Relay Terminal; Operation - Desco TB-3086 Technical Bulletin

Full-time continuous monitor
Table of Contents

Advertisement

Relay Terminal

The Full-Time Continuous Monitor features a relay
terminal that can be integrated with electronic locks,
lights, buzzers, etc. The relay will activate when a failure
is reported by the Full-Time Continuous Monitor.
Contact Form
Maximum Switching Power
Maximum Switching Voltage 220 VDC, 250 VAC
Maximum Switching Current 2 A
Maximum Carrying Current
Figure 12. Relay terminal contacts
10 mm Snap Adapters
The 19322 Full-Time Continuous Monitor includes an
interchangeable 10 mm park snap and 10 mm banana
jack adapter for operators who use wrist cords with
10 mm terminations. Use the park snap's knurled rim
to unscrew the 4 mm park snap from the monitor and
install the 10 mm park snap to the monitor. Plug the 10
mm operator jack adapter into the monitor's operator
jack.
Figure 13. Installing the 10 mm snap adapters to the
19322 Full-Time Continuous Monitor
Test Equipment Depot - 800.517.8431 - 5 Commonwealth Ave, Woburn,MA 01801 - TestEquipmentDepot.com
TB-3086 Page 6 of 8
2 Form C
60 W, 125 VAC
2 A
NC
C
NO

Operation

1. Fit the wristband snugly onto the wrist.
2. Snap the wrist cord to the wristband.
3.
Plug the wrist cord into the operator jack. The green
operator LED will illuminate. This indicates that the
operator is properly grounded.
If this does not happen, examine the wrist cord for
4.
continuity or damage and the wristband to ensure
that it fits securely. If you have dry skin, apply an
approved dissipative hand lotion such as
Reztore® ESD Hand Lotion.
5. When leaving the workstation, first touch the
monitor's park switch or park snap. The monitor's
audible alarm will disable for approximately 8
seconds. Use this time to disconnect the wrist cord
from the wristband and attach it to the park snap
without sounding a false alarm.
6. Upon returning to the workstation and disconnecting
the wrist cord from the park snap, the monitor will
provide approximately 8 seconds for the operator to
reconnect the wrist cord to a worn wristband before
sounding the monitor's alarm.
Figure 14. Using the Full-Time Continuous Monitor when
mounted underneath a workbench tabletop