 192.168.8.xxx (xxx = 2~254), subnet mask: 255.255.255.0, default gateway: 192.168.8.1, primary DNS: 192.168.8.1. Way 2) DHCP Choose “Obtain an IP address automatically” and “Obtain DNS server address automatically”. P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 16 IP address setting, and can refer to Chapter 4.9. 3.2.2 Log into Router Open the Web Browser, and type http://192.168.8.1 into the address field and P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 17 “Apply” button. If you type into the correct User Name and Password, you will get the access into the Router’s Web Management Page. P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 18: How To Configure Web

    RF-R586 Series Industrial Grade Cellular Router 3.3 How to configure web 3.3.1 Main Menu as below Picture P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 19: Operation Mode

    The wireless apcli interface is treated as WAN port and the wireless ap interface and the Ethernet ports are LAN ports. Network Address Translation Normally and default we select “Gateway mode”, and keep all other parameters as default. P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 20: Wan Settings

    Notes: the Cell Modem Type was marked on the back of the router. For example, it shows the following picture. RF-R586 is the router series name. And the EM820w Cell Modem is the Cell Modem name. P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 21 On Time: router dialup or offline with schedule. Totally supports 4 groups. MAC Clone Enable and disable the MAC clone function. Parameter Groups P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 22 Fill in the related parameters. And DO NOT FORGET TO CLICK “Add/Edit” button. Parameters Groups Name: you can fill in the name freely. But keep No Space between characters. P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 23 Notes: If you don’t know advance cell parameters very well, please keep default settings. Otherwise the router may not work. Click Advance Parameter Groups, Cell Modem Parameters Groups expand. 2 click to contract. P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 24: Cell Icmp Check

    10, the router will get LCP check every 10 seconds. Other parameters: user can disable or enable or define it. Warmly Reminding: do not forget to click Apply button after setting. 3.3.3.2 Cell ICMP Check P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 25: Ap Client Mode (Wifi Client)

    Set RF-R586 as an AP client, RF-R586 will connect the upper WiFi router or WiFi AP. Step1) RF-R586 web -- Operation Mode – Choose “AP Client”, and click apply button. Wait some time until the RF-R586 make the setting works. P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 26 Security Mode: choose correct one to match the WiFi router/AP you want to connect. Encryption Type: choose correct one to match the WiFi router/AP you want to connect. P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 27 Here please select the right channel the same with the upper WiFi Router/AP you want to connect. Then choose the same Channel in RF-R586 router as follows, Step4) Internet Settings – WAN P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 28: Wan - Pppoe (Xdsl)

    Notes: you may not see the WAN RJ45 connection status. But it will flash to fresh the status every 30 seconds. Or you can manually flash to fresh. Step 2) RF-R586 web – Operation Mode, choose “Gateway” mode P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 29 Set the Idle Time. PPPoE will be offline if the set idle time has no data transmission. Manual: need manually dialup. Click “Apply” button. Step 4) RF-R586 web – Status, it display the WAN IP once the PPPoE is online. P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 30: Wan - Static (Fixed Ip)

    Step 2) RF-R586 web – Operation Mode, choose “Gateway” mode Step 3) RF-R586 web – Internet Settings – WAN – WAN Connection Type, choose “STATIC (fixed IP)” P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 31: Wan - Dhcp (Auto Config)

    RF-R586 web – Status, it display the WAN IP once the STATIC (fixed IP) is online. 3.3.3.6 WAN – DHCP (Auto config) Set RF-R586 WAN via DHCP (Auto config), RF-R586 will connect the upper router via P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 32 WAN Connection Type: choose “DHCP (Auto config)” Click “Apply” button. Step 4) RF-R586 web – Status, it display the WAN IP once the DHCP (Auto config) is online. P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 33: Lan Settings

    RF-R586 Series Industrial Grade Cellular Router 3.3.4 LAN Settings P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 34: Router Gateway Ip

    Setting the LAN parameters, include IP address, sub mask, VLAN, DHCP, etc. 3.3.4.1 Router Gateway IP Default, the Router LAN IP is 192.168.8.1. If users want to modify it, please change the related parameters. P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 35: Mac Binding

    Default Gateway: manually change it after you modify the IP Address. 3.3.4.2 MAC binding RF-R586 Router supports 3 groups of MAC Binding. The parameter value format is as followed picture. P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 36: Dns Proxy

    This page shows the key routing table of this router. New Static Router This page is about how to set static routing function of the router. P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 37: Vpn

    Notes: the following VPN configuration manual may be out of date. We update the IPSec and PPTP configuration in another manual. Please refer to manual of “RF-R586_H820_VPN_Usermanual_Eng.pdf”. 3.3.7.1 IPSEC P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 38 IPsec name have to be written as DEV+equipment ID+name (DEV281250D52F2A1452.vpn1.com), and make sure both the client and server are inputing Client equipment ID. You can find RF-R586’s ID in the Status interface. P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 39 IPsec name have to be written as DEV+equipment ID+name(DEV281250D52F2A1452.vpn1.com), and make sure both the client and server are inputing Client equipment ID. You can find RF-R586’s ID in the Status interface. P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 40: Pptp

    536870912 set security-association lifetime seconds 43200 set transform-set vpnset set isakmp-profile jordan reverse-route crypto map COREVPN 26 ipsec-isakmp dynamic jordan 3.3.7.2 PPTP P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 41 MPPC: tick it or not depends on PPTP Server’s settings. Click “apply” button to activate the settings. The PPTP client will try to connect the PPTP Server automatically. See example of Chapter 5.8. P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 42: L2Tp

    RF-R586 Series Industrial Grade Cellular Router 3.3.7.3 L2TP L2TP feature works as Client only. 3.3.7.4 Tunnel Tunnel Feature The RF-R586 Tunnel feature supports two GRE. P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 43: Dtu Settings (Serial To Cellular Gateway Feature)

    RF-R586 Series Industrial Grade Cellular Router IP Tunnel Feature 3.3.8 DTU Settings (Serial to Cellular Gateway Feature) Notes: this feature is for RF-R586 with DTU option only. P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 44 Send heart beat: open or close heart beat. heart beat interval time: set interval time to send each heart beat heart beat information: define the content of heart beat P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 45: Sms/Voice Control

    Add id string to head: add an ID string in the data or heartbeat. 3.3.9 SMS/Voice Control Notes: this feature is for RF-R586 with SMS/Voice option only. 3.3.9.1 SMS Step 1) click “SMS/Voice” Step 2) Activate the SMS feature P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 46 Telephone number: Sender’s phone number input. Totally can input 10 groups. Number 1….10: input the dedicated sender’s phone number. Do not forget to Tick “SMS” Step 3) Define the SMS command P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 47 DIO Status Command: input the command for I/O port status. For SMS feature, please keep the parameter default. Step 4) Click button to save Note: P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 48 Number, the router will receive the “up” command, and it will be online. And in the System Log, we shall find a info as following marks. P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 49: Voice

    Notes: This feature may not work due to network compatibility or module modem. Step 1) enable voice feature Step 2) set the dedicated phone number for voice control P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 50: Alarm Via Sms

    3.3.9.3 Alarm via SMS With this feature, the Router will send SMS to pre-defined phone number for warning and alarm. Step 1) enable Alarm feature P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 51: Link Backup (Route Redundancy)

    0, the alarm feature will be unlocked, then the alarm feature starts work again. 3.3.10 Link Backup (Route Redundancy) P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 52 Check Interval Time(min): for example, set is as 2. Router check link live every 2 minutes. Used The Same Method: If set it as YES, WAN1/WAN2/WAN3 use same check IP or domain name from ALL WAN Check Method. P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 53 With this configuration, the router will work at DHCP mainly, and if DHCP is failed, it switches to cellular automatically after some time. And it will automatically switch to P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 54 With this configuration, the router will work at cellular mainly, and if cellular is failed, it switches to DHCP automatically after some time. And it will automatically switch to cellular when cellular is fixed. DHCP: here can be DHCP WiFi Client. P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 55: Gps

    Notes: for route fail over feature, please first make the main network and backup network both work before activate the fail over feature. 3.3.11 GPS Notes: GPS feature is for RF-R586 router with GPS option only. P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 56 Server port: fill in the correct destination server port GPS to Serial Settings serial baudrate: 9600/19200/38400/57600/115200bps for choice serial parity: none/odd/even for choice serial databits: 7/8 for choice P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 57: Wifi Wireless Settings

    1/2 for choice serial flow control: none/hardware/software for choice 3.3.12 WiFi Wireless Settings Notes: WiFi Feature is RF-R586 with WiFi only 3.3.12.1 Basic Wireless Settings P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 58 RF-R586 Series Industrial Grade Cellular Router P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 59: Wifi Advanced Settings

    Broadcast Network Name (SSID): Enable or Disable SSID broadcast. BSSID: indicates the MAC of WiFi Frequency (Channel): current working frequency and channel. 3.3.12.2 WiFi Advanced Settings P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 60: Wireless Security/Encryption Settings

    3.3.12.3 Wireless Security/Encryption Settings SSID choice: select the SSID you want to configure Security Mode: include Disable, OPENWEB, SHAREDWEB, WEBAUTO, WPA, WPA-PSK, WPA2, WPA2-PSK, wpa-psk/wpa2-psk, wpa1/wpa2, 802.1X. P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 61: Wds

    Disable: close the Access Policy. Allow: allow the assigned MAC enable to use WiFi Reject: refuse the assigned MAC enable to use WiFi 3.3.12.4 WDS 3.3.12.5 WPS 3.3.12.6 Station List P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 62: Statistics

    RF-R586 Series Industrial Grade Cellular Router 3.3.12.7 Statistics 3.3.13 Firewall 3.3.13.1 MAC/IP/Port Filter Settings P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 63: Port Forwarding (Virtual Server Settings)(Nat/Napt)

    Action: choose Accept or Drop Comment: input comment here Current MAC/IP/Port filtering rules in system It display the configured rules in this table. 3.3.13.2 Port Forwarding (Virtual Server Settings)(NAT/NAPT) P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 64: Dmz Host

    IP address: fill the IP address of forwarding. The first blank is for local IP address, the second blank is for port. Port Range: fill the Port of forwarding. 3.3.13.3 DMZ Host P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 65: System Security

    Except TCP port: disable or enable for TCP port Note: When DMZ host is settled, the computer is completely exposed to the external network; the firewall will not influence this host. 3.3.13.4 System Security P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 66: Content Filter Settings

    3.3.13.5 Content Filter Settings You can setup Content Fillter to restrict the improper content access, including Webs Content Settings, URL filter and Host Filter. Proxy/Java/Activex Filter P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 67 RF-R586 Series Industrial Grade Cellular Router Support Proxy, Java, ActiveX filter. Web URL Filter Fill in the URL for filter. Web Host Filter P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 68: Administration

    Select Web display language. Default is English. Can OEM other languages. WatchDog Web Management Port Settings Default port is 80, sometimes if the carrier/ISP block 80 port for remote incoming, can try to P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 69 Dynamic DNS Provider: choose the right DNS server provider. Supported server list. Account: fill in account info. Password: fill in password info. DDNS: fill in DDNS info. Example: P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 70: Router Web Port

    Please input the web port of the router. Normally we use 80 or 10000. Please re-power the router after changing the port number. 3.3.14.1.2 Language, password and NTP settings P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 71: Ddns Settings

    Dynamic DNS Provider: choose the right DNS server provider. Supported server list. Account: fill in account info. Password: fill in password info. DDNS: fill in DDNS info. Example: P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 72: Upload Firmware (Upgrade Firmware)

    But most of time it no need do this step unless RFoG guide or inform you to upload bootloader. 3.3.14.3 Settings Management P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 73: System Command

    Input related command at command area. Click “Apply” button to execute. The blank area will display infos. 3.3.14.5 System Log Remote System Log Settings RF-R586 Router support export the sys log into remote server. P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 74: Statistics

    RF-R586 Series Industrial Grade Cellular Router Local System Log 3.3.14.6 Statistics P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 75 RF-R586 Series Industrial Grade Cellular Router P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 76: Reboot

    However, Reboot Feature will double ensure the router to be more stable and reliable. RF-R586 Router support three types of Reboot Feature. Reboot AT Time Settings P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 77: Status

    Users can define the exact time to reboot for everyday. Reboot AT Time Settings Users can set timer to reboot. Reboot AT Time Settings Manually click “Reboot” button to reboot immediately. 3.3.14.8 Status P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 78 RF-R586 Series Industrial Grade Cellular Router From this page you can see the Router’s basic running state. Ethernet Port Status P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 79 Signal: reveals the current network state of 2G/3G. 0 and 99 mean no signal. Cell state: indicates the cellular is online or offline Internet Configurations Connected Type: indicates the selected WAN type. P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 80: Snmp (For Version With Snmp Only)

    Notes: SNMP feature is for RF-R586 Router with SNMP option only. RF-R586 router web page – Internet Settings – SNMP Fill in related parameters in the screen like follows, P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 81 Encryption Password: fill in the right one. Click “Apply” button and reboot the router. Here list the most important OID: 1.3.6.1.4.1.2021.255.4.1.2.9.103.101.116.95.109.111.100.101.109.1 (read module modem model) 1.3.6.1.4.1.2021.255.4.1.2.10.103.101.116.95.117.112.116.105.109.101.1 P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 82 RF-R586 Series Industrial Grade Cellular Router (system running time) 1.3.6.1.4.1.2021.255.4.1.2.12.103.101.116.95.109.101.109.95.102.114.101.101.1 (memory capacity) 1.3.6.1.4.1.2021.255.4.1.2.15.103.101.116.95.99.101.108.108.95.115.116.97.116.117.115.1 (3G network status) 1.3.6.1.4.1.2021.255.4.1.2.15.103.101.116.95.108.50.116.112.95.115.116.97.116.117.115.1 (pptp status) 1.3.6.1.4.1.2021.255.4.1.2.15.103.101.116.95.112.112.116.112.95.115.116.97.116.117.115.1 (l2tp status) List client side’s picture as follows, P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 83: Faq

    Try to scrap the sim card slot and make it clean. 4.3 Signal Strength has right number, but cannot dialup Try to check the WAN port setting is correct. 4.4 Signal Strength shows 99 P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 84: The Router Cannot Be Remote Web Visited

    2) Double check PC network card IP is correct configured. Please refer to Chapter 3.2 3) Try to disable the PC network card, and re-enable it. P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 85: Cannot Connect Rf-R586 Wifi

    RF-R586 router will automatically load default. 4.11 Can Connect RF-R586 WiFi via Manual IP but cannot via DHCP 1) Try to disable the Device’s network card, and re-enable it. P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 86: Cannot Get Cell Wan Ip

    Try to move to another site to test. Or try to test with another ISP/Carrier SIM card Module modem is defeated Send back the unit to factory for repair P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 87: Can Not Power On

    Solution: 1. Check if the power adapter connector is loose from the router. 2. Try to replace a power adapter. RF-R586 series router uses 9V1A or 9V2A or 12V1A or 12V1A or 12V2A power adapter with 2.5mm connector 3. Router hardware defeated. Send back to factory for check or repair.
  • Page 88: Port Forwarding Not Working

    1) Get another SIM card from another ISP to test. 2) Ask the Vodafone ISP to unlimit two Vadafone SIM's communication. 4.18 Can’t open device /dev/ttyUSBx. Problem: Status page shows “Can’t open device /dev/ttyUSBx”. P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 89: Pptp Is On, But Cannot Be Through To Pptp Server

    4.19 PPTP is on, but cannot be through to PPTP Server Issue and phenomenon: in web status page, the PPTP shows “on”, but try to ping PPTP Server, cannot get through. Solution: P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 90 RF-R586 Default Gateway to 192.168.1.1 or 192.168.0.1 meanwhile. 3) with the following steps, normally it can solve the issue. Otherwise, please contact RFoG Sales or Support. P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 91: Test Samples

    RF-R586-c 2. Connect PC with RF-R586-s with RJ45 cable. 3. At RF-R586-s and RF-R586-c, make sure the DHCP service from both routers are working. At RF-R586-s, P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 92 “3G Router” to test first) And write down the “Frequency (Channel)” and “Extension Channel”. Remember it and we shall use this value at RF-R586-c. P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 93 6. Try to connect the RF-R586-s WiFi via your Laptop/PC. If can work, then go to step 7. 7. Connect PC with RF-R586-c with RJ45 cable. 8. at RF-R586-c, “Operation Mode”, choose “AP client”, and click “Apply” P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 94 9. at RF-R586-c, “Wireless Settings—AP Client—SSID”, here input the correct one. Here the value is from the RF-R586-s. 10. at RF-R586-c, “Frequency (Channel)” and “Extension Channel” should be the same as RF-R586-s P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 95 “Apply” button. 12. Then check RF-R586-c, “Administration--Status”, if it shows “Operation Mode” as “AP client Mode” and get “WAN IP Address”, that means the test is working. P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 96: Gps Feature (For Version With Gps Feature Only)

    Note: the test is simulation test to approve and show the feature. Please make it work in your real application. Here we run a TCP server tool as the GPS TCP server. Step1: configure the GPS feature of the router. P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 97 And we make a DMZ or NAT for this IP and port from the local router connected to internet with IP 27.38.13.57. And in the router GPS configuration, we fill in “27.38.13.57” and port “10001”. P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 98 Once the link is okay, it will show the following similar screen. If the route doesn’t get the satellite, it appears and updates the GPS module info from the router to the TCP GPS server. P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 99: Port Forwarding (Nat, Napt) Test

    80 port. Then check with your ISP which ports are open for use. Then re-try the port forwarding feature. Step 1) make RF-R586 router to be online. P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 100 Connect the PC to RF-R586 router LAN port via RJ45 cable. And it gets an IP 10.10.10.100. At the PC, run TCP&UDP_debug software (If you have no such software, require to get from us). P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 101 Step 4) here we take another PC to be as a TCP client. This PC is with internet in another network. Run TCPUDP_debug software tool, choose Client Mode, P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 102 Then check the DestIP, DestPort and Type, and click Connect button to link. Once the link is done, at the Server PC’s side, it shows the following picture, which indicates the link is created. P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 103 Step 5) Test the link for sending and receiving At client PC, type “test from client to server”, and click Send button. At the server PC, it will receive the info the client PC. P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 104 At Server PC, type “reply from server to client”, and click Send button. At the client PC side, it will receive the related info from server PC side. P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 105: Remote Web Login

    With this result, it indicates the port forwarding is working. 5.4 Remote Web Login Step 1) make RF-R586 router to be online and get a public WAN IP. P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 106 PC. So we cannot make the remote visit of the RF-R586 router web. Let’s get a public IP for RF-R586 router first. Here we change another sim card to test. P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 107 RF-R586 router gets a WAN IP 183.43.55.249, which is a public IP, and can ping though. Step 2) Make sure the “Remote Management” feature is activated. P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 108: Wan Rj45 Static (Fixed Ip) And Cellular Fail Over Backup Redundancy

    Please connect the RJ45 WAN port and the upper Router LAN RJ45 port via RJ45 cable. The RF-R586 WAN LED should be on. Step 1) log into the RF-R586 router web. Step 2) Internet Settings – Route Fail Over P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 109 Configure the Cell WAN parameters. Please make sure RF-R586 can be Cell online after this configuration. Otherwise the fail over feature will not work in redundancy P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 110 RF-R586 Series Industrial Grade Cellular Router Step 4) Internet Settings – WAN – WAN Connection Type – STATIC (fixed IP) Configure the STATIC (fixed IP), P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 111 If main line failed, it will switch to Cell as secondary line. And if STATIC WAN RJ45 resume to work, it will switch from Cell line to STATIC WAN RJ45 line. The following page indicated the Static fixed IP is working. P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 112: Wan Rj45 Dhcp And Cellular Fail Over Backup Redundancy

    Checking Method: fill in a public IP address that can be ping through. With the above configuration, the router will try to ping IP 74. 125.71.138 and if cannot be through for 3 P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 113 Step 4) Internet Settings – WAN – WAN Connection Type – DHCP (Auto config) Choose “DHCP (Auto config)” at WAN Connection Type, and click “Apply” button P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 114: Wan Rj45 Pppoe And Cellular Fail Over Backup Redundancy

    Please connect the RJ45 WAN port and the ADSL modem RJ45 port via RJ45 cable. The RF-R586 WAN LED should be on. Step 1) log into the RF-R586 router web. Step 2) Internet Settings – Route Fail Over P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 115 Configure the Cell WAN parameters. Please make sure RF-R586 can be Cell online after this configuration. Otherwise the fail over feature will not work in redundancy P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 116 RF-R586 Series Industrial Grade Cellular Router Step 4) Internet Settings – WAN – WAN Connection Type – PPPoE (ADSL) P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 117 If main line failed, it will switch to Cell as secondary line. And if WAN RJ45 PPPoE resume to work, it will switch from Cell line to WAN RJ45 PPPoE line. The following page indicated the PPPoE is working. P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 118: Sms Reboot/Cell Up/Cell Down Control

    Once the PPPoE (ADSL) is failed, RF-R586 will switch to cellular automatically as follows, 5.8 SMS Reboot/Cell UP/Cell Down control Step 1) follow Chapter 3.3.9 to configure the SMS feature. We configure it as follows, P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 119 "received index=0 msg (celldown) from (13798257916) !" The Router CELL will be offline, and WAN IP will be none as followed status. P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 120 From sender’s phone number 13798257916, send "cellstatus" to router sim/uim card number. At the router "System Log", there is info similar " received index=0 msg (cellstatus) from (13798257916) !". The router will P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 121: Pptp Client Connection

    Step 1) make the RF-R586 router working online. Step 2) Fill in the PPTP parameters as follows, Step 3) check if the PPTP is connected. Router Web – Status, P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 122 RF-R586 Series Industrial Grade Cellular Router Step 4) Try to check if can be through with PPTP Server. P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466...
  • Page 123: Obtaining Documents

    The results obtained in other operating environment may vary. THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROVIDED ON AN ”AS IS” BASIS. In no event will RFoG be liable for damages arising directly from any use of the information contained in this document.